Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams

This study investigates the reproducibility of commercial optically stimulated luminescence (OSL) system at different X-ray beams in general radiography. The reader stability was evaluated at first and found to be within the accepted tolerance level of ± 10%. Henceforth, reproducibility of OSL dosim...

Full description

Bibliographic Details
Main Authors: Musa, Yahaya, Hashim, Suhairul, Bradley, David A., Abdul Karim, Muhammad Khalis, Hashim, Asmaliza
Format: Article
Language:English
Published: Akadémiai Kiadó 2017
Online Access:http://psasir.upm.edu.my/id/eprint/62959/1/Reproducibility%20assessment%20of%20commercial%20optically%20stimulated.pdf
_version_ 1796977676221677568
author Musa, Yahaya
Hashim, Suhairul
Bradley, David A.
Abdul Karim, Muhammad Khalis
Hashim, Asmaliza
author_facet Musa, Yahaya
Hashim, Suhairul
Bradley, David A.
Abdul Karim, Muhammad Khalis
Hashim, Asmaliza
author_sort Musa, Yahaya
collection UPM
description This study investigates the reproducibility of commercial optically stimulated luminescence (OSL) system at different X-ray beams in general radiography. The reader stability was evaluated at first and found to be within the accepted tolerance level of ± 10%. Henceforth, reproducibility of OSL dosimeters due to repeated readouts after single exposure were found to be between 1.0% (80 kV/20 mGy) and 5.9% (80 kV/10 mAs), while reproducibility in repeated irradiation of optically stimulated luminescence dosimeters (OSLDs) from the same batch (80 kV/8 mGy) was between 1.8 and 4.3%. After multiple readouts of OSLD, the OSL signal decreased by approximately − 0.4% per readout and − 5.4% per 10 sequential readouts. The reproducibility response demonstrates the suitability of the nanoDots OSLD for use in radiography.
first_indexed 2024-03-06T09:43:35Z
format Article
id upm.eprints-62959
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T09:43:35Z
publishDate 2017
publisher Akadémiai Kiadó
record_format dspace
spelling upm.eprints-629592018-11-28T09:24:56Z http://psasir.upm.edu.my/id/eprint/62959/ Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams Musa, Yahaya Hashim, Suhairul Bradley, David A. Abdul Karim, Muhammad Khalis Hashim, Asmaliza This study investigates the reproducibility of commercial optically stimulated luminescence (OSL) system at different X-ray beams in general radiography. The reader stability was evaluated at first and found to be within the accepted tolerance level of ± 10%. Henceforth, reproducibility of OSL dosimeters due to repeated readouts after single exposure were found to be between 1.0% (80 kV/20 mGy) and 5.9% (80 kV/10 mAs), while reproducibility in repeated irradiation of optically stimulated luminescence dosimeters (OSLDs) from the same batch (80 kV/8 mGy) was between 1.8 and 4.3%. After multiple readouts of OSLD, the OSL signal decreased by approximately − 0.4% per readout and − 5.4% per 10 sequential readouts. The reproducibility response demonstrates the suitability of the nanoDots OSLD for use in radiography. Akadémiai Kiadó 2017-10-23 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/62959/1/Reproducibility%20assessment%20of%20commercial%20optically%20stimulated.pdf Musa, Yahaya and Hashim, Suhairul and Bradley, David A. and Abdul Karim, Muhammad Khalis and Hashim, Asmaliza (2017) Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams. Journal of Radioanalytical and Nuclear Chemistry, 314 (3). 2029 - 2036. ISSN 0236-5731; ESSN: 1588-2780 https://link.springer.com/content/pdf/10.1007%2Fs10967-017-5571-9.pdf 10.1007/s10967-017-5571-9
spellingShingle Musa, Yahaya
Hashim, Suhairul
Bradley, David A.
Abdul Karim, Muhammad Khalis
Hashim, Asmaliza
Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams
title Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams
title_full Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams
title_fullStr Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams
title_full_unstemmed Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams
title_short Reproducibility assessment of commercial optically stimulated luminescence system in diagnostic X-ray beams
title_sort reproducibility assessment of commercial optically stimulated luminescence system in diagnostic x ray beams
url http://psasir.upm.edu.my/id/eprint/62959/1/Reproducibility%20assessment%20of%20commercial%20optically%20stimulated.pdf
work_keys_str_mv AT musayahaya reproducibilityassessmentofcommercialopticallystimulatedluminescencesystemindiagnosticxraybeams
AT hashimsuhairul reproducibilityassessmentofcommercialopticallystimulatedluminescencesystemindiagnosticxraybeams
AT bradleydavida reproducibilityassessmentofcommercialopticallystimulatedluminescencesystemindiagnosticxraybeams
AT abdulkarimmuhammadkhalis reproducibilityassessmentofcommercialopticallystimulatedluminescencesystemindiagnosticxraybeams
AT hashimasmaliza reproducibilityassessmentofcommercialopticallystimulatedluminescencesystemindiagnosticxraybeams