Ultrasonication effects on ultrafiltration membrane cleaning and fouling mitigation
Mitigation of fouling on hollow fiber ultrafiltration membrane using ultrasonication has been carried out. The effects of different contact times, at constant frequency and power of 28 kHz and 60 Watt, respectively on membrane cleaning with and without chemical agents were studied. Results showed th...
Main Authors: | Mohamad Idris, Aida Isma, Omar, Rozita, Idris, Azni |
---|---|
Format: | Article |
Language: | English |
Published: |
2016
|
Online Access: | http://psasir.upm.edu.my/id/eprint/53182/1/Ultrasonication%20effects%20on%20ultrafiltration%20membrane%20cleaning%20and%20fouling%20mitigation.pdf |
Similar Items
-
Cleaning potential of surfaction of fouled ultrafiltration (UF) membranes
by: Mohd Hafez Mohd Isa,, et al.
Published: (2012) -
In-situ biofouling mitigation using ultrasonication in membrane bioreactor
by: Mohamad Idris, Aida Isma
Published: (2016) -
Effects of SRT and HRT on treatment performance of MBR and membrane fouling
by: Mohd Idris, Aida Isma, et al.
Published: (2014) -
Characterization of bio fouling in membrane bioreactor
by: M. I., Aida Isma, et al.
Published: (2016) -
Fouling characteristics and cleaning approach of ultrafiltration membrane during xylose reductase separation
by: Krishnan, Santhana, et al.
Published: (2022)