On the bending effects of a copper-type down conductor

Down-conductor is part of critical component in the external Lightning Protection System (LPS) as to divert the lightning current from the air termination to the earth termination system of protected structure. In this paper, numerical analysis approach incorporating the effect of copper conductor b...

Full description

Bibliographic Details
Main Authors: Mohd Ariffen, Amizah, Ab Kadir, Mohd Zainal Abidin, Gomes, Chandima, Jasni, Jasronita, Izadi, Mahdi
Format: Conference or Workshop Item
Language:English
Published: IEEE 2014
Online Access:http://psasir.upm.edu.my/id/eprint/48166/1/On%20the%20bending%20effects%20of%20a%20copper-type%20down%20conductor.pdf
_version_ 1825929950355521536
author Mohd Ariffen, Amizah
Ab Kadir, Mohd Zainal Abidin
Gomes, Chandima
Jasni, Jasronita
Izadi, Mahdi
author_facet Mohd Ariffen, Amizah
Ab Kadir, Mohd Zainal Abidin
Gomes, Chandima
Jasni, Jasronita
Izadi, Mahdi
author_sort Mohd Ariffen, Amizah
collection UPM
description Down-conductor is part of critical component in the external Lightning Protection System (LPS) as to divert the lightning current from the air termination to the earth termination system of protected structure. In this paper, numerical analysis approach incorporating the effect of copper conductor bending angle under current transient and voltage is utilized. Various angles of copper conductor will be synthesized following a simplified and generic, but meticulous, model based on the manufacturer's datasheet specification which is normally used. The fields were analyzed and the results were discussed in comparison with the MS IEC 62305-3 standard accordingly. In this case, the cross-sectional area of down-conductor was selected based on the accessible type produced by various manufacturers as proposed by the MS IEC 62305-3 standard for a critical study. This study presents the optimum angle of down-conductor with a view to develop a practical approach and to set the down-conductors in a confined area locations of a building.
first_indexed 2024-03-06T09:04:14Z
format Conference or Workshop Item
id upm.eprints-48166
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T09:04:14Z
publishDate 2014
publisher IEEE
record_format dspace
spelling upm.eprints-481662016-08-03T08:08:53Z http://psasir.upm.edu.my/id/eprint/48166/ On the bending effects of a copper-type down conductor Mohd Ariffen, Amizah Ab Kadir, Mohd Zainal Abidin Gomes, Chandima Jasni, Jasronita Izadi, Mahdi Down-conductor is part of critical component in the external Lightning Protection System (LPS) as to divert the lightning current from the air termination to the earth termination system of protected structure. In this paper, numerical analysis approach incorporating the effect of copper conductor bending angle under current transient and voltage is utilized. Various angles of copper conductor will be synthesized following a simplified and generic, but meticulous, model based on the manufacturer's datasheet specification which is normally used. The fields were analyzed and the results were discussed in comparison with the MS IEC 62305-3 standard accordingly. In this case, the cross-sectional area of down-conductor was selected based on the accessible type produced by various manufacturers as proposed by the MS IEC 62305-3 standard for a critical study. This study presents the optimum angle of down-conductor with a view to develop a practical approach and to set the down-conductors in a confined area locations of a building. IEEE 2014 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/48166/1/On%20the%20bending%20effects%20of%20a%20copper-type%20down%20conductor.pdf Mohd Ariffen, Amizah and Ab Kadir, Mohd Zainal Abidin and Gomes, Chandima and Jasni, Jasronita and Izadi, Mahdi (2014) On the bending effects of a copper-type down conductor. In: 2014 International Conference on Lightning Protection (ICLP), 11-18 Oct. 2014, Shanghai, China. (pp. 927-935). 10.1109/ICLP.2014.6973256
spellingShingle Mohd Ariffen, Amizah
Ab Kadir, Mohd Zainal Abidin
Gomes, Chandima
Jasni, Jasronita
Izadi, Mahdi
On the bending effects of a copper-type down conductor
title On the bending effects of a copper-type down conductor
title_full On the bending effects of a copper-type down conductor
title_fullStr On the bending effects of a copper-type down conductor
title_full_unstemmed On the bending effects of a copper-type down conductor
title_short On the bending effects of a copper-type down conductor
title_sort on the bending effects of a copper type down conductor
url http://psasir.upm.edu.my/id/eprint/48166/1/On%20the%20bending%20effects%20of%20a%20copper-type%20down%20conductor.pdf
work_keys_str_mv AT mohdariffenamizah onthebendingeffectsofacoppertypedownconductor
AT abkadirmohdzainalabidin onthebendingeffectsofacoppertypedownconductor
AT gomeschandima onthebendingeffectsofacoppertypedownconductor
AT jasnijasronita onthebendingeffectsofacoppertypedownconductor
AT izadimahdi onthebendingeffectsofacoppertypedownconductor