Self-Biased Folded Cascode Instrumentation Amplifier Using Chopper Technique For Ecg

In twenty-first century, it has been witness the tremendous growth of technology in biomedical recording application particularly electrocardiogram (ECG) recording system and has had a profound impact on our daily life. The conventional ECG monitoring systems that are too bulky in nature which restr...

Full description

Bibliographic Details
Main Author: Lau, Jun Giap
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:http://eprints.usm.my/45778/1/Self-Biased%20Folded%20Cascode%20Instrumentation%20Amplifier%20Using%20Chopper%20Technique%20For%20Ecg.pdf
_version_ 1825835216984342528
author Lau, Jun Giap
author_facet Lau, Jun Giap
author_sort Lau, Jun Giap
collection USM
description In twenty-first century, it has been witness the tremendous growth of technology in biomedical recording application particularly electrocardiogram (ECG) recording system and has had a profound impact on our daily life. The conventional ECG monitoring systems that are too bulky in nature which restrict the acquisition time has led to the design of low power battery operated portable ECG device. It helps to ensure good portability and enhanced mobility, freeing the patient from entanglement of wires which conceives annoyance and discomfort. In addition, the low frequency flicker noise (1/f) has been the biggest hindrance for reliable ECG monitoring application device since ECG signals have the characteristics of low amplitude and low frequency. Therefore, the goals of this work are to design a low power front end differential instrumentation amplifier for ECG monitoring device and to achieve low input referred noise of the amplifier specifically low frequency flicker noise. The circuit is based on the chopper technique which is implemented together with self-biased folded cascode structure that has significant lower power consumption than the predecessor’s approaches while keeping the performance unchanged. A self-biased scheme that saves power and reduces circuit area is chosen to eliminate the needs of external biasing circuitry by generating bias voltages from internal nodes of the circuit. It is developed through a series of iterative adjustments of component values and transistor sizes. For the case of chopper implementation, the usedmodulation technique converts the low frequency range of the input signals to a higher frequency range far above the dominant flicker noise. The second chopping module that acts as a demodulator brings the desired output back to the baseband and shifts the noise to the high chopping frequency. The modulated noise and the unwanted chopping spikes are then removed by a low frequency band pass filter. By the same token, folded cascode amplifier has benefit in low noise since smaller device size results in a better signal to noise ratio as the absolute area of the design contribute noises. The circuit is designed using SILTERRA 0.18 μm CMOS technology process with VIRTUOSO CADENCE. The pre-layout simulated results of the amplifier show ultra-low power of 1.926 μW and low noise of 415 nV/√Hz at 10 Hz which outperforms the renowned architectures of biomedical amplifier. Moreover, high differential voltage gain of 54.32 dB and 102.82 dB in CMRR are achieved.
first_indexed 2024-03-06T15:34:25Z
format Thesis
id usm.eprints-45778
institution Universiti Sains Malaysia
language English
last_indexed 2024-03-06T15:34:25Z
publishDate 2015
record_format dspace
spelling usm.eprints-457782020-10-22T03:03:20Z http://eprints.usm.my/45778/ Self-Biased Folded Cascode Instrumentation Amplifier Using Chopper Technique For Ecg Lau, Jun Giap T Technology TK1-9971 Electrical engineering. Electronics. Nuclear engineering In twenty-first century, it has been witness the tremendous growth of technology in biomedical recording application particularly electrocardiogram (ECG) recording system and has had a profound impact on our daily life. The conventional ECG monitoring systems that are too bulky in nature which restrict the acquisition time has led to the design of low power battery operated portable ECG device. It helps to ensure good portability and enhanced mobility, freeing the patient from entanglement of wires which conceives annoyance and discomfort. In addition, the low frequency flicker noise (1/f) has been the biggest hindrance for reliable ECG monitoring application device since ECG signals have the characteristics of low amplitude and low frequency. Therefore, the goals of this work are to design a low power front end differential instrumentation amplifier for ECG monitoring device and to achieve low input referred noise of the amplifier specifically low frequency flicker noise. The circuit is based on the chopper technique which is implemented together with self-biased folded cascode structure that has significant lower power consumption than the predecessor’s approaches while keeping the performance unchanged. A self-biased scheme that saves power and reduces circuit area is chosen to eliminate the needs of external biasing circuitry by generating bias voltages from internal nodes of the circuit. It is developed through a series of iterative adjustments of component values and transistor sizes. For the case of chopper implementation, the usedmodulation technique converts the low frequency range of the input signals to a higher frequency range far above the dominant flicker noise. The second chopping module that acts as a demodulator brings the desired output back to the baseband and shifts the noise to the high chopping frequency. The modulated noise and the unwanted chopping spikes are then removed by a low frequency band pass filter. By the same token, folded cascode amplifier has benefit in low noise since smaller device size results in a better signal to noise ratio as the absolute area of the design contribute noises. The circuit is designed using SILTERRA 0.18 μm CMOS technology process with VIRTUOSO CADENCE. The pre-layout simulated results of the amplifier show ultra-low power of 1.926 μW and low noise of 415 nV/√Hz at 10 Hz which outperforms the renowned architectures of biomedical amplifier. Moreover, high differential voltage gain of 54.32 dB and 102.82 dB in CMRR are achieved. 2015-09 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/45778/1/Self-Biased%20Folded%20Cascode%20Instrumentation%20Amplifier%20Using%20Chopper%20Technique%20For%20Ecg.pdf Lau, Jun Giap (2015) Self-Biased Folded Cascode Instrumentation Amplifier Using Chopper Technique For Ecg. Masters thesis, Universiti Sains Malaysia.
spellingShingle T Technology
TK1-9971 Electrical engineering. Electronics. Nuclear engineering
Lau, Jun Giap
Self-Biased Folded Cascode Instrumentation Amplifier Using Chopper Technique For Ecg
title Self-Biased Folded Cascode Instrumentation Amplifier Using Chopper Technique For Ecg
title_full Self-Biased Folded Cascode Instrumentation Amplifier Using Chopper Technique For Ecg
title_fullStr Self-Biased Folded Cascode Instrumentation Amplifier Using Chopper Technique For Ecg
title_full_unstemmed Self-Biased Folded Cascode Instrumentation Amplifier Using Chopper Technique For Ecg
title_short Self-Biased Folded Cascode Instrumentation Amplifier Using Chopper Technique For Ecg
title_sort self biased folded cascode instrumentation amplifier using chopper technique for ecg
topic T Technology
TK1-9971 Electrical engineering. Electronics. Nuclear engineering
url http://eprints.usm.my/45778/1/Self-Biased%20Folded%20Cascode%20Instrumentation%20Amplifier%20Using%20Chopper%20Technique%20For%20Ecg.pdf
work_keys_str_mv AT laujungiap selfbiasedfoldedcascodeinstrumentationamplifierusingchoppertechniqueforecg