Comparison of dose calculation algorithms model: convolution, superposition, and fast superposition in 3-D Conformal Radiotherapy (3D-CRT) treatment plan

The important task of radiotherapy is to make sure that the radiation dose to the target tumour is accurate as prescribed and the dose to the organ at risk is minimized. Therefore, the aim of this study is to compare and evaluate the efficiency of the dose calculation algorithms: namely convolution,...

Full description

Bibliographic Details
Main Authors: Murat, Husain, Abdul Karim, Muhammad Khalis, Haspiharun, Hanif, Kayun, Zunaide
Format: Article
Language:English
Published: Institute of Physics Publishing 2019
Online Access:http://psasir.upm.edu.my/id/eprint/80983/1/CALC.pdf
_version_ 1825951367655587840
author Murat, Husain
Abdul Karim, Muhammad Khalis
Haspiharun, Hanif
Kayun, Zunaide
author_facet Murat, Husain
Abdul Karim, Muhammad Khalis
Haspiharun, Hanif
Kayun, Zunaide
author_sort Murat, Husain
collection UPM
description The important task of radiotherapy is to make sure that the radiation dose to the target tumour is accurate as prescribed and the dose to the organ at risk is minimized. Therefore, the aim of this study is to compare and evaluate the efficiency of the dose calculation algorithms: namely convolution, superposition, and fast superposition which installed in Treatment Planning System (TPS) (CMS XiO, USA). In this study, we modified protocols described in IAEATecdoc-1583, where four typical treatment techniques such as single field, multiple field, wedge field, and multi-leaf collimated (MLC) field were analysed from the system. The measurement data for calculated dose and measured dose were taken from thorax CIRS anthropomorphic phantom. The assessment of algorithms was done by comparing the point dose calculated with the measured dose. The study shows that the superposition algorithm produced relative error less than ±3% which passed 100% of all reference points, whilst the convolution algorithm and fast superposition presented relative error more than ±3% which passed 82% and 91% of reference points, respectively. In conclusion, the evaluation of radiotherapy treatment plan shall take into account the type of dose calculation algorithm model in order to optimize radiotherapy treatment and ensure the radiation safety to the patient.
first_indexed 2024-03-06T10:28:57Z
format Article
id upm.eprints-80983
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T10:28:57Z
publishDate 2019
publisher Institute of Physics Publishing
record_format dspace
spelling upm.eprints-809832020-10-14T20:45:27Z http://psasir.upm.edu.my/id/eprint/80983/ Comparison of dose calculation algorithms model: convolution, superposition, and fast superposition in 3-D Conformal Radiotherapy (3D-CRT) treatment plan Murat, Husain Abdul Karim, Muhammad Khalis Haspiharun, Hanif Kayun, Zunaide The important task of radiotherapy is to make sure that the radiation dose to the target tumour is accurate as prescribed and the dose to the organ at risk is minimized. Therefore, the aim of this study is to compare and evaluate the efficiency of the dose calculation algorithms: namely convolution, superposition, and fast superposition which installed in Treatment Planning System (TPS) (CMS XiO, USA). In this study, we modified protocols described in IAEATecdoc-1583, where four typical treatment techniques such as single field, multiple field, wedge field, and multi-leaf collimated (MLC) field were analysed from the system. The measurement data for calculated dose and measured dose were taken from thorax CIRS anthropomorphic phantom. The assessment of algorithms was done by comparing the point dose calculated with the measured dose. The study shows that the superposition algorithm produced relative error less than ±3% which passed 100% of all reference points, whilst the convolution algorithm and fast superposition presented relative error more than ±3% which passed 82% and 91% of reference points, respectively. In conclusion, the evaluation of radiotherapy treatment plan shall take into account the type of dose calculation algorithm model in order to optimize radiotherapy treatment and ensure the radiation safety to the patient. Institute of Physics Publishing 2019 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/80983/1/CALC.pdf Murat, Husain and Abdul Karim, Muhammad Khalis and Haspiharun, Hanif and Kayun, Zunaide (2019) Comparison of dose calculation algorithms model: convolution, superposition, and fast superposition in 3-D Conformal Radiotherapy (3D-CRT) treatment plan. Journal of Physics: Conference Series, 1248. art. no. 012047. pp. 1-6. ISSN 1742-6588; ESSN: 1742-6596 https://iopscience.iop.org/article/10.1088/1742-6596/1248/1/012047/pdf 10.1088/1742-6596/1248/1/012047
spellingShingle Murat, Husain
Abdul Karim, Muhammad Khalis
Haspiharun, Hanif
Kayun, Zunaide
Comparison of dose calculation algorithms model: convolution, superposition, and fast superposition in 3-D Conformal Radiotherapy (3D-CRT) treatment plan
title Comparison of dose calculation algorithms model: convolution, superposition, and fast superposition in 3-D Conformal Radiotherapy (3D-CRT) treatment plan
title_full Comparison of dose calculation algorithms model: convolution, superposition, and fast superposition in 3-D Conformal Radiotherapy (3D-CRT) treatment plan
title_fullStr Comparison of dose calculation algorithms model: convolution, superposition, and fast superposition in 3-D Conformal Radiotherapy (3D-CRT) treatment plan
title_full_unstemmed Comparison of dose calculation algorithms model: convolution, superposition, and fast superposition in 3-D Conformal Radiotherapy (3D-CRT) treatment plan
title_short Comparison of dose calculation algorithms model: convolution, superposition, and fast superposition in 3-D Conformal Radiotherapy (3D-CRT) treatment plan
title_sort comparison of dose calculation algorithms model convolution superposition and fast superposition in 3 d conformal radiotherapy 3d crt treatment plan
url http://psasir.upm.edu.my/id/eprint/80983/1/CALC.pdf
work_keys_str_mv AT murathusain comparisonofdosecalculationalgorithmsmodelconvolutionsuperpositionandfastsuperpositionin3dconformalradiotherapy3dcrttreatmentplan
AT abdulkarimmuhammadkhalis comparisonofdosecalculationalgorithmsmodelconvolutionsuperpositionandfastsuperpositionin3dconformalradiotherapy3dcrttreatmentplan
AT haspiharunhanif comparisonofdosecalculationalgorithmsmodelconvolutionsuperpositionandfastsuperpositionin3dconformalradiotherapy3dcrttreatmentplan
AT kayunzunaide comparisonofdosecalculationalgorithmsmodelconvolutionsuperpositionandfastsuperpositionin3dconformalradiotherapy3dcrttreatmentplan