Dosimetry audits and intercomparisons in radiotherapy: a Malaysian profile

Quality audits and intercomparisons are important in ensuring control of processes in any system of endeavour. Present interest is in control of dosimetry in teletherapy, there being a need to assess the extent to which there is consistent radiation dose delivery to the patient. In this study we rev...

Descrición completa

Detalles Bibliográficos
Main Authors: M. Noor, Noramaliza, Nisbet, A., Hussein, M., Saifuddin, Sarene Chu, Kadni, T., Abdullah, N., Bradley, D.A.
Formato: Artigo
Idioma:English
Publicado: Elsevier 2017
Acceso en liña:http://psasir.upm.edu.my/id/eprint/61517/1/Dosimetry%20audits%20and%20intercomparisons%20in%20radiotherapy%20a%20Malaysian%20profile.pdf
_version_ 1825932348952150016
author M. Noor, Noramaliza
Nisbet, A.
Hussein, M.
Saifuddin, Sarene Chu
Kadni, T.
Abdullah, N.
Bradley, D.A.
author_facet M. Noor, Noramaliza
Nisbet, A.
Hussein, M.
Saifuddin, Sarene Chu
Kadni, T.
Abdullah, N.
Bradley, D.A.
author_sort M. Noor, Noramaliza
collection UPM
description Quality audits and intercomparisons are important in ensuring control of processes in any system of endeavour. Present interest is in control of dosimetry in teletherapy, there being a need to assess the extent to which there is consistent radiation dose delivery to the patient. In this study we review significant factors that impact upon radiotherapy dosimetry, focusing upon the example situation of radiotherapy delivery in Malaysia, examining existing literature in support of such efforts. A number of recommendations are made to provide for increased quality assurance and control. In addition to this study, the first level of intercomparison audit i.e. measuring beam output under reference conditions at eight selected Malaysian radiotherapy centres is checked; use being made of 9 µm core diameter Ge-doped silica fibres (Ge-9 µm). The results of Malaysian Secondary Standard Dosimetry Laboratory (SSDL) participation in the IAEA/WHO TLD postal dose audit services during the period between 2011 and 2015 will also been discussed. In conclusion, following review of the development of dosimetry audits and the conduct of one such exercise in Malaysia, it is apparent that regular periodic radiotherapy audits and intercomparison programmes should be strongly supported and implemented worldwide. The programmes to-date demonstrate these to be a good indicator of errors and of consistency between centres. A total of ei+ght beams have been checked in eight Malaysian radiotherapy centres. One out of the eight beams checked produced an unacceptable deviation; this was found to be due to unfamiliarity with the irradiation procedures. Prior to a repeat measurement, the mean ratio of measured to quoted dose was found to be 0.99 with standard deviation of 3%. Subsequent to the repeat measurement, the mean distribution was 1.00, and the standard deviation was 1.3%.
first_indexed 2024-03-06T09:40:39Z
format Article
id upm.eprints-61517
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T09:40:39Z
publishDate 2017
publisher Elsevier
record_format dspace
spelling upm.eprints-615172022-04-04T07:36:46Z http://psasir.upm.edu.my/id/eprint/61517/ Dosimetry audits and intercomparisons in radiotherapy: a Malaysian profile M. Noor, Noramaliza Nisbet, A. Hussein, M. Saifuddin, Sarene Chu Kadni, T. Abdullah, N. Bradley, D.A. Quality audits and intercomparisons are important in ensuring control of processes in any system of endeavour. Present interest is in control of dosimetry in teletherapy, there being a need to assess the extent to which there is consistent radiation dose delivery to the patient. In this study we review significant factors that impact upon radiotherapy dosimetry, focusing upon the example situation of radiotherapy delivery in Malaysia, examining existing literature in support of such efforts. A number of recommendations are made to provide for increased quality assurance and control. In addition to this study, the first level of intercomparison audit i.e. measuring beam output under reference conditions at eight selected Malaysian radiotherapy centres is checked; use being made of 9 µm core diameter Ge-doped silica fibres (Ge-9 µm). The results of Malaysian Secondary Standard Dosimetry Laboratory (SSDL) participation in the IAEA/WHO TLD postal dose audit services during the period between 2011 and 2015 will also been discussed. In conclusion, following review of the development of dosimetry audits and the conduct of one such exercise in Malaysia, it is apparent that regular periodic radiotherapy audits and intercomparison programmes should be strongly supported and implemented worldwide. The programmes to-date demonstrate these to be a good indicator of errors and of consistency between centres. A total of ei+ght beams have been checked in eight Malaysian radiotherapy centres. One out of the eight beams checked produced an unacceptable deviation; this was found to be due to unfamiliarity with the irradiation procedures. Prior to a repeat measurement, the mean ratio of measured to quoted dose was found to be 0.99 with standard deviation of 3%. Subsequent to the repeat measurement, the mean distribution was 1.00, and the standard deviation was 1.3%. Elsevier 2017-11 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/61517/1/Dosimetry%20audits%20and%20intercomparisons%20in%20radiotherapy%20a%20Malaysian%20profile.pdf M. Noor, Noramaliza and Nisbet, A. and Hussein, M. and Saifuddin, Sarene Chu and Kadni, T. and Abdullah, N. and Bradley, D.A. (2017) Dosimetry audits and intercomparisons in radiotherapy: a Malaysian profile. Radiation Physics and Chemistry, 140. 207 - 212. ISSN 0969-806X; ESSN: 1879-0895 https://www.sciencedirect.com/science/article/pii/S0969806X17303730 10.1016/j.radphyschem.2017.03.046
spellingShingle M. Noor, Noramaliza
Nisbet, A.
Hussein, M.
Saifuddin, Sarene Chu
Kadni, T.
Abdullah, N.
Bradley, D.A.
Dosimetry audits and intercomparisons in radiotherapy: a Malaysian profile
title Dosimetry audits and intercomparisons in radiotherapy: a Malaysian profile
title_full Dosimetry audits and intercomparisons in radiotherapy: a Malaysian profile
title_fullStr Dosimetry audits and intercomparisons in radiotherapy: a Malaysian profile
title_full_unstemmed Dosimetry audits and intercomparisons in radiotherapy: a Malaysian profile
title_short Dosimetry audits and intercomparisons in radiotherapy: a Malaysian profile
title_sort dosimetry audits and intercomparisons in radiotherapy a malaysian profile
url http://psasir.upm.edu.my/id/eprint/61517/1/Dosimetry%20audits%20and%20intercomparisons%20in%20radiotherapy%20a%20Malaysian%20profile.pdf
work_keys_str_mv AT mnoornoramaliza dosimetryauditsandintercomparisonsinradiotherapyamalaysianprofile
AT nisbeta dosimetryauditsandintercomparisonsinradiotherapyamalaysianprofile
AT husseinm dosimetryauditsandintercomparisonsinradiotherapyamalaysianprofile
AT saifuddinsarenechu dosimetryauditsandintercomparisonsinradiotherapyamalaysianprofile
AT kadnit dosimetryauditsandintercomparisonsinradiotherapyamalaysianprofile
AT abdullahn dosimetryauditsandintercomparisonsinradiotherapyamalaysianprofile
AT bradleyda dosimetryauditsandintercomparisonsinradiotherapyamalaysianprofile