Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia
This study sought to examine the reliability of two measurements; Calf Circumference (CC) and Mid-half Arm Span (MHAS). A sample of 130 elderly persons aged 60 years and above seen consecutively in the Kuala Lumpur Hospital outpatient clinic during the period of December 2005 to January 2006, upo...
Main Authors: | , , , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Nutrition Society of Malaysia
2008
|
Online Access: | http://psasir.upm.edu.my/id/eprint/6490/1/mjn14n2_art2.pdf |
_version_ | 1825944065071382528 |
---|---|
author | Haniff, Jamaiyah Appannah, Geeta Mohammad Nor, Noor Safiza Wong, N. F. Kee, Chee Cheong Zainuddin, Ahmad Ali Shahar, Suzana Rasat, Rahmah Khor, Geok Lin Abd Talib, Ruzita Chen, Won Sun M., Rajaah Yusoff, Ahmad Faudzi |
author_facet | Haniff, Jamaiyah Appannah, Geeta Mohammad Nor, Noor Safiza Wong, N. F. Kee, Chee Cheong Zainuddin, Ahmad Ali Shahar, Suzana Rasat, Rahmah Khor, Geok Lin Abd Talib, Ruzita Chen, Won Sun M., Rajaah Yusoff, Ahmad Faudzi |
author_sort | Haniff, Jamaiyah |
collection | UPM |
description | This study sought to examine the reliability of two measurements; Calf Circumference
(CC) and Mid-half Arm Span (MHAS). A sample of 130 elderly persons aged 60 years
and above seen consecutively in the Kuala Lumpur Hospital outpatient clinic during
the period of December 2005 to January 2006, upon consent, were recruited to the
study. There was a high degree of reliability for both inter- and intra-examiner (r close
to 1). For inter-examiner, on average the CC measurements taken by the first examiner
were 0.3 cm lower than that of the second examiner. The upper and lower limit of the
differences were +0.4 to –0.9 cm respectively. Inter-examiner MHAS measurements
on average by the first examiner were 0.2 cm lower than that of the second examiner.
The limits were +1.7 to –2.1 cm. By comparison, the inter-examiner CC measurements
were more reliable than the MHAS measurements. For intra-examiner, on average the
CC measurements at Time 1 were consistent with Time 2 (mean difference=0) with
limits of the difference at + 0.5 cm. MHAS measurements at Time 1 were on average
0.1 cm less than at Time 2 with limits at +1.7 and –1.8 cm. The technical error of
measurement (TEM) and coefficient of variation of CC and MHAS for both interexaminer
and intra-examiner measurements were within acceptable limits with the
exception of MHAS TEM. This study suggests that CC and MHAS measured in elderly
persons 60 years and above, using Seca Circumference Tape ® 206, Germany (0.05 cm)
are reliable and can be used in a community survey.
|
first_indexed | 2024-03-06T07:10:04Z |
format | Article |
id | upm.eprints-6490 |
institution | Universiti Putra Malaysia |
language | English English |
last_indexed | 2024-03-06T07:10:04Z |
publishDate | 2008 |
publisher | Nutrition Society of Malaysia |
record_format | dspace |
spelling | upm.eprints-64902013-05-27T07:29:51Z http://psasir.upm.edu.my/id/eprint/6490/ Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia Haniff, Jamaiyah Appannah, Geeta Mohammad Nor, Noor Safiza Wong, N. F. Kee, Chee Cheong Zainuddin, Ahmad Ali Shahar, Suzana Rasat, Rahmah Khor, Geok Lin Abd Talib, Ruzita Chen, Won Sun M., Rajaah Yusoff, Ahmad Faudzi This study sought to examine the reliability of two measurements; Calf Circumference (CC) and Mid-half Arm Span (MHAS). A sample of 130 elderly persons aged 60 years and above seen consecutively in the Kuala Lumpur Hospital outpatient clinic during the period of December 2005 to January 2006, upon consent, were recruited to the study. There was a high degree of reliability for both inter- and intra-examiner (r close to 1). For inter-examiner, on average the CC measurements taken by the first examiner were 0.3 cm lower than that of the second examiner. The upper and lower limit of the differences were +0.4 to –0.9 cm respectively. Inter-examiner MHAS measurements on average by the first examiner were 0.2 cm lower than that of the second examiner. The limits were +1.7 to –2.1 cm. By comparison, the inter-examiner CC measurements were more reliable than the MHAS measurements. For intra-examiner, on average the CC measurements at Time 1 were consistent with Time 2 (mean difference=0) with limits of the difference at + 0.5 cm. MHAS measurements at Time 1 were on average 0.1 cm less than at Time 2 with limits at +1.7 and –1.8 cm. The technical error of measurement (TEM) and coefficient of variation of CC and MHAS for both interexaminer and intra-examiner measurements were within acceptable limits with the exception of MHAS TEM. This study suggests that CC and MHAS measured in elderly persons 60 years and above, using Seca Circumference Tape ® 206, Germany (0.05 cm) are reliable and can be used in a community survey. Nutrition Society of Malaysia 2008-09 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/6490/1/mjn14n2_art2.pdf Haniff, Jamaiyah and Appannah, Geeta and Mohammad Nor, Noor Safiza and Wong, N. F. and Kee, Chee Cheong and Zainuddin, Ahmad Ali and Shahar, Suzana and Rasat, Rahmah and Khor, Geok Lin and Abd Talib, Ruzita and Chen, Won Sun and M., Rajaah and Yusoff, Ahmad Faudzi (2008) Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia. Malaysian Journal of Nutrition, 14 (2). pp. 137-150. ISSN 1394-035X http://nutriweb.org.my/publications/mjn0014_2/mjn14n2_art2.php English |
spellingShingle | Haniff, Jamaiyah Appannah, Geeta Mohammad Nor, Noor Safiza Wong, N. F. Kee, Chee Cheong Zainuddin, Ahmad Ali Shahar, Suzana Rasat, Rahmah Khor, Geok Lin Abd Talib, Ruzita Chen, Won Sun M., Rajaah Yusoff, Ahmad Faudzi Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia |
title | Reliability and Technical Error of Calf Circumference and
Mid-half Arm Span Measurements for Nutritional Status
Assessment of Elderly Persons in Malaysia |
title_full | Reliability and Technical Error of Calf Circumference and
Mid-half Arm Span Measurements for Nutritional Status
Assessment of Elderly Persons in Malaysia |
title_fullStr | Reliability and Technical Error of Calf Circumference and
Mid-half Arm Span Measurements for Nutritional Status
Assessment of Elderly Persons in Malaysia |
title_full_unstemmed | Reliability and Technical Error of Calf Circumference and
Mid-half Arm Span Measurements for Nutritional Status
Assessment of Elderly Persons in Malaysia |
title_short | Reliability and Technical Error of Calf Circumference and
Mid-half Arm Span Measurements for Nutritional Status
Assessment of Elderly Persons in Malaysia |
title_sort | reliability and technical error of calf circumference and mid half arm span measurements for nutritional status assessment of elderly persons in malaysia |
url | http://psasir.upm.edu.my/id/eprint/6490/1/mjn14n2_art2.pdf |
work_keys_str_mv | AT haniffjamaiyah reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia AT appannahgeeta reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia AT mohammadnornoorsafiza reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia AT wongnf reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia AT keecheecheong reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia AT zainuddinahmadali reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia AT shaharsuzana reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia AT rasatrahmah reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia AT khorgeoklin reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia AT abdtalibruzita reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia AT chenwonsun reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia AT mrajaah reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia AT yusoffahmadfaudzi reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia |