Modifications proposed to the concepts of structural protection

In this paper we show that the scale of damage in buildings with steel reinforcement, due to direct lightning strikes, is insignificantly small compared to the lightning effects on buildings and structures with no such steel reinforcement. The observed small-scale damages are also confined only to t...

Full description

Bibliographic Details
Main Author: Gomes, Chandima
Format: Conference or Workshop Item
Language:English
Published: IEEE 2010
Online Access:http://psasir.upm.edu.my/id/eprint/45593/1/Modifications%20proposed%20to%20the%20concepts%20of%20structural%20protection.pdf
_version_ 1796974563001630720
author Gomes, Chandima
author_facet Gomes, Chandima
author_sort Gomes, Chandima
collection UPM
description In this paper we show that the scale of damage in buildings with steel reinforcement, due to direct lightning strikes, is insignificantly small compared to the lightning effects on buildings and structures with no such steel reinforcement. The observed small-scale damages are also confined only to the point of strike. A large number of such cases have been observed in Sri Lanka and Malaysia. The fact that almost all these damaged structures, observed in this study, have a steel reinforcement structure, but not verified to be in compliance with the specifications in lEC 62305-3 (2006) for it to act as down conducting system, prompted us to re-think regarding the specifications. Such specifications are difficult to be achieved in practice and also not applicable to buildings that have been already constructed. The recommendations prevents the engineers from using the steel reinforcement as the down conductor in many cases; a fact that leads to either non-installation of LP systems or adopting non-conventional systems which are convenient to be installed. In both cases, a noteworthy advantage that could have obtained by using the steel reinforcement is lost. Use of the steel reinforcement as the down conducting system, which is integrated to a properly designed air-termination system could have prevented even the small-scale damage occurred at the attachment point. Hence, we strongly recommend revising the relevant recommendations in the standards so that a mass public will be benefited. In the absence of such relaxation of the existing guidelines the manufacturers and proponents of nonconventional lightning protection systems enjoy an undue advantage in promoting their technology.
first_indexed 2024-03-06T08:58:51Z
format Conference or Workshop Item
id upm.eprints-45593
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T08:58:51Z
publishDate 2010
publisher IEEE
record_format dspace
spelling upm.eprints-455932020-08-07T02:27:07Z http://psasir.upm.edu.my/id/eprint/45593/ Modifications proposed to the concepts of structural protection Gomes, Chandima In this paper we show that the scale of damage in buildings with steel reinforcement, due to direct lightning strikes, is insignificantly small compared to the lightning effects on buildings and structures with no such steel reinforcement. The observed small-scale damages are also confined only to the point of strike. A large number of such cases have been observed in Sri Lanka and Malaysia. The fact that almost all these damaged structures, observed in this study, have a steel reinforcement structure, but not verified to be in compliance with the specifications in lEC 62305-3 (2006) for it to act as down conducting system, prompted us to re-think regarding the specifications. Such specifications are difficult to be achieved in practice and also not applicable to buildings that have been already constructed. The recommendations prevents the engineers from using the steel reinforcement as the down conductor in many cases; a fact that leads to either non-installation of LP systems or adopting non-conventional systems which are convenient to be installed. In both cases, a noteworthy advantage that could have obtained by using the steel reinforcement is lost. Use of the steel reinforcement as the down conducting system, which is integrated to a properly designed air-termination system could have prevented even the small-scale damage occurred at the attachment point. Hence, we strongly recommend revising the relevant recommendations in the standards so that a mass public will be benefited. In the absence of such relaxation of the existing guidelines the manufacturers and proponents of nonconventional lightning protection systems enjoy an undue advantage in promoting their technology. IEEE 2010 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/45593/1/Modifications%20proposed%20to%20the%20concepts%20of%20structural%20protection.pdf Gomes, Chandima (2010) Modifications proposed to the concepts of structural protection. In: 30th International Conference on Lightning Protection (ICLP 2010), 13-17 Sept. 2010, Cagliari, Italy. (pp. 1-6). 10.1109/ICLP.2010.7845945
spellingShingle Gomes, Chandima
Modifications proposed to the concepts of structural protection
title Modifications proposed to the concepts of structural protection
title_full Modifications proposed to the concepts of structural protection
title_fullStr Modifications proposed to the concepts of structural protection
title_full_unstemmed Modifications proposed to the concepts of structural protection
title_short Modifications proposed to the concepts of structural protection
title_sort modifications proposed to the concepts of structural protection
url http://psasir.upm.edu.my/id/eprint/45593/1/Modifications%20proposed%20to%20the%20concepts%20of%20structural%20protection.pdf
work_keys_str_mv AT gomeschandima modificationsproposedtotheconceptsofstructuralprotection