Comparative analysis of ACSR and ACCC conductors on corona effect for lightning surge studies

Corona effect plays an important role in determining the distortion and attenuation of the surges travelling along overhead transmission lines and thus could possibly cause the backflashover. This this paper presents a comparative analysis between the two conductors used for 275 kV transmission line...

Full description

Bibliographic Details
Main Authors: Mohd Nawi, Zawati, Ab Kadir, Mohd Zainal Abidin, Azis, Norhafiz, Wan Ahmad, Wan Fatinhamamah, Mohamed Rawi, Iryani, Ungku Amirulddin Al Amin, Ungku Anisa, Nordin, Farah Hani
Format: Conference or Workshop Item
Language:English
Published: IEEE 2019
Online Access:http://psasir.upm.edu.my/id/eprint/78150/1/Comparative%20analysis%20of%20ACSR%20and%20ACCC%20conductors%20on%20corona%20effect%20for%20lightning%20surge%20studies.pdf
_version_ 1796980430055931904
author Mohd Nawi, Zawati
Ab Kadir, Mohd Zainal Abidin
Azis, Norhafiz
Wan Ahmad, Wan Fatinhamamah
Mohamed Rawi, Iryani
Ungku Amirulddin Al Amin, Ungku Anisa
Nordin, Farah Hani
author_facet Mohd Nawi, Zawati
Ab Kadir, Mohd Zainal Abidin
Azis, Norhafiz
Wan Ahmad, Wan Fatinhamamah
Mohamed Rawi, Iryani
Ungku Amirulddin Al Amin, Ungku Anisa
Nordin, Farah Hani
author_sort Mohd Nawi, Zawati
collection UPM
description Corona effect plays an important role in determining the distortion and attenuation of the surges travelling along overhead transmission lines and thus could possibly cause the backflashover. This this paper presents a comparative analysis between the two conductors used for 275 kV transmission line in term of corona effect when subjected to the lightning surge propagation studies. The two conductors are the Aluminium Conductor Steel Reinforced (ACSR) and the new High-Temperature Low Sag (HTLS) conductor, known as Aluminium Conductor Composite Core (ACCC). Simulation using section by section method for a single conductor were simulated using PSCAD/EMTDC software. The analyses were done by comparing the results with three parameters that known to be affected the corona, namely the different conductor radius, the heights of the conductor above ground level, and the segment length used for a single conductor. The finding that can be drawn from the study is that the presence of ACCC conductor are found to be more efficient in reducing the corona effect than the ACSR conductors apart from other advantages such as higher current capacity and lesser losses as compared to ACSR.
first_indexed 2024-03-06T10:22:53Z
format Conference or Workshop Item
id upm.eprints-78150
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T10:22:53Z
publishDate 2019
publisher IEEE
record_format dspace
spelling upm.eprints-781502020-06-15T06:32:36Z http://psasir.upm.edu.my/id/eprint/78150/ Comparative analysis of ACSR and ACCC conductors on corona effect for lightning surge studies Mohd Nawi, Zawati Ab Kadir, Mohd Zainal Abidin Azis, Norhafiz Wan Ahmad, Wan Fatinhamamah Mohamed Rawi, Iryani Ungku Amirulddin Al Amin, Ungku Anisa Nordin, Farah Hani Corona effect plays an important role in determining the distortion and attenuation of the surges travelling along overhead transmission lines and thus could possibly cause the backflashover. This this paper presents a comparative analysis between the two conductors used for 275 kV transmission line in term of corona effect when subjected to the lightning surge propagation studies. The two conductors are the Aluminium Conductor Steel Reinforced (ACSR) and the new High-Temperature Low Sag (HTLS) conductor, known as Aluminium Conductor Composite Core (ACCC). Simulation using section by section method for a single conductor were simulated using PSCAD/EMTDC software. The analyses were done by comparing the results with three parameters that known to be affected the corona, namely the different conductor radius, the heights of the conductor above ground level, and the segment length used for a single conductor. The finding that can be drawn from the study is that the presence of ACCC conductor are found to be more efficient in reducing the corona effect than the ACSR conductors apart from other advantages such as higher current capacity and lesser losses as compared to ACSR. IEEE 2019 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/78150/1/Comparative%20analysis%20of%20ACSR%20and%20ACCC%20conductors%20on%20corona%20effect%20for%20lightning%20surge%20studies.pdf Mohd Nawi, Zawati and Ab Kadir, Mohd Zainal Abidin and Azis, Norhafiz and Wan Ahmad, Wan Fatinhamamah and Mohamed Rawi, Iryani and Ungku Amirulddin Al Amin, Ungku Anisa and Nordin, Farah Hani (2019) Comparative analysis of ACSR and ACCC conductors on corona effect for lightning surge studies. In: 11th Asia-Pacific International Conference on Lightning (APL 2019), 12-14 June 2019, Hong Kong, China. . 10.1109/APL.2019.8815963
spellingShingle Mohd Nawi, Zawati
Ab Kadir, Mohd Zainal Abidin
Azis, Norhafiz
Wan Ahmad, Wan Fatinhamamah
Mohamed Rawi, Iryani
Ungku Amirulddin Al Amin, Ungku Anisa
Nordin, Farah Hani
Comparative analysis of ACSR and ACCC conductors on corona effect for lightning surge studies
title Comparative analysis of ACSR and ACCC conductors on corona effect for lightning surge studies
title_full Comparative analysis of ACSR and ACCC conductors on corona effect for lightning surge studies
title_fullStr Comparative analysis of ACSR and ACCC conductors on corona effect for lightning surge studies
title_full_unstemmed Comparative analysis of ACSR and ACCC conductors on corona effect for lightning surge studies
title_short Comparative analysis of ACSR and ACCC conductors on corona effect for lightning surge studies
title_sort comparative analysis of acsr and accc conductors on corona effect for lightning surge studies
url http://psasir.upm.edu.my/id/eprint/78150/1/Comparative%20analysis%20of%20ACSR%20and%20ACCC%20conductors%20on%20corona%20effect%20for%20lightning%20surge%20studies.pdf
work_keys_str_mv AT mohdnawizawati comparativeanalysisofacsrandacccconductorsoncoronaeffectforlightningsurgestudies
AT abkadirmohdzainalabidin comparativeanalysisofacsrandacccconductorsoncoronaeffectforlightningsurgestudies
AT azisnorhafiz comparativeanalysisofacsrandacccconductorsoncoronaeffectforlightningsurgestudies
AT wanahmadwanfatinhamamah comparativeanalysisofacsrandacccconductorsoncoronaeffectforlightningsurgestudies
AT mohamedrawiiryani comparativeanalysisofacsrandacccconductorsoncoronaeffectforlightningsurgestudies
AT ungkuamirulddinalaminungkuanisa comparativeanalysisofacsrandacccconductorsoncoronaeffectforlightningsurgestudies
AT nordinfarahhani comparativeanalysisofacsrandacccconductorsoncoronaeffectforlightningsurgestudies