Minimum separation between lightning protection system and non-integrated metallic structures

In the event of a direct lightning strike to a protected building which is integrated with an electrical or electronic system installed on the roof such as roof-top PV system, dangerous arcing may occur between the external lightning protection system (LPS) and the conductive components of the elect...

Full description

Bibliographic Details
Main Authors: Fallah, Seyedeh Narjes, Gomes, Chandima, Izadi, Mahdi, Ab Kadir, Mohd Zainal Abidin, Ahmed, Rebaz Jamal, Jasni, Jasronita
Format: Conference or Workshop Item
Language:English
Published: IEEE 2018
Online Access:http://psasir.upm.edu.my/id/eprint/68198/1/Minimum%20separation%20between%20lightning%20protection%20system%20and%20non-integrated%20metallic%20structures.pdf
_version_ 1796978670768750592
author Fallah, Seyedeh Narjes
Gomes, Chandima
Izadi, Mahdi
Ab Kadir, Mohd Zainal Abidin
Ahmed, Rebaz Jamal
Jasni, Jasronita
author_facet Fallah, Seyedeh Narjes
Gomes, Chandima
Izadi, Mahdi
Ab Kadir, Mohd Zainal Abidin
Ahmed, Rebaz Jamal
Jasni, Jasronita
author_sort Fallah, Seyedeh Narjes
collection UPM
description In the event of a direct lightning strike to a protected building which is integrated with an electrical or electronic system installed on the roof such as roof-top PV system, dangerous arcing may occur between the external lightning protection system (LPS) and the conductive components of the electrical system. To prevent such side flashes, a minimum separation distance between the metallic components and the air termination system is required. Even though, IEC62305-3 Standard provides a formula to specify the necessary separation distance, so far there is no extensive study that has been done to evaluate the suitability of the application of equation to calculate the separation distance, specifically to the safety of electrical systems integrated into the roof top of building. In this study, a new computational method has been developed for calculation of the separation distance between an LPS and metallic components on the roof. In the proposed method which is based on the theoretical background of the IEC62305-3 Standard formula, the break down behavior of the gap geometry between the LPS and the metallic components for the applied voltage across the gap is analyzed. PSCAD software was used to model the LPS and the lightning strokes.
first_indexed 2024-03-06T09:57:54Z
format Conference or Workshop Item
id upm.eprints-68198
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T09:57:54Z
publishDate 2018
publisher IEEE
record_format dspace
spelling upm.eprints-681982019-05-09T03:39:04Z http://psasir.upm.edu.my/id/eprint/68198/ Minimum separation between lightning protection system and non-integrated metallic structures Fallah, Seyedeh Narjes Gomes, Chandima Izadi, Mahdi Ab Kadir, Mohd Zainal Abidin Ahmed, Rebaz Jamal Jasni, Jasronita In the event of a direct lightning strike to a protected building which is integrated with an electrical or electronic system installed on the roof such as roof-top PV system, dangerous arcing may occur between the external lightning protection system (LPS) and the conductive components of the electrical system. To prevent such side flashes, a minimum separation distance between the metallic components and the air termination system is required. Even though, IEC62305-3 Standard provides a formula to specify the necessary separation distance, so far there is no extensive study that has been done to evaluate the suitability of the application of equation to calculate the separation distance, specifically to the safety of electrical systems integrated into the roof top of building. In this study, a new computational method has been developed for calculation of the separation distance between an LPS and metallic components on the roof. In the proposed method which is based on the theoretical background of the IEC62305-3 Standard formula, the break down behavior of the gap geometry between the LPS and the metallic components for the applied voltage across the gap is analyzed. PSCAD software was used to model the LPS and the lightning strokes. IEEE 2018 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/68198/1/Minimum%20separation%20between%20lightning%20protection%20system%20and%20non-integrated%20metallic%20structures.pdf Fallah, Seyedeh Narjes and Gomes, Chandima and Izadi, Mahdi and Ab Kadir, Mohd Zainal Abidin and Ahmed, Rebaz Jamal and Jasni, Jasronita (2018) Minimum separation between lightning protection system and non-integrated metallic structures. In: 34th International Conference on Lightning Protection (ICLP 2018), 2-7 Sept. 2018, Rzeszow, Poland. . 10.1109/ICLP.2018.8503276
spellingShingle Fallah, Seyedeh Narjes
Gomes, Chandima
Izadi, Mahdi
Ab Kadir, Mohd Zainal Abidin
Ahmed, Rebaz Jamal
Jasni, Jasronita
Minimum separation between lightning protection system and non-integrated metallic structures
title Minimum separation between lightning protection system and non-integrated metallic structures
title_full Minimum separation between lightning protection system and non-integrated metallic structures
title_fullStr Minimum separation between lightning protection system and non-integrated metallic structures
title_full_unstemmed Minimum separation between lightning protection system and non-integrated metallic structures
title_short Minimum separation between lightning protection system and non-integrated metallic structures
title_sort minimum separation between lightning protection system and non integrated metallic structures
url http://psasir.upm.edu.my/id/eprint/68198/1/Minimum%20separation%20between%20lightning%20protection%20system%20and%20non-integrated%20metallic%20structures.pdf
work_keys_str_mv AT fallahseyedehnarjes minimumseparationbetweenlightningprotectionsystemandnonintegratedmetallicstructures
AT gomeschandima minimumseparationbetweenlightningprotectionsystemandnonintegratedmetallicstructures
AT izadimahdi minimumseparationbetweenlightningprotectionsystemandnonintegratedmetallicstructures
AT abkadirmohdzainalabidin minimumseparationbetweenlightningprotectionsystemandnonintegratedmetallicstructures
AT ahmedrebazjamal minimumseparationbetweenlightningprotectionsystemandnonintegratedmetallicstructures
AT jasnijasronita minimumseparationbetweenlightningprotectionsystemandnonintegratedmetallicstructures