Procedures for evaluating the HV overhead lines lightning performance and methods for reducing the OHL trip rate in TNB transmission

In this paper, the procedures for evaluating the High Voltage (132kV, 275kV and 500kV) overhead lines performance due to lightning in TNB transmission is discussed. The historical tripping data is analysed and compared from the international standard IEC 60071-1 and other utility practices. Approach...

Full description

Bibliographic Details
Main Authors: Mohamed Rawi, Iryani, Ab Kadir, Mohd Zainal Abidin
Format: Conference or Workshop Item
Language:English
Published: IEEE 2014
Online Access:http://psasir.upm.edu.my/id/eprint/55930/1/Procedures%20for%20evaluating%20the%20HV%20overhead%20lines%20lightning%20performance%20and%20methods%20for%20reducing%20the%20OHL%20trip%20rate%20in%20TNB%20transmission.pdf
_version_ 1825931315724156928
author Mohamed Rawi, Iryani
Ab Kadir, Mohd Zainal Abidin
author_facet Mohamed Rawi, Iryani
Ab Kadir, Mohd Zainal Abidin
author_sort Mohamed Rawi, Iryani
collection UPM
description In this paper, the procedures for evaluating the High Voltage (132kV, 275kV and 500kV) overhead lines performance due to lightning in TNB transmission is discussed. The historical tripping data is analysed and compared from the international standard IEC 60071-1 and other utility practices. Approaches for evaluating the performance i.e. software simulations using TFlash and SIGMA SLP are part of the study. Lightning stroke data will also be shown, which will be compared with the tripping pattern. The condition of the transmission towers and Tower Footing Resistance are also very essential in determining the line performance. As conclusion, this paper will discuss and propose the method and actions for reducing OHL tripping due to lightning, thus improving the line performance.
first_indexed 2024-03-06T09:24:53Z
format Conference or Workshop Item
id upm.eprints-55930
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T09:24:53Z
publishDate 2014
publisher IEEE
record_format dspace
spelling upm.eprints-559302019-11-20T02:40:55Z http://psasir.upm.edu.my/id/eprint/55930/ Procedures for evaluating the HV overhead lines lightning performance and methods for reducing the OHL trip rate in TNB transmission Mohamed Rawi, Iryani Ab Kadir, Mohd Zainal Abidin In this paper, the procedures for evaluating the High Voltage (132kV, 275kV and 500kV) overhead lines performance due to lightning in TNB transmission is discussed. The historical tripping data is analysed and compared from the international standard IEC 60071-1 and other utility practices. Approaches for evaluating the performance i.e. software simulations using TFlash and SIGMA SLP are part of the study. Lightning stroke data will also be shown, which will be compared with the tripping pattern. The condition of the transmission towers and Tower Footing Resistance are also very essential in determining the line performance. As conclusion, this paper will discuss and propose the method and actions for reducing OHL tripping due to lightning, thus improving the line performance. IEEE 2014 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/55930/1/Procedures%20for%20evaluating%20the%20HV%20overhead%20lines%20lightning%20performance%20and%20methods%20for%20reducing%20the%20OHL%20trip%20rate%20in%20TNB%20transmission.pdf Mohamed Rawi, Iryani and Ab Kadir, Mohd Zainal Abidin (2014) Procedures for evaluating the HV overhead lines lightning performance and methods for reducing the OHL trip rate in TNB transmission. In: 2014 IEEE 8th International Power Engineering and Optimization Conference (PEOCO2014), 24-25 Mar. 2014, Langkawi, Kedah, Malaysia. (pp. 375-379). 10.1109/PEOCO.2014.6814457
spellingShingle Mohamed Rawi, Iryani
Ab Kadir, Mohd Zainal Abidin
Procedures for evaluating the HV overhead lines lightning performance and methods for reducing the OHL trip rate in TNB transmission
title Procedures for evaluating the HV overhead lines lightning performance and methods for reducing the OHL trip rate in TNB transmission
title_full Procedures for evaluating the HV overhead lines lightning performance and methods for reducing the OHL trip rate in TNB transmission
title_fullStr Procedures for evaluating the HV overhead lines lightning performance and methods for reducing the OHL trip rate in TNB transmission
title_full_unstemmed Procedures for evaluating the HV overhead lines lightning performance and methods for reducing the OHL trip rate in TNB transmission
title_short Procedures for evaluating the HV overhead lines lightning performance and methods for reducing the OHL trip rate in TNB transmission
title_sort procedures for evaluating the hv overhead lines lightning performance and methods for reducing the ohl trip rate in tnb transmission
url http://psasir.upm.edu.my/id/eprint/55930/1/Procedures%20for%20evaluating%20the%20HV%20overhead%20lines%20lightning%20performance%20and%20methods%20for%20reducing%20the%20OHL%20trip%20rate%20in%20TNB%20transmission.pdf
work_keys_str_mv AT mohamedrawiiryani proceduresforevaluatingthehvoverheadlineslightningperformanceandmethodsforreducingtheohltriprateintnbtransmission
AT abkadirmohdzainalabidin proceduresforevaluatingthehvoverheadlineslightningperformanceandmethodsforreducingtheohltriprateintnbtransmission