Thermal diffusivity measurement for p-Si and Ag/p-Si by photoacoustic technique
Thermal diffusivity (TD) of p-Si and Ag/p-Si samples were measured by photoacoustic technique using open photoacoustic cell (OPC). The samples were annealed by heating them at 960, 1050, 1200, and 1300 °C for 3 h in air. The thermal diffusivity of Ag-coated samples was obtained by fitting the photoa...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Springer New York
2015
|
Online Access: | http://psasir.upm.edu.my/id/eprint/46723/1/Thermal%20diffusivity%20measurement%20for%20p-Si%20and%20Agp-Si%20by%20photoacoustic%20technique.pdf |
_version_ | 1825929735960526848 |
---|---|
author | Hussein, Mohammed Jabbar Mat Yunus, Wan Mahmood Mohamed Kamari, Halimah Zakaria, Azmi |
author_facet | Hussein, Mohammed Jabbar Mat Yunus, Wan Mahmood Mohamed Kamari, Halimah Zakaria, Azmi |
author_sort | Hussein, Mohammed Jabbar |
collection | UPM |
description | Thermal diffusivity (TD) of p-Si and Ag/p-Si samples were measured by photoacoustic technique using open photoacoustic cell (OPC). The samples were annealed by heating them at 960, 1050, 1200, and 1300 °C for 3 h in air. The thermal diffusivity of Ag-coated samples was obtained by fitting the photoacoustic experimental data to the thermally thick equation for Rosencwaig and Gersho (RG) theory. For the single layer samples, the thermal diffusivity can be obtained by fitting as well as by obtaining the critical frequency f c . In this study, the thermal diffusivity of the p-Si samples increased with increasing the annealing temperature. The thermal diffusivity of the Ag/p-Si samples, after reaching the maximum value of about 2.73 cm2/s at a temperature of 1200 °C, decreased due to the silver complete melt in the surface of the silicon. |
first_indexed | 2024-03-06T09:01:04Z |
format | Article |
id | upm.eprints-46723 |
institution | Universiti Putra Malaysia |
language | English |
last_indexed | 2024-03-06T09:01:04Z |
publishDate | 2015 |
publisher | Springer New York |
record_format | dspace |
spelling | upm.eprints-467232018-04-23T01:14:45Z http://psasir.upm.edu.my/id/eprint/46723/ Thermal diffusivity measurement for p-Si and Ag/p-Si by photoacoustic technique Hussein, Mohammed Jabbar Mat Yunus, Wan Mahmood Mohamed Kamari, Halimah Zakaria, Azmi Thermal diffusivity (TD) of p-Si and Ag/p-Si samples were measured by photoacoustic technique using open photoacoustic cell (OPC). The samples were annealed by heating them at 960, 1050, 1200, and 1300 °C for 3 h in air. The thermal diffusivity of Ag-coated samples was obtained by fitting the photoacoustic experimental data to the thermally thick equation for Rosencwaig and Gersho (RG) theory. For the single layer samples, the thermal diffusivity can be obtained by fitting as well as by obtaining the critical frequency f c . In this study, the thermal diffusivity of the p-Si samples increased with increasing the annealing temperature. The thermal diffusivity of the Ag/p-Si samples, after reaching the maximum value of about 2.73 cm2/s at a temperature of 1200 °C, decreased due to the silver complete melt in the surface of the silicon. Springer New York 2015 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/46723/1/Thermal%20diffusivity%20measurement%20for%20p-Si%20and%20Agp-Si%20by%20photoacoustic%20technique.pdf Hussein, Mohammed Jabbar and Mat Yunus, Wan Mahmood and Mohamed Kamari, Halimah and Zakaria, Azmi (2015) Thermal diffusivity measurement for p-Si and Ag/p-Si by photoacoustic technique. Brazilian Journal Physics, 45 (5). pp. 518-524. ISSN 0103-9733; ESSN: 1678-4448 http://www.springer.com/physics/journal/13538 10.1007/s13538-015-0343-x |
spellingShingle | Hussein, Mohammed Jabbar Mat Yunus, Wan Mahmood Mohamed Kamari, Halimah Zakaria, Azmi Thermal diffusivity measurement for p-Si and Ag/p-Si by photoacoustic technique |
title | Thermal diffusivity measurement for p-Si and Ag/p-Si by photoacoustic technique |
title_full | Thermal diffusivity measurement for p-Si and Ag/p-Si by photoacoustic technique |
title_fullStr | Thermal diffusivity measurement for p-Si and Ag/p-Si by photoacoustic technique |
title_full_unstemmed | Thermal diffusivity measurement for p-Si and Ag/p-Si by photoacoustic technique |
title_short | Thermal diffusivity measurement for p-Si and Ag/p-Si by photoacoustic technique |
title_sort | thermal diffusivity measurement for p si and ag p si by photoacoustic technique |
url | http://psasir.upm.edu.my/id/eprint/46723/1/Thermal%20diffusivity%20measurement%20for%20p-Si%20and%20Agp-Si%20by%20photoacoustic%20technique.pdf |
work_keys_str_mv | AT husseinmohammedjabbar thermaldiffusivitymeasurementforpsiandagpsibyphotoacoustictechnique AT matyunuswanmahmood thermaldiffusivitymeasurementforpsiandagpsibyphotoacoustictechnique AT mohamedkamarihalimah thermaldiffusivitymeasurementforpsiandagpsibyphotoacoustictechnique AT zakariaazmi thermaldiffusivitymeasurementforpsiandagpsibyphotoacoustictechnique |