Backscattering factor measurements of gamma rays of the different thickness of pure concrete

Backscattering peak is one of the main features of the pulse height spectrum from a gamma ray detector. This arises mainly from materials outside like source baking, photomultiplier tube housing, shielding etc. The effect of source backing on the relative importance of the backscattered peak for...

Full description

Bibliographic Details
Main Author: Almayahi, B.A.
Format: Article
Published: Elsevier 2015
Subjects:
_version_ 1825833842116657152
author Almayahi, B.A.
author_facet Almayahi, B.A.
author_sort Almayahi, B.A.
collection USM
description Backscattering peak is one of the main features of the pulse height spectrum from a gamma ray detector. This arises mainly from materials outside like source baking, photomultiplier tube housing, shielding etc. The effect of source backing on the relative importance of the backscattered peak for gamma ray using a NaI (Tl) scintillation detector is measured. Gamma energies in the range from 0.088 MeV to 1.253 MeV are used. Backscattering factor (Fb) measurements have been carried out (2 > Fb � 1) of various pure concrete thickness from 2 cm to 30 cm.
first_indexed 2024-03-06T15:13:51Z
format Article
id usm.eprints-38384
institution Universiti Sains Malaysia
last_indexed 2024-03-06T15:13:51Z
publishDate 2015
publisher Elsevier
record_format dspace
spelling usm.eprints-383842018-01-16T03:42:36Z http://eprints.usm.my/38384/ Backscattering factor measurements of gamma rays of the different thickness of pure concrete Almayahi, B.A. QC1-999 Physics Backscattering peak is one of the main features of the pulse height spectrum from a gamma ray detector. This arises mainly from materials outside like source baking, photomultiplier tube housing, shielding etc. The effect of source backing on the relative importance of the backscattered peak for gamma ray using a NaI (Tl) scintillation detector is measured. Gamma energies in the range from 0.088 MeV to 1.253 MeV are used. Backscattering factor (Fb) measurements have been carried out (2 > Fb � 1) of various pure concrete thickness from 2 cm to 30 cm. Elsevier 2015-07 Article PeerReviewed Almayahi, B.A. (2015) Backscattering factor measurements of gamma rays of the different thickness of pure concrete. Journal of Radiation Research and Applied Sciences, 8 (3). pp. 389-392. ISSN 1687-8507 https://doi.org/10.1016/j.jrras.2015.02.008
spellingShingle QC1-999 Physics
Almayahi, B.A.
Backscattering factor measurements of gamma rays of the different thickness of pure concrete
title Backscattering factor measurements of gamma rays of the different thickness of pure concrete
title_full Backscattering factor measurements of gamma rays of the different thickness of pure concrete
title_fullStr Backscattering factor measurements of gamma rays of the different thickness of pure concrete
title_full_unstemmed Backscattering factor measurements of gamma rays of the different thickness of pure concrete
title_short Backscattering factor measurements of gamma rays of the different thickness of pure concrete
title_sort backscattering factor measurements of gamma rays of the different thickness of pure concrete
topic QC1-999 Physics
work_keys_str_mv AT almayahiba backscatteringfactormeasurementsofgammaraysofthedifferentthicknessofpureconcrete