Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line

Lightning has been a major concern to the power system researchers because it can cause damage to the connected electrical equipment and transmission failure. One study carried out is that where the level of voltage at a substation is observed following a backflashover analysis on a transmission lin...

Full description

Bibliographic Details
Main Authors: Sardi, Junainah, Ab Kadir, Mohd Zainal Abidin, Wan Ahmad, Wan Fatinhamamah, Hizam, Hashim, Mohamed Rawi, Iryani, Ahmad, A.
Format: Conference or Workshop Item
Language:English
Published: IEEE 2008
Online Access:http://psasir.upm.edu.my/id/eprint/47665/1/Backflashover%20analysis%20for%20132%20kV%20Kuala%20Krai-Gua%20Musang%20transmission%20line.pdf
_version_ 1796974831750610944
author Sardi, Junainah
Ab Kadir, Mohd Zainal Abidin
Wan Ahmad, Wan Fatinhamamah
Hizam, Hashim
Mohamed Rawi, Iryani
Ahmad, A.
author_facet Sardi, Junainah
Ab Kadir, Mohd Zainal Abidin
Wan Ahmad, Wan Fatinhamamah
Hizam, Hashim
Mohamed Rawi, Iryani
Ahmad, A.
author_sort Sardi, Junainah
collection UPM
description Lightning has been a major concern to the power system researchers because it can cause damage to the connected electrical equipment and transmission failure. One study carried out is that where the level of voltage at a substation is observed following a backflashover analysis on a transmission line. Sample of worst case transmission line was taken from Tenaga National Berhad, which is 132 kV Kuala Krai-Gua Musang line for the purpose of simulation using PSCAD software. An integral part of this study is the model of transmission line components such as insulator coordination gap flashover, tower model, nonlinear current dependent resistance as footing model. All models are verified by accurate analysis of previous researchers. Results were analyzed and influences of line parameters to backflashover rate were discussed. Practical recommendations and conclusions based on the results are made for an improvement in the lightning performance of high voltage transmission line.
first_indexed 2024-03-06T09:02:45Z
format Conference or Workshop Item
id upm.eprints-47665
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T09:02:45Z
publishDate 2008
publisher IEEE
record_format dspace
spelling upm.eprints-476652016-07-14T02:24:01Z http://psasir.upm.edu.my/id/eprint/47665/ Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line Sardi, Junainah Ab Kadir, Mohd Zainal Abidin Wan Ahmad, Wan Fatinhamamah Hizam, Hashim Mohamed Rawi, Iryani Ahmad, A. Lightning has been a major concern to the power system researchers because it can cause damage to the connected electrical equipment and transmission failure. One study carried out is that where the level of voltage at a substation is observed following a backflashover analysis on a transmission line. Sample of worst case transmission line was taken from Tenaga National Berhad, which is 132 kV Kuala Krai-Gua Musang line for the purpose of simulation using PSCAD software. An integral part of this study is the model of transmission line components such as insulator coordination gap flashover, tower model, nonlinear current dependent resistance as footing model. All models are verified by accurate analysis of previous researchers. Results were analyzed and influences of line parameters to backflashover rate were discussed. Practical recommendations and conclusions based on the results are made for an improvement in the lightning performance of high voltage transmission line. IEEE 2008 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/47665/1/Backflashover%20analysis%20for%20132%20kV%20Kuala%20Krai-Gua%20Musang%20transmission%20line.pdf Sardi, Junainah and Ab Kadir, Mohd Zainal Abidin and Wan Ahmad, Wan Fatinhamamah and Hizam, Hashim and Mohamed Rawi, Iryani and Ahmad, A. (2008) Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line. In: 2008 IEEE 2nd International Power and Energy Conference (PECon 2008), 1-3 Dec. 2008, Johor Bahru, Malaysia. (pp. 1494-1497). 10.1109/PECON.2008.4762716
spellingShingle Sardi, Junainah
Ab Kadir, Mohd Zainal Abidin
Wan Ahmad, Wan Fatinhamamah
Hizam, Hashim
Mohamed Rawi, Iryani
Ahmad, A.
Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line
title Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line
title_full Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line
title_fullStr Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line
title_full_unstemmed Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line
title_short Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line
title_sort backflashover analysis for 132 kv kuala krai gua musang transmission line
url http://psasir.upm.edu.my/id/eprint/47665/1/Backflashover%20analysis%20for%20132%20kV%20Kuala%20Krai-Gua%20Musang%20transmission%20line.pdf
work_keys_str_mv AT sardijunainah backflashoveranalysisfor132kvkualakraiguamusangtransmissionline
AT abkadirmohdzainalabidin backflashoveranalysisfor132kvkualakraiguamusangtransmissionline
AT wanahmadwanfatinhamamah backflashoveranalysisfor132kvkualakraiguamusangtransmissionline
AT hizamhashim backflashoveranalysisfor132kvkualakraiguamusangtransmissionline
AT mohamedrawiiryani backflashoveranalysisfor132kvkualakraiguamusangtransmissionline
AT ahmada backflashoveranalysisfor132kvkualakraiguamusangtransmissionline