Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line
Lightning has been a major concern to the power system researchers because it can cause damage to the connected electrical equipment and transmission failure. One study carried out is that where the level of voltage at a substation is observed following a backflashover analysis on a transmission lin...
Main Authors: | , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IEEE
2008
|
Online Access: | http://psasir.upm.edu.my/id/eprint/47665/1/Backflashover%20analysis%20for%20132%20kV%20Kuala%20Krai-Gua%20Musang%20transmission%20line.pdf |
_version_ | 1796974831750610944 |
---|---|
author | Sardi, Junainah Ab Kadir, Mohd Zainal Abidin Wan Ahmad, Wan Fatinhamamah Hizam, Hashim Mohamed Rawi, Iryani Ahmad, A. |
author_facet | Sardi, Junainah Ab Kadir, Mohd Zainal Abidin Wan Ahmad, Wan Fatinhamamah Hizam, Hashim Mohamed Rawi, Iryani Ahmad, A. |
author_sort | Sardi, Junainah |
collection | UPM |
description | Lightning has been a major concern to the power system researchers because it can cause damage to the connected electrical equipment and transmission failure. One study carried out is that where the level of voltage at a substation is observed following a backflashover analysis on a transmission line. Sample of worst case transmission line was taken from Tenaga National Berhad, which is 132 kV Kuala Krai-Gua Musang line for the purpose of simulation using PSCAD software. An integral part of this study is the model of transmission line components such as insulator coordination gap flashover, tower model, nonlinear current dependent resistance as footing model. All models are verified by accurate analysis of previous researchers. Results were analyzed and influences of line parameters to backflashover rate were discussed. Practical recommendations and conclusions based on the results are made for an improvement in the lightning performance of high voltage transmission line. |
first_indexed | 2024-03-06T09:02:45Z |
format | Conference or Workshop Item |
id | upm.eprints-47665 |
institution | Universiti Putra Malaysia |
language | English |
last_indexed | 2024-03-06T09:02:45Z |
publishDate | 2008 |
publisher | IEEE |
record_format | dspace |
spelling | upm.eprints-476652016-07-14T02:24:01Z http://psasir.upm.edu.my/id/eprint/47665/ Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line Sardi, Junainah Ab Kadir, Mohd Zainal Abidin Wan Ahmad, Wan Fatinhamamah Hizam, Hashim Mohamed Rawi, Iryani Ahmad, A. Lightning has been a major concern to the power system researchers because it can cause damage to the connected electrical equipment and transmission failure. One study carried out is that where the level of voltage at a substation is observed following a backflashover analysis on a transmission line. Sample of worst case transmission line was taken from Tenaga National Berhad, which is 132 kV Kuala Krai-Gua Musang line for the purpose of simulation using PSCAD software. An integral part of this study is the model of transmission line components such as insulator coordination gap flashover, tower model, nonlinear current dependent resistance as footing model. All models are verified by accurate analysis of previous researchers. Results were analyzed and influences of line parameters to backflashover rate were discussed. Practical recommendations and conclusions based on the results are made for an improvement in the lightning performance of high voltage transmission line. IEEE 2008 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/47665/1/Backflashover%20analysis%20for%20132%20kV%20Kuala%20Krai-Gua%20Musang%20transmission%20line.pdf Sardi, Junainah and Ab Kadir, Mohd Zainal Abidin and Wan Ahmad, Wan Fatinhamamah and Hizam, Hashim and Mohamed Rawi, Iryani and Ahmad, A. (2008) Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line. In: 2008 IEEE 2nd International Power and Energy Conference (PECon 2008), 1-3 Dec. 2008, Johor Bahru, Malaysia. (pp. 1494-1497). 10.1109/PECON.2008.4762716 |
spellingShingle | Sardi, Junainah Ab Kadir, Mohd Zainal Abidin Wan Ahmad, Wan Fatinhamamah Hizam, Hashim Mohamed Rawi, Iryani Ahmad, A. Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line |
title | Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line |
title_full | Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line |
title_fullStr | Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line |
title_full_unstemmed | Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line |
title_short | Backflashover analysis for 132 kV Kuala Krai-Gua Musang transmission line |
title_sort | backflashover analysis for 132 kv kuala krai gua musang transmission line |
url | http://psasir.upm.edu.my/id/eprint/47665/1/Backflashover%20analysis%20for%20132%20kV%20Kuala%20Krai-Gua%20Musang%20transmission%20line.pdf |
work_keys_str_mv | AT sardijunainah backflashoveranalysisfor132kvkualakraiguamusangtransmissionline AT abkadirmohdzainalabidin backflashoveranalysisfor132kvkualakraiguamusangtransmissionline AT wanahmadwanfatinhamamah backflashoveranalysisfor132kvkualakraiguamusangtransmissionline AT hizamhashim backflashoveranalysisfor132kvkualakraiguamusangtransmissionline AT mohamedrawiiryani backflashoveranalysisfor132kvkualakraiguamusangtransmissionline AT ahmada backflashoveranalysisfor132kvkualakraiguamusangtransmissionline |