Simulation and Optimization of Thermosyphon Solar WateHeater for Kuala Lumpur Climate Using Trnsys Software

Solar energy can be utilized for hot water supply in Malaysia but demand is at night and in the early morning. Auxiliary heater can help reduce this mismatch. The objective of this project is to develop a transient simulation program (TRNSYS) by set the system using suitable parameters for Kuala...

Full description

Bibliographic Details
Main Author: Zahedi, Seyed Hamidreza
Format: Thesis
Language:English
English
Published: 2005
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/6060/1/FK_2005_48.pdf
_version_ 1796967088619782144
author Zahedi, Seyed Hamidreza
author_facet Zahedi, Seyed Hamidreza
author_sort Zahedi, Seyed Hamidreza
collection UPM
description Solar energy can be utilized for hot water supply in Malaysia but demand is at night and in the early morning. Auxiliary heater can help reduce this mismatch. The objective of this project is to develop a transient simulation program (TRNSYS) by set the system using suitable parameters for Kuala Lumpur, to determine the optimal system design and the system performance during the year for 150literfday hot water consumption for five persons. TRNSYS is a transient system simulation program which is use for thermal analysis of a variety of time dependent systems. The modular nature of TRNSYS permits simulation of a great variety of particular components of a physical system and facilitates the add ons to the program of mathematical model which is not included in standard TRNSYS library. A typical thermosyphon solar domestic hot water (DHW) system can be modeled by connecting thermosyphon collector storage subsystem (Type 49, Typical Meteorological Year (TMY) weather data reader (Type89), radiation processor (Type 16), heating load component (Type 14), integrator (Type 24) and online plotter (Type65). It was observed that the collector should be tilted at @+(7" + 37")which is faced to south, according to Kuala Lumpur latitude (e3.14q.In terms of storage tanks configuration the vertical system has better performance rather than horizontal one. The optimal system designs are: Nr=lO, D, =5 mm, Do, Di=15mm, H, when the Ht is lm2 should be more than 0.8m and the optimum tank height is about lm. In case of tank volume it is highly depend on the set point (hot water temperature to load), but for most of the cases is between 125-150 liter. The optimum collector area for 150 litertday consumption is about 2m2; there is no effect in increasing the collector area. It is concluded that the system without auxiliary water heater can not reach the requirements, if the set point is 55°C. In most of the month of the year the mean monthly water temperature is more than 50°C. The auxiliary is needed for cooler months like June, July and November. The auxiliary heating consumption in solar system is about 90% less than the geyser (see Figure5.19).
first_indexed 2024-03-06T07:08:47Z
format Thesis
id upm.eprints-6060
institution Universiti Putra Malaysia
language English
English
last_indexed 2024-03-06T07:08:47Z
publishDate 2005
record_format dspace
spelling upm.eprints-60602023-01-05T07:46:59Z http://psasir.upm.edu.my/id/eprint/6060/ Simulation and Optimization of Thermosyphon Solar WateHeater for Kuala Lumpur Climate Using Trnsys Software Zahedi, Seyed Hamidreza Solar energy can be utilized for hot water supply in Malaysia but demand is at night and in the early morning. Auxiliary heater can help reduce this mismatch. The objective of this project is to develop a transient simulation program (TRNSYS) by set the system using suitable parameters for Kuala Lumpur, to determine the optimal system design and the system performance during the year for 150literfday hot water consumption for five persons. TRNSYS is a transient system simulation program which is use for thermal analysis of a variety of time dependent systems. The modular nature of TRNSYS permits simulation of a great variety of particular components of a physical system and facilitates the add ons to the program of mathematical model which is not included in standard TRNSYS library. A typical thermosyphon solar domestic hot water (DHW) system can be modeled by connecting thermosyphon collector storage subsystem (Type 49, Typical Meteorological Year (TMY) weather data reader (Type89), radiation processor (Type 16), heating load component (Type 14), integrator (Type 24) and online plotter (Type65). It was observed that the collector should be tilted at @+(7" + 37")which is faced to south, according to Kuala Lumpur latitude (e3.14q.In terms of storage tanks configuration the vertical system has better performance rather than horizontal one. The optimal system designs are: Nr=lO, D, =5 mm, Do, Di=15mm, H, when the Ht is lm2 should be more than 0.8m and the optimum tank height is about lm. In case of tank volume it is highly depend on the set point (hot water temperature to load), but for most of the cases is between 125-150 liter. The optimum collector area for 150 litertday consumption is about 2m2; there is no effect in increasing the collector area. It is concluded that the system without auxiliary water heater can not reach the requirements, if the set point is 55°C. In most of the month of the year the mean monthly water temperature is more than 50°C. The auxiliary is needed for cooler months like June, July and November. The auxiliary heating consumption in solar system is about 90% less than the geyser (see Figure5.19). 2005-04 Thesis NonPeerReviewed text en http://psasir.upm.edu.my/id/eprint/6060/1/FK_2005_48.pdf Zahedi, Seyed Hamidreza (2005) Simulation and Optimization of Thermosyphon Solar WateHeater for Kuala Lumpur Climate Using Trnsys Software. Masters thesis, Universiti Putra Malaysia. Solar water heaters - Case studies Thermosyphons Thermal Analysis - Computer programs English
spellingShingle Solar water heaters - Case studies
Thermosyphons
Thermal Analysis - Computer programs
Zahedi, Seyed Hamidreza
Simulation and Optimization of Thermosyphon Solar WateHeater for Kuala Lumpur Climate Using Trnsys Software
title Simulation and Optimization of Thermosyphon Solar WateHeater for Kuala Lumpur Climate Using Trnsys Software
title_full Simulation and Optimization of Thermosyphon Solar WateHeater for Kuala Lumpur Climate Using Trnsys Software
title_fullStr Simulation and Optimization of Thermosyphon Solar WateHeater for Kuala Lumpur Climate Using Trnsys Software
title_full_unstemmed Simulation and Optimization of Thermosyphon Solar WateHeater for Kuala Lumpur Climate Using Trnsys Software
title_short Simulation and Optimization of Thermosyphon Solar WateHeater for Kuala Lumpur Climate Using Trnsys Software
title_sort simulation and optimization of thermosyphon solar wateheater for kuala lumpur climate using trnsys software
topic Solar water heaters - Case studies
Thermosyphons
Thermal Analysis - Computer programs
url http://psasir.upm.edu.my/id/eprint/6060/1/FK_2005_48.pdf
work_keys_str_mv AT zahediseyedhamidreza simulationandoptimizationofthermosyphonsolarwateheaterforkualalumpurclimateusingtrnsyssoftware