Investigation on the lightning breakdown voltage of palm oil and coconut oil under non-uniform field

The increasing interests on the Palm Oil (PO) and Coconut Oil (CO) as a potential alternative for dielectric insulating fluid in transformers encourage a number of researches on different aspects of these oils. Among the common areas under study is the lightning breakdown voltage. In this paper, the...

Full description

Bibliographic Details
Main Authors: Thien, Yee Von, Azis, Norhafiz, Jasni, Jasronita, Ab Kadir, Mohd Zainal Abidin, Yunus, Robiah, Ishak, Mohd Taufiq, Yaakub, Zaini
Format: Conference or Workshop Item
Language:English
Published: IEEE 2014
Online Access:http://psasir.upm.edu.my/id/eprint/56344/1/Investigation%20on%20the%20lightning%20breakdown%20voltage%20of%20palm%20oil%20and%20coconut%20oil%20under%20non-uniform%20field.pdf
_version_ 1825931397523570688
author Thien, Yee Von
Azis, Norhafiz
Jasni, Jasronita
Ab Kadir, Mohd Zainal Abidin
Yunus, Robiah
Ishak, Mohd Taufiq
Yaakub, Zaini
author_facet Thien, Yee Von
Azis, Norhafiz
Jasni, Jasronita
Ab Kadir, Mohd Zainal Abidin
Yunus, Robiah
Ishak, Mohd Taufiq
Yaakub, Zaini
author_sort Thien, Yee Von
collection UPM
description The increasing interests on the Palm Oil (PO) and Coconut Oil (CO) as a potential alternative for dielectric insulating fluid in transformers encourage a number of researches on different aspects of these oils. Among the common areas under study is the lightning breakdown voltage. In this paper, the lightning breakdown voltage of PO and CO is examined. The type of PO used in this study is Refined, Bleached and Deodorized Palm Oil (RBDPO) Olein. The testing was carried out under non-uniform electric field using needle-sphere electrodes configuration. The influence of the testing methods, rising-voltage and up-and-down on the breakdown voltages are investigated for both types of oils. It was found that the lightning breakdown voltage performance for some of the RBDPO is comparable to Mineral Oil (MO).
first_indexed 2024-03-06T09:26:07Z
format Conference or Workshop Item
id upm.eprints-56344
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T09:26:07Z
publishDate 2014
publisher IEEE
record_format dspace
spelling upm.eprints-563442017-07-31T09:08:01Z http://psasir.upm.edu.my/id/eprint/56344/ Investigation on the lightning breakdown voltage of palm oil and coconut oil under non-uniform field Thien, Yee Von Azis, Norhafiz Jasni, Jasronita Ab Kadir, Mohd Zainal Abidin Yunus, Robiah Ishak, Mohd Taufiq Yaakub, Zaini The increasing interests on the Palm Oil (PO) and Coconut Oil (CO) as a potential alternative for dielectric insulating fluid in transformers encourage a number of researches on different aspects of these oils. Among the common areas under study is the lightning breakdown voltage. In this paper, the lightning breakdown voltage of PO and CO is examined. The type of PO used in this study is Refined, Bleached and Deodorized Palm Oil (RBDPO) Olein. The testing was carried out under non-uniform electric field using needle-sphere electrodes configuration. The influence of the testing methods, rising-voltage and up-and-down on the breakdown voltages are investigated for both types of oils. It was found that the lightning breakdown voltage performance for some of the RBDPO is comparable to Mineral Oil (MO). IEEE 2014 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/56344/1/Investigation%20on%20the%20lightning%20breakdown%20voltage%20of%20palm%20oil%20and%20coconut%20oil%20under%20non-uniform%20field.pdf Thien, Yee Von and Azis, Norhafiz and Jasni, Jasronita and Ab Kadir, Mohd Zainal Abidin and Yunus, Robiah and Ishak, Mohd Taufiq and Yaakub, Zaini (2014) Investigation on the lightning breakdown voltage of palm oil and coconut oil under non-uniform field. In: 2014 IEEE International Conference on Power and Energy (PECon 2014), 1-3 Dec. 2014, Kuching, Sarawak, Malaysia. (pp. 1-4). 10.1109/PECON.2014.7062402
spellingShingle Thien, Yee Von
Azis, Norhafiz
Jasni, Jasronita
Ab Kadir, Mohd Zainal Abidin
Yunus, Robiah
Ishak, Mohd Taufiq
Yaakub, Zaini
Investigation on the lightning breakdown voltage of palm oil and coconut oil under non-uniform field
title Investigation on the lightning breakdown voltage of palm oil and coconut oil under non-uniform field
title_full Investigation on the lightning breakdown voltage of palm oil and coconut oil under non-uniform field
title_fullStr Investigation on the lightning breakdown voltage of palm oil and coconut oil under non-uniform field
title_full_unstemmed Investigation on the lightning breakdown voltage of palm oil and coconut oil under non-uniform field
title_short Investigation on the lightning breakdown voltage of palm oil and coconut oil under non-uniform field
title_sort investigation on the lightning breakdown voltage of palm oil and coconut oil under non uniform field
url http://psasir.upm.edu.my/id/eprint/56344/1/Investigation%20on%20the%20lightning%20breakdown%20voltage%20of%20palm%20oil%20and%20coconut%20oil%20under%20non-uniform%20field.pdf
work_keys_str_mv AT thienyeevon investigationonthelightningbreakdownvoltageofpalmoilandcoconutoilundernonuniformfield
AT azisnorhafiz investigationonthelightningbreakdownvoltageofpalmoilandcoconutoilundernonuniformfield
AT jasnijasronita investigationonthelightningbreakdownvoltageofpalmoilandcoconutoilundernonuniformfield
AT abkadirmohdzainalabidin investigationonthelightningbreakdownvoltageofpalmoilandcoconutoilundernonuniformfield
AT yunusrobiah investigationonthelightningbreakdownvoltageofpalmoilandcoconutoilundernonuniformfield
AT ishakmohdtaufiq investigationonthelightningbreakdownvoltageofpalmoilandcoconutoilundernonuniformfield
AT yaakubzaini investigationonthelightningbreakdownvoltageofpalmoilandcoconutoilundernonuniformfield