Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams
This study investigates the reproducibility of commercial optically stimulated luminescence (OSL) system at different X-ray beams in general radiography. The reader stability was evaluated at first and found to be within the accepted tolerance level of ± 10%. Henceforth, reproducibility of OSL dosim...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Akadémiai Kiadó
2017
|
Online Access: | http://psasir.upm.edu.my/id/eprint/62959/1/Reproducibility%20assessment%20of%20commercial%20optically%20stimulated.pdf |
_version_ | 1796977676221677568 |
---|---|
author | Musa, Yahaya Hashim, Suhairul Bradley, David A. Abdul Karim, Muhammad Khalis Hashim, Asmaliza |
author_facet | Musa, Yahaya Hashim, Suhairul Bradley, David A. Abdul Karim, Muhammad Khalis Hashim, Asmaliza |
author_sort | Musa, Yahaya |
collection | UPM |
description | This study investigates the reproducibility of commercial optically stimulated luminescence (OSL) system at different X-ray beams in general radiography. The reader stability was evaluated at first and found to be within the accepted tolerance level of ± 10%. Henceforth, reproducibility of OSL dosimeters due to repeated readouts after single exposure were found to be between 1.0% (80 kV/20 mGy) and 5.9% (80 kV/10 mAs), while reproducibility in repeated irradiation of optically stimulated luminescence dosimeters (OSLDs) from the same batch (80 kV/8 mGy) was between 1.8 and 4.3%. After multiple readouts of OSLD, the OSL signal decreased by approximately − 0.4% per readout and − 5.4% per 10 sequential readouts. The reproducibility response demonstrates the suitability of the nanoDots OSLD for use in radiography. |
first_indexed | 2024-03-06T09:43:35Z |
format | Article |
id | upm.eprints-62959 |
institution | Universiti Putra Malaysia |
language | English |
last_indexed | 2024-03-06T09:43:35Z |
publishDate | 2017 |
publisher | Akadémiai Kiadó |
record_format | dspace |
spelling | upm.eprints-629592018-11-28T09:24:56Z http://psasir.upm.edu.my/id/eprint/62959/ Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams Musa, Yahaya Hashim, Suhairul Bradley, David A. Abdul Karim, Muhammad Khalis Hashim, Asmaliza This study investigates the reproducibility of commercial optically stimulated luminescence (OSL) system at different X-ray beams in general radiography. The reader stability was evaluated at first and found to be within the accepted tolerance level of ± 10%. Henceforth, reproducibility of OSL dosimeters due to repeated readouts after single exposure were found to be between 1.0% (80 kV/20 mGy) and 5.9% (80 kV/10 mAs), while reproducibility in repeated irradiation of optically stimulated luminescence dosimeters (OSLDs) from the same batch (80 kV/8 mGy) was between 1.8 and 4.3%. After multiple readouts of OSLD, the OSL signal decreased by approximately − 0.4% per readout and − 5.4% per 10 sequential readouts. The reproducibility response demonstrates the suitability of the nanoDots OSLD for use in radiography. Akadémiai Kiadó 2017-10-23 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/62959/1/Reproducibility%20assessment%20of%20commercial%20optically%20stimulated.pdf Musa, Yahaya and Hashim, Suhairul and Bradley, David A. and Abdul Karim, Muhammad Khalis and Hashim, Asmaliza (2017) Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams. Journal of Radioanalytical and Nuclear Chemistry, 314 (3). 2029 - 2036. ISSN 0236-5731; ESSN: 1588-2780 https://link.springer.com/content/pdf/10.1007%2Fs10967-017-5571-9.pdf 10.1007/s10967-017-5571-9 |
spellingShingle | Musa, Yahaya Hashim, Suhairul Bradley, David A. Abdul Karim, Muhammad Khalis Hashim, Asmaliza Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams |
title | Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams |
title_full | Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams |
title_fullStr | Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams |
title_full_unstemmed | Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams |
title_short | Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams |
title_sort | reproducibility assessment of commercial optically stimulated luminescence system in diagnostic x ray beams |
url | http://psasir.upm.edu.my/id/eprint/62959/1/Reproducibility%20assessment%20of%20commercial%20optically%20stimulated.pdf |
work_keys_str_mv | AT musayahaya reproducibilityassessmentofcommercialopticallystimulatedluminescencesystemindiagnosticxraybeams AT hashimsuhairul reproducibilityassessmentofcommercialopticallystimulatedluminescencesystemindiagnosticxraybeams AT bradleydavida reproducibilityassessmentofcommercialopticallystimulatedluminescencesystemindiagnosticxraybeams AT abdulkarimmuhammadkhalis reproducibilityassessmentofcommercialopticallystimulatedluminescencesystemindiagnosticxraybeams AT hashimasmaliza reproducibilityassessmentofcommercialopticallystimulatedluminescencesystemindiagnosticxraybeams |