Optimisation and validation of ultrahigh performance liquid chromatography method for quantification of 25-hydroxyvitamin d in maternal plasma

This study aimed to optimise and validate a simple and efficient sample preparation and extraction method for the quantification of 25-hydroxyvitamin D (25OHD) in the maternal plasma sample. Different sample preparation methods and precipitation reagentto sample ratio used by previous studies were c...

Full description

Bibliographic Details
Main Authors: Lee, Siew Siew, Loh, Su Peng
Format: Article
Language:English
Published: Malaysian Analytical Sciences Society 2020
Online Access:http://psasir.upm.edu.my/id/eprint/86998/1/Optimisation%20and%20validation%20of%20ultrahigh%20performance%20liquid%20chromatography.pdf
_version_ 1796981794317271040
author Lee, Siew Siew
Loh, Su Peng
author_facet Lee, Siew Siew
Loh, Su Peng
author_sort Lee, Siew Siew
collection UPM
description This study aimed to optimise and validate a simple and efficient sample preparation and extraction method for the quantification of 25-hydroxyvitamin D (25OHD) in the maternal plasma sample. Different sample preparation methods and precipitation reagentto sample ratio used by previous studies were compared. An ultrahigh performance liquid chromatography method was developed and validated for simultaneous quantification of 25OHD2 and 25OHD3. The chromatographic separation was achieved using the COSMOCORE 2.6Cholester Column and methanol and 0.1% formic acid (79:21, %v/v) as mobile phase at a flow rate of 0.3 mL/min and diode array detection at 264 nm. The results demonstrated that a recovery of approximately 100% could be achieved by extracting samples using 1 mL of hexane, vortex for 10s and a total number of three extraction steps. The precipitation reagentto-sample ratio of 2.8 was optimum for the quantification of 25OHD2 and 25OHD3 in a pooled maternal sample. The value obtained for validation parameters meets the criteria of the Recommendations and Acceptance Criteria for Bioanalytical Method Validation by the Food and Drug Administration. The results showed that this method could be applied for routine quantification of 25OHD, particularly in the maternal plasma sample.
first_indexed 2024-03-06T10:42:52Z
format Article
id upm.eprints-86998
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T10:42:52Z
publishDate 2020
publisher Malaysian Analytical Sciences Society
record_format dspace
spelling upm.eprints-869982022-09-05T02:11:34Z http://psasir.upm.edu.my/id/eprint/86998/ Optimisation and validation of ultrahigh performance liquid chromatography method for quantification of 25-hydroxyvitamin d in maternal plasma Lee, Siew Siew Loh, Su Peng This study aimed to optimise and validate a simple and efficient sample preparation and extraction method for the quantification of 25-hydroxyvitamin D (25OHD) in the maternal plasma sample. Different sample preparation methods and precipitation reagentto sample ratio used by previous studies were compared. An ultrahigh performance liquid chromatography method was developed and validated for simultaneous quantification of 25OHD2 and 25OHD3. The chromatographic separation was achieved using the COSMOCORE 2.6Cholester Column and methanol and 0.1% formic acid (79:21, %v/v) as mobile phase at a flow rate of 0.3 mL/min and diode array detection at 264 nm. The results demonstrated that a recovery of approximately 100% could be achieved by extracting samples using 1 mL of hexane, vortex for 10s and a total number of three extraction steps. The precipitation reagentto-sample ratio of 2.8 was optimum for the quantification of 25OHD2 and 25OHD3 in a pooled maternal sample. The value obtained for validation parameters meets the criteria of the Recommendations and Acceptance Criteria for Bioanalytical Method Validation by the Food and Drug Administration. The results showed that this method could be applied for routine quantification of 25OHD, particularly in the maternal plasma sample. Malaysian Analytical Sciences Society 2020-12-10 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/86998/1/Optimisation%20and%20validation%20of%20ultrahigh%20performance%20liquid%20chromatography.pdf Lee, Siew Siew and Loh, Su Peng (2020) Optimisation and validation of ultrahigh performance liquid chromatography method for quantification of 25-hydroxyvitamin d in maternal plasma. Malaysian Journal of Analytical Sciences, 24 (6). 927 - 939. ISSN 1394-2506 https://mjas.analis.com.my/mjas/v24_n6/html/24_6_12.html
spellingShingle Lee, Siew Siew
Loh, Su Peng
Optimisation and validation of ultrahigh performance liquid chromatography method for quantification of 25-hydroxyvitamin d in maternal plasma
title Optimisation and validation of ultrahigh performance liquid chromatography method for quantification of 25-hydroxyvitamin d in maternal plasma
title_full Optimisation and validation of ultrahigh performance liquid chromatography method for quantification of 25-hydroxyvitamin d in maternal plasma
title_fullStr Optimisation and validation of ultrahigh performance liquid chromatography method for quantification of 25-hydroxyvitamin d in maternal plasma
title_full_unstemmed Optimisation and validation of ultrahigh performance liquid chromatography method for quantification of 25-hydroxyvitamin d in maternal plasma
title_short Optimisation and validation of ultrahigh performance liquid chromatography method for quantification of 25-hydroxyvitamin d in maternal plasma
title_sort optimisation and validation of ultrahigh performance liquid chromatography method for quantification of 25 hydroxyvitamin d in maternal plasma
url http://psasir.upm.edu.my/id/eprint/86998/1/Optimisation%20and%20validation%20of%20ultrahigh%20performance%20liquid%20chromatography.pdf
work_keys_str_mv AT leesiewsiew optimisationandvalidationofultrahighperformanceliquidchromatographymethodforquantificationof25hydroxyvitamindinmaternalplasma
AT lohsupeng optimisationandvalidationofultrahighperformanceliquidchromatographymethodforquantificationof25hydroxyvitamindinmaternalplasma