Fabrication And Characterization Of Agar Based Anthropomorphic Ultrasound Breast Phantom
An anthropomorphic agar based breast phantom including tissue mimicking (TM) non adipose glandular tissue, TM fat and TM cyst was been fabricated. The fabricated phantom was characterized and the weight composition, temperature, frequency and time dependencies of the phantom were investigated. The...
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2012
|
Subjects: | |
Online Access: | http://eprints.usm.my/42550/1/SEYEDEH_PARISA_FOROOZANDEHASL.pdf |
_version_ | 1797010851772760064 |
---|---|
author | Foroozandehasl, Seyedeh Parisa |
author_facet | Foroozandehasl, Seyedeh Parisa |
author_sort | Foroozandehasl, Seyedeh Parisa |
collection | USM |
description | An anthropomorphic agar based breast phantom including tissue mimicking (TM) non adipose glandular tissue, TM fat and TM cyst was been fabricated. The fabricated phantom was characterized and the weight composition, temperature,
frequency and time dependencies of the phantom were investigated. The sound speed and attenuation coefficient were measured by using the transmission substitution
technique with three broadband transducers with 2.25, 5 and 10 MHz frequencies. Acoustic impedance, reflection coefficient and bulk modulus of fabricated breast phantom were also assessed. |
first_indexed | 2024-03-06T15:25:44Z |
format | Thesis |
id | usm.eprints-42550 |
institution | Universiti Sains Malaysia |
language | English |
last_indexed | 2024-03-06T15:25:44Z |
publishDate | 2012 |
record_format | dspace |
spelling | usm.eprints-425502019-04-12T05:26:22Z http://eprints.usm.my/42550/ Fabrication And Characterization Of Agar Based Anthropomorphic Ultrasound Breast Phantom Foroozandehasl, Seyedeh Parisa QC1 Physics (General) An anthropomorphic agar based breast phantom including tissue mimicking (TM) non adipose glandular tissue, TM fat and TM cyst was been fabricated. The fabricated phantom was characterized and the weight composition, temperature, frequency and time dependencies of the phantom were investigated. The sound speed and attenuation coefficient were measured by using the transmission substitution technique with three broadband transducers with 2.25, 5 and 10 MHz frequencies. Acoustic impedance, reflection coefficient and bulk modulus of fabricated breast phantom were also assessed. 2012-03 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/42550/1/SEYEDEH_PARISA_FOROOZANDEHASL.pdf Foroozandehasl, Seyedeh Parisa (2012) Fabrication And Characterization Of Agar Based Anthropomorphic Ultrasound Breast Phantom. Masters thesis, Universiti Sains Malaysia. |
spellingShingle | QC1 Physics (General) Foroozandehasl, Seyedeh Parisa Fabrication And Characterization Of Agar Based Anthropomorphic Ultrasound Breast Phantom |
title | Fabrication And Characterization Of Agar Based Anthropomorphic Ultrasound Breast Phantom
|
title_full | Fabrication And Characterization Of Agar Based Anthropomorphic Ultrasound Breast Phantom
|
title_fullStr | Fabrication And Characterization Of Agar Based Anthropomorphic Ultrasound Breast Phantom
|
title_full_unstemmed | Fabrication And Characterization Of Agar Based Anthropomorphic Ultrasound Breast Phantom
|
title_short | Fabrication And Characterization Of Agar Based Anthropomorphic Ultrasound Breast Phantom
|
title_sort | fabrication and characterization of agar based anthropomorphic ultrasound breast phantom |
topic | QC1 Physics (General) |
url | http://eprints.usm.my/42550/1/SEYEDEH_PARISA_FOROOZANDEHASL.pdf |
work_keys_str_mv | AT foroozandehaslseyedehparisa fabricationandcharacterizationofagarbasedanthropomorphicultrasoundbreastphantom |