The optimal time for blood pressure measurement in end-stage renal failure patients on regular hemodialysis in Hospital University Sains Malaysia
Introduction: The appropriate time and method of blood pressure measurement in end stage renal failure (ESRF) patients on regular hemodialysis is still uncertain. During posthemodialysis, refilling of plasma volume from the interstitium took place. Therefore, the exact timing of when blood volume...
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2014
|
Subjects: | |
Online Access: | http://eprints.usm.my/39489/1/Dr._Kurnia_Prima_Sawai_Saurdi_%28Internal_Medicine_%29-24_pages.pdf |
_version_ | 1825834060727975936 |
---|---|
author | Suardi, Kurnia Prima Sawai |
author_facet | Suardi, Kurnia Prima Sawai |
author_sort | Suardi, Kurnia Prima Sawai |
collection | USM |
description | Introduction: The appropriate time and method of blood pressure measurement in end
stage renal failure (ESRF) patients on regular hemodialysis is still uncertain. During posthemodialysis,
refilling of plasma volume from the interstitium took place. Therefore, the
exact timing of when blood volume reaches equilibrates is uncertain. The inferior vena
cava diameter normalizes when patient is euvolemic. Therefore, ultrasonographic direct
measurement of inferior vena cava can be used to reflect the euvolemic state.
Objectives: To determine the best time to measure post-hemodialysis blood pressure in
ESRF patients on regular hemodialysis. To determine the variability of 24 hours blood
pressure readings.
Method: This is a cross sectional study involving 14 ESRF patients on regular
hemodialysis in the HUSM outpatient hemodialysis unit. Hourly blood pressure reading
was taken using ambulatory blood pressure monitoring device, starting from a day before
hemodialysis session and 4 hours of post-hemodialysis, total duration of 24 hours. Upon
completion of the hemodialysis treatment, serial ultrasonographic inferior vena cava
diameter measurements were performed at 10, 30 and 60 minutes post-hemodialysis.
Simultaneously, blood pressure readings were also taken at 10, 30 and 60 minutes posthemodialysis.
Results were expressed as median (interquartile range) for data that was not
normally distributed and described as mean (standard deviation) for normally distributed
data. Repeated measure ANOVA was used to test for significance of blood pressure
variability.
Results: The inferior vena cava diameter was small at 10 minutes post-hemodialysis but
it become normalize at 30 minutes and not much difference at 60 minutes. Blood pressure at 10, 30 and 60 minutes was found to be closer to average value at 60 minutes.
Variability of the average blood pressure was not significant.
Conclusions: The optimal time for blood pressure measurement in end stage renal failure
patients on regular hemodialysis was found to be at 60 minutes post-hemodialysis based
on euvolemic state reflected by IVC diameter. This study also found that there was no
significant difference in blood pressure variability from one person to another.
Keywords: end stage renal failure, hemodialysis, inferior vena cava diameter
|
first_indexed | 2024-03-06T15:17:04Z |
format | Thesis |
id | usm.eprints-39489 |
institution | Universiti Sains Malaysia |
language | English |
last_indexed | 2024-03-06T15:17:04Z |
publishDate | 2014 |
record_format | dspace |
spelling | usm.eprints-394892019-04-12T05:26:08Z http://eprints.usm.my/39489/ The optimal time for blood pressure measurement in end-stage renal failure patients on regular hemodialysis in Hospital University Sains Malaysia Suardi, Kurnia Prima Sawai RC666-701 Diseases of the circulatory (Cardiovascular) system Introduction: The appropriate time and method of blood pressure measurement in end stage renal failure (ESRF) patients on regular hemodialysis is still uncertain. During posthemodialysis, refilling of plasma volume from the interstitium took place. Therefore, the exact timing of when blood volume reaches equilibrates is uncertain. The inferior vena cava diameter normalizes when patient is euvolemic. Therefore, ultrasonographic direct measurement of inferior vena cava can be used to reflect the euvolemic state. Objectives: To determine the best time to measure post-hemodialysis blood pressure in ESRF patients on regular hemodialysis. To determine the variability of 24 hours blood pressure readings. Method: This is a cross sectional study involving 14 ESRF patients on regular hemodialysis in the HUSM outpatient hemodialysis unit. Hourly blood pressure reading was taken using ambulatory blood pressure monitoring device, starting from a day before hemodialysis session and 4 hours of post-hemodialysis, total duration of 24 hours. Upon completion of the hemodialysis treatment, serial ultrasonographic inferior vena cava diameter measurements were performed at 10, 30 and 60 minutes post-hemodialysis. Simultaneously, blood pressure readings were also taken at 10, 30 and 60 minutes posthemodialysis. Results were expressed as median (interquartile range) for data that was not normally distributed and described as mean (standard deviation) for normally distributed data. Repeated measure ANOVA was used to test for significance of blood pressure variability. Results: The inferior vena cava diameter was small at 10 minutes post-hemodialysis but it become normalize at 30 minutes and not much difference at 60 minutes. Blood pressure at 10, 30 and 60 minutes was found to be closer to average value at 60 minutes. Variability of the average blood pressure was not significant. Conclusions: The optimal time for blood pressure measurement in end stage renal failure patients on regular hemodialysis was found to be at 60 minutes post-hemodialysis based on euvolemic state reflected by IVC diameter. This study also found that there was no significant difference in blood pressure variability from one person to another. Keywords: end stage renal failure, hemodialysis, inferior vena cava diameter 2014 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/39489/1/Dr._Kurnia_Prima_Sawai_Saurdi_%28Internal_Medicine_%29-24_pages.pdf Suardi, Kurnia Prima Sawai (2014) The optimal time for blood pressure measurement in end-stage renal failure patients on regular hemodialysis in Hospital University Sains Malaysia. Masters thesis, Universiti Sains Malaysia. |
spellingShingle | RC666-701 Diseases of the circulatory (Cardiovascular) system Suardi, Kurnia Prima Sawai The optimal time for blood pressure measurement in end-stage renal failure patients on regular hemodialysis in Hospital University Sains Malaysia |
title | The optimal time for blood pressure measurement in end-stage renal failure patients on regular hemodialysis in Hospital University Sains Malaysia |
title_full | The optimal time for blood pressure measurement in end-stage renal failure patients on regular hemodialysis in Hospital University Sains Malaysia |
title_fullStr | The optimal time for blood pressure measurement in end-stage renal failure patients on regular hemodialysis in Hospital University Sains Malaysia |
title_full_unstemmed | The optimal time for blood pressure measurement in end-stage renal failure patients on regular hemodialysis in Hospital University Sains Malaysia |
title_short | The optimal time for blood pressure measurement in end-stage renal failure patients on regular hemodialysis in Hospital University Sains Malaysia |
title_sort | optimal time for blood pressure measurement in end stage renal failure patients on regular hemodialysis in hospital university sains malaysia |
topic | RC666-701 Diseases of the circulatory (Cardiovascular) system |
url | http://eprints.usm.my/39489/1/Dr._Kurnia_Prima_Sawai_Saurdi_%28Internal_Medicine_%29-24_pages.pdf |
work_keys_str_mv | AT suardikurniaprimasawai theoptimaltimeforbloodpressuremeasurementinendstagerenalfailurepatientsonregularhemodialysisinhospitaluniversitysainsmalaysia AT suardikurniaprimasawai optimaltimeforbloodpressuremeasurementinendstagerenalfailurepatientsonregularhemodialysisinhospitaluniversitysainsmalaysia |