Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia

This study sought to examine the reliability of two measurements; Calf Circumference (CC) and Mid-half Arm Span (MHAS). A sample of 130 elderly persons aged 60 years and above seen consecutively in the Kuala Lumpur Hospital outpatient clinic during the period of December 2005 to January 2006, upo...

Full description

Bibliographic Details
Main Authors: Haniff, Jamaiyah, Appannah, Geeta, Mohammad Nor, Noor Safiza, Wong, N. F., Kee, Chee Cheong, Zainuddin, Ahmad Ali, Shahar, Suzana, Rasat, Rahmah, Khor, Geok Lin, Abd Talib, Ruzita, Chen, Won Sun, M., Rajaah, Yusoff, Ahmad Faudzi
Format: Article
Language:English
English
Published: Nutrition Society of Malaysia 2008
Online Access:http://psasir.upm.edu.my/id/eprint/6490/1/mjn14n2_art2.pdf
_version_ 1825944065071382528
author Haniff, Jamaiyah
Appannah, Geeta
Mohammad Nor, Noor Safiza
Wong, N. F.
Kee, Chee Cheong
Zainuddin, Ahmad Ali
Shahar, Suzana
Rasat, Rahmah
Khor, Geok Lin
Abd Talib, Ruzita
Chen, Won Sun
M., Rajaah
Yusoff, Ahmad Faudzi
author_facet Haniff, Jamaiyah
Appannah, Geeta
Mohammad Nor, Noor Safiza
Wong, N. F.
Kee, Chee Cheong
Zainuddin, Ahmad Ali
Shahar, Suzana
Rasat, Rahmah
Khor, Geok Lin
Abd Talib, Ruzita
Chen, Won Sun
M., Rajaah
Yusoff, Ahmad Faudzi
author_sort Haniff, Jamaiyah
collection UPM
description This study sought to examine the reliability of two measurements; Calf Circumference (CC) and Mid-half Arm Span (MHAS). A sample of 130 elderly persons aged 60 years and above seen consecutively in the Kuala Lumpur Hospital outpatient clinic during the period of December 2005 to January 2006, upon consent, were recruited to the study. There was a high degree of reliability for both inter- and intra-examiner (r close to 1). For inter-examiner, on average the CC measurements taken by the first examiner were 0.3 cm lower than that of the second examiner. The upper and lower limit of the differences were +0.4 to –0.9 cm respectively. Inter-examiner MHAS measurements on average by the first examiner were 0.2 cm lower than that of the second examiner. The limits were +1.7 to –2.1 cm. By comparison, the inter-examiner CC measurements were more reliable than the MHAS measurements. For intra-examiner, on average the CC measurements at Time 1 were consistent with Time 2 (mean difference=0) with limits of the difference at + 0.5 cm. MHAS measurements at Time 1 were on average 0.1 cm less than at Time 2 with limits at +1.7 and –1.8 cm. The technical error of measurement (TEM) and coefficient of variation of CC and MHAS for both interexaminer and intra-examiner measurements were within acceptable limits with the exception of MHAS TEM. This study suggests that CC and MHAS measured in elderly persons 60 years and above, using Seca Circumference Tape ® 206, Germany (0.05 cm) are reliable and can be used in a community survey.
first_indexed 2024-03-06T07:10:04Z
format Article
id upm.eprints-6490
institution Universiti Putra Malaysia
language English
English
last_indexed 2024-03-06T07:10:04Z
publishDate 2008
publisher Nutrition Society of Malaysia
record_format dspace
spelling upm.eprints-64902013-05-27T07:29:51Z http://psasir.upm.edu.my/id/eprint/6490/ Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia Haniff, Jamaiyah Appannah, Geeta Mohammad Nor, Noor Safiza Wong, N. F. Kee, Chee Cheong Zainuddin, Ahmad Ali Shahar, Suzana Rasat, Rahmah Khor, Geok Lin Abd Talib, Ruzita Chen, Won Sun M., Rajaah Yusoff, Ahmad Faudzi This study sought to examine the reliability of two measurements; Calf Circumference (CC) and Mid-half Arm Span (MHAS). A sample of 130 elderly persons aged 60 years and above seen consecutively in the Kuala Lumpur Hospital outpatient clinic during the period of December 2005 to January 2006, upon consent, were recruited to the study. There was a high degree of reliability for both inter- and intra-examiner (r close to 1). For inter-examiner, on average the CC measurements taken by the first examiner were 0.3 cm lower than that of the second examiner. The upper and lower limit of the differences were +0.4 to –0.9 cm respectively. Inter-examiner MHAS measurements on average by the first examiner were 0.2 cm lower than that of the second examiner. The limits were +1.7 to –2.1 cm. By comparison, the inter-examiner CC measurements were more reliable than the MHAS measurements. For intra-examiner, on average the CC measurements at Time 1 were consistent with Time 2 (mean difference=0) with limits of the difference at + 0.5 cm. MHAS measurements at Time 1 were on average 0.1 cm less than at Time 2 with limits at +1.7 and –1.8 cm. The technical error of measurement (TEM) and coefficient of variation of CC and MHAS for both interexaminer and intra-examiner measurements were within acceptable limits with the exception of MHAS TEM. This study suggests that CC and MHAS measured in elderly persons 60 years and above, using Seca Circumference Tape ® 206, Germany (0.05 cm) are reliable and can be used in a community survey. Nutrition Society of Malaysia 2008-09 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/6490/1/mjn14n2_art2.pdf Haniff, Jamaiyah and Appannah, Geeta and Mohammad Nor, Noor Safiza and Wong, N. F. and Kee, Chee Cheong and Zainuddin, Ahmad Ali and Shahar, Suzana and Rasat, Rahmah and Khor, Geok Lin and Abd Talib, Ruzita and Chen, Won Sun and M., Rajaah and Yusoff, Ahmad Faudzi (2008) Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia. Malaysian Journal of Nutrition, 14 (2). pp. 137-150. ISSN 1394-035X http://nutriweb.org.my/publications/mjn0014_2/mjn14n2_art2.php English
spellingShingle Haniff, Jamaiyah
Appannah, Geeta
Mohammad Nor, Noor Safiza
Wong, N. F.
Kee, Chee Cheong
Zainuddin, Ahmad Ali
Shahar, Suzana
Rasat, Rahmah
Khor, Geok Lin
Abd Talib, Ruzita
Chen, Won Sun
M., Rajaah
Yusoff, Ahmad Faudzi
Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia
title Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia
title_full Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia
title_fullStr Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia
title_full_unstemmed Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia
title_short Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia
title_sort reliability and technical error of calf circumference and mid half arm span measurements for nutritional status assessment of elderly persons in malaysia
url http://psasir.upm.edu.my/id/eprint/6490/1/mjn14n2_art2.pdf
work_keys_str_mv AT haniffjamaiyah reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia
AT appannahgeeta reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia
AT mohammadnornoorsafiza reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia
AT wongnf reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia
AT keecheecheong reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia
AT zainuddinahmadali reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia
AT shaharsuzana reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia
AT rasatrahmah reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia
AT khorgeoklin reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia
AT abdtalibruzita reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia
AT chenwonsun reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia
AT mrajaah reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia
AT yusoffahmadfaudzi reliabilityandtechnicalerrorofcalfcircumferenceandmidhalfarmspanmeasurementsfornutritionalstatusassessmentofelderlypersonsinmalaysia