Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite

An investigation was carried out to study the effect of the porosity on thermal diffusivity of Nickel Copper Zinc Ferrite. The experimental technique employed to measure thermal diffusivity was the photoflash technique, and the measurements were carried out at room temperature. The heating source co...

ver descrição completa

Detalhes bibliográficos
Principais autores: Grozescu, Ionel Valeriu, Abd. Moksin, Mohd Maarof, Haydari, Mehdi, Yahaya, N., Mat Yunus, Wan Mahmood
Formato: Conference or Workshop Item
Idioma:English
Publicado em: IEEE 2003
Acesso em linha:http://psasir.upm.edu.my/id/eprint/48308/1/Application%20of%20the%20pyroelectric%20sensor%20for%20study%20of%20porosity%20effect%20on%20thermal%20diffusivity%20of%20nickel%20copper%20zink%20ferrite.pdf
_version_ 1825929978866302976
author Grozescu, Ionel Valeriu
Abd. Moksin, Mohd Maarof
Haydari, Mehdi
Yahaya, N.
Mat Yunus, Wan Mahmood
author_facet Grozescu, Ionel Valeriu
Abd. Moksin, Mohd Maarof
Haydari, Mehdi
Yahaya, N.
Mat Yunus, Wan Mahmood
author_sort Grozescu, Ionel Valeriu
collection UPM
description An investigation was carried out to study the effect of the porosity on thermal diffusivity of Nickel Copper Zinc Ferrite. The experimental technique employed to measure thermal diffusivity was the photoflash technique, and the measurements were carried out at room temperature. The heating source consists of camera flash having approximately 5ms pulse duration and a thin film of polyvinylidene difluoride (PVDF) attached to the back of the samples was used as detector. Six different porosity levels were obtained by varying the grinding time following the presintering process and preceding the sintering process at 1350°C. The porosity range obtained for the Ni0.3Cu0.1Zn0.6Fe2O4 samples was 1.8-7%. The thermal diffusivity was determined from the experimental thermal transient signal. For the fitting of the experimental results, the analytical model used was based on the approximation that the pulse duration of the camera flash can be considered as Dirac-δ function. Thermal diffusivity values for Ni0.3Cu0.1Zn0.6Fe2O4 samples were in the range (7.8-8.7) × 10-7 m2/s.
first_indexed 2024-03-06T09:04:39Z
format Conference or Workshop Item
id upm.eprints-48308
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T09:04:39Z
publishDate 2003
publisher IEEE
record_format dspace
spelling upm.eprints-483082016-09-22T08:43:11Z http://psasir.upm.edu.my/id/eprint/48308/ Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite Grozescu, Ionel Valeriu Abd. Moksin, Mohd Maarof Haydari, Mehdi Yahaya, N. Mat Yunus, Wan Mahmood An investigation was carried out to study the effect of the porosity on thermal diffusivity of Nickel Copper Zinc Ferrite. The experimental technique employed to measure thermal diffusivity was the photoflash technique, and the measurements were carried out at room temperature. The heating source consists of camera flash having approximately 5ms pulse duration and a thin film of polyvinylidene difluoride (PVDF) attached to the back of the samples was used as detector. Six different porosity levels were obtained by varying the grinding time following the presintering process and preceding the sintering process at 1350°C. The porosity range obtained for the Ni0.3Cu0.1Zn0.6Fe2O4 samples was 1.8-7%. The thermal diffusivity was determined from the experimental thermal transient signal. For the fitting of the experimental results, the analytical model used was based on the approximation that the pulse duration of the camera flash can be considered as Dirac-δ function. Thermal diffusivity values for Ni0.3Cu0.1Zn0.6Fe2O4 samples were in the range (7.8-8.7) × 10-7 m2/s. IEEE 2003 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/48308/1/Application%20of%20the%20pyroelectric%20sensor%20for%20study%20of%20porosity%20effect%20on%20thermal%20diffusivity%20of%20nickel%20copper%20zink%20ferrite.pdf Grozescu, Ionel Valeriu and Abd. Moksin, Mohd Maarof and Haydari, Mehdi and Yahaya, N. and Mat Yunus, Wan Mahmood (2003) Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite. In: 2003 Asian Conference on Sensors (AsiaSENSE 2003), Malaysia. (pp. 65-68). 10.1109/ASENSE.2003.1224994
spellingShingle Grozescu, Ionel Valeriu
Abd. Moksin, Mohd Maarof
Haydari, Mehdi
Yahaya, N.
Mat Yunus, Wan Mahmood
Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
title Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
title_full Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
title_fullStr Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
title_full_unstemmed Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
title_short Application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
title_sort application of the pyroelectric sensor for study of porosity effect on thermal diffusivity of nickel copper zink ferrite
url http://psasir.upm.edu.my/id/eprint/48308/1/Application%20of%20the%20pyroelectric%20sensor%20for%20study%20of%20porosity%20effect%20on%20thermal%20diffusivity%20of%20nickel%20copper%20zink%20ferrite.pdf
work_keys_str_mv AT grozescuionelvaleriu applicationofthepyroelectricsensorforstudyofporosityeffectonthermaldiffusivityofnickelcopperzinkferrite
AT abdmoksinmohdmaarof applicationofthepyroelectricsensorforstudyofporosityeffectonthermaldiffusivityofnickelcopperzinkferrite
AT haydarimehdi applicationofthepyroelectricsensorforstudyofporosityeffectonthermaldiffusivityofnickelcopperzinkferrite
AT yahayan applicationofthepyroelectricsensorforstudyofporosityeffectonthermaldiffusivityofnickelcopperzinkferrite
AT matyunuswanmahmood applicationofthepyroelectricsensorforstudyofporosityeffectonthermaldiffusivityofnickelcopperzinkferrite