S-band five-port ring reflectometer-probe system for in vitro breast tumor detection
A five-port ring reflectometer-probe system was developed to measure relative permittivity of normal and tumorous breast tissues in frequency range from 1.6 to 2.75 GHz. The calibration procedures of the study reflectometer and the coaxial probe were described in detail. In this study, the synthetic...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2018
|
Online Access: | http://psasir.upm.edu.my/id/eprint/73829/1/BAND.pdf |
_version_ | 1825950256583409664 |
---|---|
author | Lee, Chia Yew Kok, Yeow You Abbas, Zulkifly Lee, Kim Yee Lee, Yeng Seng Cheng, Ee Meng |
author_facet | Lee, Chia Yew Kok, Yeow You Abbas, Zulkifly Lee, Kim Yee Lee, Yeng Seng Cheng, Ee Meng |
author_sort | Lee, Chia Yew |
collection | UPM |
description | A five-port ring reflectometer-probe system was developed to measure relative permittivity of normal and tumorous breast tissues in frequency range from 1.6 to 2.75 GHz. The calibration procedures of the study reflectometer and the coaxial probe were described in detail. In this study, the synthetic breast tissues have been used, which are the Triton TX-100-water mixture at different ratios that mimic dielectric properties of normal and tumor breast tissue samples. The comparative studies of reflection coefficient and dielectric properties of the synthetic mixture samples were conducted using study reflectometer-probe system and commercial vector network analyzer with Keysight (formerly Agilent) 85070E dielectric probe. Maximum mean errors of the linear magnitude, phase, dielectric, and loss factor measurements were recorded to be 0.02, 6.1°, 2.21, and 1.60, respectively. These measurements were significantly distinguishable for normal and tumorous breast tissues. |
first_indexed | 2024-03-06T10:11:52Z |
format | Article |
id | upm.eprints-73829 |
institution | Universiti Putra Malaysia |
language | English |
last_indexed | 2024-03-06T10:11:52Z |
publishDate | 2018 |
publisher | Wiley |
record_format | dspace |
spelling | upm.eprints-738292021-07-17T23:43:53Z http://psasir.upm.edu.my/id/eprint/73829/ S-band five-port ring reflectometer-probe system for in vitro breast tumor detection Lee, Chia Yew Kok, Yeow You Abbas, Zulkifly Lee, Kim Yee Lee, Yeng Seng Cheng, Ee Meng A five-port ring reflectometer-probe system was developed to measure relative permittivity of normal and tumorous breast tissues in frequency range from 1.6 to 2.75 GHz. The calibration procedures of the study reflectometer and the coaxial probe were described in detail. In this study, the synthetic breast tissues have been used, which are the Triton TX-100-water mixture at different ratios that mimic dielectric properties of normal and tumor breast tissue samples. The comparative studies of reflection coefficient and dielectric properties of the synthetic mixture samples were conducted using study reflectometer-probe system and commercial vector network analyzer with Keysight (formerly Agilent) 85070E dielectric probe. Maximum mean errors of the linear magnitude, phase, dielectric, and loss factor measurements were recorded to be 0.02, 6.1°, 2.21, and 1.60, respectively. These measurements were significantly distinguishable for normal and tumorous breast tissues. Wiley 2018-03 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/73829/1/BAND.pdf Lee, Chia Yew and Kok, Yeow You and Abbas, Zulkifly and Lee, Kim Yee and Lee, Yeng Seng and Cheng, Ee Meng (2018) S-band five-port ring reflectometer-probe system for in vitro breast tumor detection. International Journal of RF and Microwave Computer-Aided Engineering, 28 (3). pp. 1-13. ISSN 1096-4290; ESSN: 1099-047X https://onlinelibrary.wiley.com/doi/abs/10.1002/mmce.21198 10.1002/mmce.21198 |
spellingShingle | Lee, Chia Yew Kok, Yeow You Abbas, Zulkifly Lee, Kim Yee Lee, Yeng Seng Cheng, Ee Meng S-band five-port ring reflectometer-probe system for in vitro breast tumor detection |
title | S-band five-port ring reflectometer-probe system for in vitro breast tumor detection |
title_full | S-band five-port ring reflectometer-probe system for in vitro breast tumor detection |
title_fullStr | S-band five-port ring reflectometer-probe system for in vitro breast tumor detection |
title_full_unstemmed | S-band five-port ring reflectometer-probe system for in vitro breast tumor detection |
title_short | S-band five-port ring reflectometer-probe system for in vitro breast tumor detection |
title_sort | s band five port ring reflectometer probe system for in vitro breast tumor detection |
url | http://psasir.upm.edu.my/id/eprint/73829/1/BAND.pdf |
work_keys_str_mv | AT leechiayew sbandfiveportringreflectometerprobesystemforinvitrobreasttumordetection AT kokyeowyou sbandfiveportringreflectometerprobesystemforinvitrobreasttumordetection AT abbaszulkifly sbandfiveportringreflectometerprobesystemforinvitrobreasttumordetection AT leekimyee sbandfiveportringreflectometerprobesystemforinvitrobreasttumordetection AT leeyengseng sbandfiveportringreflectometerprobesystemforinvitrobreasttumordetection AT chengeemeng sbandfiveportringreflectometerprobesystemforinvitrobreasttumordetection |