Assessment Of Polychlorinated Dioxins/Furans In Ambient Air And Soil Samples From Selected Industrial Sites Using Palm Kernel Shell Activated Carbon In A Modified Sample Preparation Method

For the first time an assessment of dioxins/furans in ambient air and soil samples in Malaysian environment is reported. Three (3) industrial sites and one (1) pristine site were selected for this study and samples were analysed using a modified sample preparation method. The analysis involves the q...

Full description

Bibliographic Details
Main Author: Ahmad, Abdul Rahim
Format: Thesis
Language:English
Published: 2012
Subjects:
Online Access:http://eprints.usm.my/43434/1/ABDUL%20RAHIM%20BIN%20AHMAD_HJ.pdf
_version_ 1825834792713715712
author Ahmad, Abdul Rahim
author_facet Ahmad, Abdul Rahim
author_sort Ahmad, Abdul Rahim
collection USM
description For the first time an assessment of dioxins/furans in ambient air and soil samples in Malaysian environment is reported. Three (3) industrial sites and one (1) pristine site were selected for this study and samples were analysed using a modified sample preparation method. The analysis involves the quantification of seventeen congeners of dioxins/furans present in the ambient air and soil samples. The highest dioxins/furans concentrations in ambient air were found in Taiping area ranging from 0.056 to 0.167 i-TEQ pg/Nm3. This was followed by Bukit Pelanduk area with dioxins/furans concentrations ranging from 0.080 I-TEQ to 0.113 i-TEQ pg/Nm3. The third site, which is in the Prai area recorded the lowest dioxins/furans concentrations, ranging from 0.029 to 0.099 i-TEQ pg/Nm3, while the pristine site in Kuala Tahan National Park area recorded the dioxins/furans concentration in the range of 0.003 to 0.006 i-TEQ pg/Nm3. The most abundant congeners in all air samples in these areas were 2,3,4,7,8 – PeCDF and 1,2,3,7,8 – PeCDD. This study also allows the prediction of dioxins/furans emission rate of different incinerator stacks by data fitting of the observed ambient air dioxins/furans concentration in the Gaussian air dispersion model. Other interesting finding in this study was that during periods of haze, it is evident that there is a correlation between the particulate matter concentrations (indicated by Air Pollution Index) and dioxins/furans concentrations in air. Wind speed and prevailing wind directions were found to contribute to the distributions of dioxins/furans emitted from incinerators to different distances.
first_indexed 2024-03-06T15:28:01Z
format Thesis
id usm.eprints-43434
institution Universiti Sains Malaysia
language English
last_indexed 2024-03-06T15:28:01Z
publishDate 2012
record_format dspace
spelling usm.eprints-434342019-04-12T05:26:24Z http://eprints.usm.my/43434/ Assessment Of Polychlorinated Dioxins/Furans In Ambient Air And Soil Samples From Selected Industrial Sites Using Palm Kernel Shell Activated Carbon In A Modified Sample Preparation Method Ahmad, Abdul Rahim RS1-441 Pharmacy and materia medica For the first time an assessment of dioxins/furans in ambient air and soil samples in Malaysian environment is reported. Three (3) industrial sites and one (1) pristine site were selected for this study and samples were analysed using a modified sample preparation method. The analysis involves the quantification of seventeen congeners of dioxins/furans present in the ambient air and soil samples. The highest dioxins/furans concentrations in ambient air were found in Taiping area ranging from 0.056 to 0.167 i-TEQ pg/Nm3. This was followed by Bukit Pelanduk area with dioxins/furans concentrations ranging from 0.080 I-TEQ to 0.113 i-TEQ pg/Nm3. The third site, which is in the Prai area recorded the lowest dioxins/furans concentrations, ranging from 0.029 to 0.099 i-TEQ pg/Nm3, while the pristine site in Kuala Tahan National Park area recorded the dioxins/furans concentration in the range of 0.003 to 0.006 i-TEQ pg/Nm3. The most abundant congeners in all air samples in these areas were 2,3,4,7,8 – PeCDF and 1,2,3,7,8 – PeCDD. This study also allows the prediction of dioxins/furans emission rate of different incinerator stacks by data fitting of the observed ambient air dioxins/furans concentration in the Gaussian air dispersion model. Other interesting finding in this study was that during periods of haze, it is evident that there is a correlation between the particulate matter concentrations (indicated by Air Pollution Index) and dioxins/furans concentrations in air. Wind speed and prevailing wind directions were found to contribute to the distributions of dioxins/furans emitted from incinerators to different distances. 2012 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/43434/1/ABDUL%20RAHIM%20BIN%20AHMAD_HJ.pdf Ahmad, Abdul Rahim (2012) Assessment Of Polychlorinated Dioxins/Furans In Ambient Air And Soil Samples From Selected Industrial Sites Using Palm Kernel Shell Activated Carbon In A Modified Sample Preparation Method. PhD thesis, Universiti Sains Malaysia.
spellingShingle RS1-441 Pharmacy and materia medica
Ahmad, Abdul Rahim
Assessment Of Polychlorinated Dioxins/Furans In Ambient Air And Soil Samples From Selected Industrial Sites Using Palm Kernel Shell Activated Carbon In A Modified Sample Preparation Method
title Assessment Of Polychlorinated Dioxins/Furans In Ambient Air And Soil Samples From Selected Industrial Sites Using Palm Kernel Shell Activated Carbon In A Modified Sample Preparation Method
title_full Assessment Of Polychlorinated Dioxins/Furans In Ambient Air And Soil Samples From Selected Industrial Sites Using Palm Kernel Shell Activated Carbon In A Modified Sample Preparation Method
title_fullStr Assessment Of Polychlorinated Dioxins/Furans In Ambient Air And Soil Samples From Selected Industrial Sites Using Palm Kernel Shell Activated Carbon In A Modified Sample Preparation Method
title_full_unstemmed Assessment Of Polychlorinated Dioxins/Furans In Ambient Air And Soil Samples From Selected Industrial Sites Using Palm Kernel Shell Activated Carbon In A Modified Sample Preparation Method
title_short Assessment Of Polychlorinated Dioxins/Furans In Ambient Air And Soil Samples From Selected Industrial Sites Using Palm Kernel Shell Activated Carbon In A Modified Sample Preparation Method
title_sort assessment of polychlorinated dioxins furans in ambient air and soil samples from selected industrial sites using palm kernel shell activated carbon in a modified sample preparation method
topic RS1-441 Pharmacy and materia medica
url http://eprints.usm.my/43434/1/ABDUL%20RAHIM%20BIN%20AHMAD_HJ.pdf
work_keys_str_mv AT ahmadabdulrahim assessmentofpolychlorinateddioxinsfuransinambientairandsoilsamplesfromselectedindustrialsitesusingpalmkernelshellactivatedcarboninamodifiedsamplepreparationmethod