Study of output factors of electron beam based on the simple model

The output factors for clinical electron beams have been shown to be dependant on beam energy, field size and collimator design. The purpose of this study was to investigate the application of the equation of the output factors for a rectangular field size, which developed from Gaussian scatter m...

Full description

Bibliographic Details
Main Author: Sohaimi, Norhanna
Format: Thesis
Language:English
Published: 2004
Subjects:
Online Access:http://eprints.usm.my/46331/1/LI...Norhanna%20Binti%20Sohaimi...2004...-24%20pages.pdf
_version_ 1825905540408016896
author Sohaimi, Norhanna
author_facet Sohaimi, Norhanna
author_sort Sohaimi, Norhanna
collection USM
description The output factors for clinical electron beams have been shown to be dependant on beam energy, field size and collimator design. The purpose of this study was to investigate the application of the equation of the output factors for a rectangular field size, which developed from Gaussian scatter model for electron beams used in Radiotherapy Department, Universiti Sains Malaysia Hospital. The output factors were measured for 5 MeV and 10 MeV electron beams for various applicators and square or rectangular insert combinations used in clinical services. The field sizes ranged from 3 em x 3 em to 25 em x 25 em at source to surface distance of 1 00 em. The parallel plate ionization chamber was used to collect the charge and was placed at dmax inside the solid water material for each electron beam energies. Calculated output factors for the fields studied agreed with the measured output factors within ±2o/o. This demonstrated that for this Linear Accelerator {MXE; LINAC MEVATRON), the output factors calculated in homogenous solid water phantom could be predicted accurately using theoretical formula.
first_indexed 2024-03-06T15:35:59Z
format Thesis
id usm.eprints-46331
institution Universiti Sains Malaysia
language English
last_indexed 2024-03-06T15:35:59Z
publishDate 2004
record_format dspace
spelling usm.eprints-463312020-02-26T01:20:40Z http://eprints.usm.my/46331/ Study of output factors of electron beam based on the simple model Sohaimi, Norhanna RA Public aspects of medicine The output factors for clinical electron beams have been shown to be dependant on beam energy, field size and collimator design. The purpose of this study was to investigate the application of the equation of the output factors for a rectangular field size, which developed from Gaussian scatter model for electron beams used in Radiotherapy Department, Universiti Sains Malaysia Hospital. The output factors were measured for 5 MeV and 10 MeV electron beams for various applicators and square or rectangular insert combinations used in clinical services. The field sizes ranged from 3 em x 3 em to 25 em x 25 em at source to surface distance of 1 00 em. The parallel plate ionization chamber was used to collect the charge and was placed at dmax inside the solid water material for each electron beam energies. Calculated output factors for the fields studied agreed with the measured output factors within ±2o/o. This demonstrated that for this Linear Accelerator {MXE; LINAC MEVATRON), the output factors calculated in homogenous solid water phantom could be predicted accurately using theoretical formula. 2004 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/46331/1/LI...Norhanna%20Binti%20Sohaimi...2004...-24%20pages.pdf Sohaimi, Norhanna (2004) Study of output factors of electron beam based on the simple model. Masters thesis, Universiti Sains Malaysia.
spellingShingle RA Public aspects of medicine
Sohaimi, Norhanna
Study of output factors of electron beam based on the simple model
title Study of output factors of electron beam based on the simple model
title_full Study of output factors of electron beam based on the simple model
title_fullStr Study of output factors of electron beam based on the simple model
title_full_unstemmed Study of output factors of electron beam based on the simple model
title_short Study of output factors of electron beam based on the simple model
title_sort study of output factors of electron beam based on the simple model
topic RA Public aspects of medicine
url http://eprints.usm.my/46331/1/LI...Norhanna%20Binti%20Sohaimi...2004...-24%20pages.pdf
work_keys_str_mv AT sohaiminorhanna studyofoutputfactorsofelectronbeambasedonthesimplemodel