Corrosion characterisation of Al-Cu reinforced in-situ TiB2

Aluminium (Al) based in-situ metal matrix composites (MMCs) have better properties and performance compared to ex-situ MMCs. In this research, aluminium-copper (Al-Cu) alloy was reinforced with 3 and 6wt.% titanium diboride (TiB2). Al-MMCs has been fabricated with salt route reaction process at 800...

Full description

Bibliographic Details
Main Authors: Ramli, Rosmamuhamadani, Sulaiman, Shamsuddin, Mohamed Ariff, Azmah Hanim, Ismail, Mohd Idris Shah, Talari, Mahesh Kumar, Md Yahaya, Sabrina
Format: Conference or Workshop Item
Language:English
Published: EDP Sciences 2016
Online Access:http://psasir.upm.edu.my/id/eprint/50093/1/matecconf_icongdm2016_01001.pdf
_version_ 1796975261888020480
author Ramli, Rosmamuhamadani
Sulaiman, Shamsuddin
Mohamed Ariff, Azmah Hanim
Ismail, Mohd Idris Shah
Talari, Mahesh Kumar
Md Yahaya, Sabrina
author_facet Ramli, Rosmamuhamadani
Sulaiman, Shamsuddin
Mohamed Ariff, Azmah Hanim
Ismail, Mohd Idris Shah
Talari, Mahesh Kumar
Md Yahaya, Sabrina
author_sort Ramli, Rosmamuhamadani
collection UPM
description Aluminium (Al) based in-situ metal matrix composites (MMCs) have better properties and performance compared to ex-situ MMCs. In this research, aluminium-copper (Al-Cu) alloy was reinforced with 3 and 6wt.% titanium diboride (TiB2). Al-MMCs has been fabricated with salt route reaction process at 800 °C via potassium hexafluorotitanate (K2TiF6) and potassium tetrafluoroborate (KBF4) salts. Hardness vickers tester and Gamry-Electrod Potentiometer were used to characterize the hardness properties and to determine the corrosion rate of Al-Cu alloys. From results obtained, increased TiB2 contents will increase the hardness of Al-Cu alloys. Increased of TiB2 contents also will increase the corrosion rate of Al-Cu alloys. Al-Cu with 3wt.%TiB2 gave the good properties of corrosion when the wear rate recorded the lowest value compare to Al-Cu alloy itself and 6 wt.% TiB2. The corrosion rate of Al-Cu with 3wt.TiB2 was 16.15, while Al-Cu and Al-Cu-6wt%TiB2 were 22.5 and 58.7 mm/y respectively.
first_indexed 2024-03-06T09:08:57Z
format Conference or Workshop Item
id upm.eprints-50093
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T09:08:57Z
publishDate 2016
publisher EDP Sciences
record_format dspace
spelling upm.eprints-500932017-02-01T04:47:45Z http://psasir.upm.edu.my/id/eprint/50093/ Corrosion characterisation of Al-Cu reinforced in-situ TiB2 Ramli, Rosmamuhamadani Sulaiman, Shamsuddin Mohamed Ariff, Azmah Hanim Ismail, Mohd Idris Shah Talari, Mahesh Kumar Md Yahaya, Sabrina Aluminium (Al) based in-situ metal matrix composites (MMCs) have better properties and performance compared to ex-situ MMCs. In this research, aluminium-copper (Al-Cu) alloy was reinforced with 3 and 6wt.% titanium diboride (TiB2). Al-MMCs has been fabricated with salt route reaction process at 800 °C via potassium hexafluorotitanate (K2TiF6) and potassium tetrafluoroborate (KBF4) salts. Hardness vickers tester and Gamry-Electrod Potentiometer were used to characterize the hardness properties and to determine the corrosion rate of Al-Cu alloys. From results obtained, increased TiB2 contents will increase the hardness of Al-Cu alloys. Increased of TiB2 contents also will increase the corrosion rate of Al-Cu alloys. Al-Cu with 3wt.%TiB2 gave the good properties of corrosion when the wear rate recorded the lowest value compare to Al-Cu alloy itself and 6 wt.% TiB2. The corrosion rate of Al-Cu with 3wt.TiB2 was 16.15, while Al-Cu and Al-Cu-6wt%TiB2 were 22.5 and 58.7 mm/y respectively. EDP Sciences 2016 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/50093/1/matecconf_icongdm2016_01001.pdf Ramli, Rosmamuhamadani and Sulaiman, Shamsuddin and Mohamed Ariff, Azmah Hanim and Ismail, Mohd Idris Shah and Talari, Mahesh Kumar and Md Yahaya, Sabrina (2016) Corrosion characterisation of Al-Cu reinforced in-situ TiB2. In: 2nd International Conference on Green Design and Manufacture 2016 (IConGDM 2016), 1-2 May 2016, Phuket, Thailand. (pp. 1-7). http://www.matec-conferences.org/articles/matecconf/abs/2016/41/matecconf_icongdm2016_01001/matecconf_icongdm2016_01001.html 10.1051/matecconf/20167801001
spellingShingle Ramli, Rosmamuhamadani
Sulaiman, Shamsuddin
Mohamed Ariff, Azmah Hanim
Ismail, Mohd Idris Shah
Talari, Mahesh Kumar
Md Yahaya, Sabrina
Corrosion characterisation of Al-Cu reinforced in-situ TiB2
title Corrosion characterisation of Al-Cu reinforced in-situ TiB2
title_full Corrosion characterisation of Al-Cu reinforced in-situ TiB2
title_fullStr Corrosion characterisation of Al-Cu reinforced in-situ TiB2
title_full_unstemmed Corrosion characterisation of Al-Cu reinforced in-situ TiB2
title_short Corrosion characterisation of Al-Cu reinforced in-situ TiB2
title_sort corrosion characterisation of al cu reinforced in situ tib2
url http://psasir.upm.edu.my/id/eprint/50093/1/matecconf_icongdm2016_01001.pdf
work_keys_str_mv AT ramlirosmamuhamadani corrosioncharacterisationofalcureinforcedinsitutib2
AT sulaimanshamsuddin corrosioncharacterisationofalcureinforcedinsitutib2
AT mohamedariffazmahhanim corrosioncharacterisationofalcureinforcedinsitutib2
AT ismailmohdidrisshah corrosioncharacterisationofalcureinforcedinsitutib2
AT talarimaheshkumar corrosioncharacterisationofalcureinforcedinsitutib2
AT mdyahayasabrina corrosioncharacterisationofalcureinforcedinsitutib2