On the bending effects of a copper-type down conductor
Down-conductor is part of critical component in the external Lightning Protection System (LPS) as to divert the lightning current from the air termination to the earth termination system of protected structure. In this paper, numerical analysis approach incorporating the effect of copper conductor b...
Main Authors: | , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IEEE
2014
|
Online Access: | http://psasir.upm.edu.my/id/eprint/48166/1/On%20the%20bending%20effects%20of%20a%20copper-type%20down%20conductor.pdf |
_version_ | 1825929950355521536 |
---|---|
author | Mohd Ariffen, Amizah Ab Kadir, Mohd Zainal Abidin Gomes, Chandima Jasni, Jasronita Izadi, Mahdi |
author_facet | Mohd Ariffen, Amizah Ab Kadir, Mohd Zainal Abidin Gomes, Chandima Jasni, Jasronita Izadi, Mahdi |
author_sort | Mohd Ariffen, Amizah |
collection | UPM |
description | Down-conductor is part of critical component in the external Lightning Protection System (LPS) as to divert the lightning current from the air termination to the earth termination system of protected structure. In this paper, numerical analysis approach incorporating the effect of copper conductor bending angle under current transient and voltage is utilized. Various angles of copper conductor will be synthesized following a simplified and generic, but meticulous, model based on the manufacturer's datasheet specification which is normally used. The fields were analyzed and the results were discussed in comparison with the MS IEC 62305-3 standard accordingly. In this case, the cross-sectional area of down-conductor was selected based on the accessible type produced by various manufacturers as proposed by the MS IEC 62305-3 standard for a critical study. This study presents the optimum angle of down-conductor with a view to develop a practical approach and to set the down-conductors in a confined area locations of a building. |
first_indexed | 2024-03-06T09:04:14Z |
format | Conference or Workshop Item |
id | upm.eprints-48166 |
institution | Universiti Putra Malaysia |
language | English |
last_indexed | 2024-03-06T09:04:14Z |
publishDate | 2014 |
publisher | IEEE |
record_format | dspace |
spelling | upm.eprints-481662016-08-03T08:08:53Z http://psasir.upm.edu.my/id/eprint/48166/ On the bending effects of a copper-type down conductor Mohd Ariffen, Amizah Ab Kadir, Mohd Zainal Abidin Gomes, Chandima Jasni, Jasronita Izadi, Mahdi Down-conductor is part of critical component in the external Lightning Protection System (LPS) as to divert the lightning current from the air termination to the earth termination system of protected structure. In this paper, numerical analysis approach incorporating the effect of copper conductor bending angle under current transient and voltage is utilized. Various angles of copper conductor will be synthesized following a simplified and generic, but meticulous, model based on the manufacturer's datasheet specification which is normally used. The fields were analyzed and the results were discussed in comparison with the MS IEC 62305-3 standard accordingly. In this case, the cross-sectional area of down-conductor was selected based on the accessible type produced by various manufacturers as proposed by the MS IEC 62305-3 standard for a critical study. This study presents the optimum angle of down-conductor with a view to develop a practical approach and to set the down-conductors in a confined area locations of a building. IEEE 2014 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/48166/1/On%20the%20bending%20effects%20of%20a%20copper-type%20down%20conductor.pdf Mohd Ariffen, Amizah and Ab Kadir, Mohd Zainal Abidin and Gomes, Chandima and Jasni, Jasronita and Izadi, Mahdi (2014) On the bending effects of a copper-type down conductor. In: 2014 International Conference on Lightning Protection (ICLP), 11-18 Oct. 2014, Shanghai, China. (pp. 927-935). 10.1109/ICLP.2014.6973256 |
spellingShingle | Mohd Ariffen, Amizah Ab Kadir, Mohd Zainal Abidin Gomes, Chandima Jasni, Jasronita Izadi, Mahdi On the bending effects of a copper-type down conductor |
title | On the bending effects of a copper-type down conductor |
title_full | On the bending effects of a copper-type down conductor |
title_fullStr | On the bending effects of a copper-type down conductor |
title_full_unstemmed | On the bending effects of a copper-type down conductor |
title_short | On the bending effects of a copper-type down conductor |
title_sort | on the bending effects of a copper type down conductor |
url | http://psasir.upm.edu.my/id/eprint/48166/1/On%20the%20bending%20effects%20of%20a%20copper-type%20down%20conductor.pdf |
work_keys_str_mv | AT mohdariffenamizah onthebendingeffectsofacoppertypedownconductor AT abkadirmohdzainalabidin onthebendingeffectsofacoppertypedownconductor AT gomeschandima onthebendingeffectsofacoppertypedownconductor AT jasnijasronita onthebendingeffectsofacoppertypedownconductor AT izadimahdi onthebendingeffectsofacoppertypedownconductor |