Evaluation Of Virtual Bolus For Tomotherapy Dose Optimization In Superficial Cancers

This study evaluates the radiation dosimetry effects of using virtual-bolus (VB) in TomoTherapy Treatment Planning System (TPS) for Planning-Target-Volume (PTV) that extends to skin or body-surface. PTV was contoured on phantom that extended to the phantom surface. Virtual bolus of various thickness...

Full description

Bibliographic Details
Main Author: Ooi, Gim Chee
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:http://eprints.usm.my/51679/1/OOI%20GIM%20CHEE%20-%20TESIS%20cut.pdf
_version_ 1797012666259079168
author Ooi, Gim Chee
author_facet Ooi, Gim Chee
author_sort Ooi, Gim Chee
collection USM
description This study evaluates the radiation dosimetry effects of using virtual-bolus (VB) in TomoTherapy Treatment Planning System (TPS) for Planning-Target-Volume (PTV) that extends to skin or body-surface. PTV was contoured on phantom that extended to the phantom surface. Virtual bolus of various thickness (0.2 cm / 0.4 cm / 0.6 cm) and densities (0.5 g/cm3 or 1.0 g/cm3) combinations were drawn to provide “virtual” build-up region for the TPS and then optimized with TomoTherapy TPS. EBT3 Gafchromic Film was calibrated and used to analyze the dose profiles across PTV and the phantom surface, and gamma analysis was peformed for the photon fluence with Distance-to-Agreement (DTA) 3 mm and Dose Difference 3% criteria. TomoTherapy Planned-Adaptive software was used to analyze the delivered Dose-Volume-Histograms (DVHs) reconstructed from the mega-voltage computed tomography (MVCT) acquisition. Without VB used, the control set optimization showed maximum dose close to 110% at the phantom edge or the surface due to lack of build-up region. VB of 0.2 cm was shown to be unable to provide adequate build-up area. The use of VBs of 0.4 cm and 0.6 cm for dose optimization were able to control the maximum dose in the TPS and also in the actual radiation delivery. However, VB of 0.6 cm exhibited large reduction in dose coverage (95%) in the actual radiation delivery.
first_indexed 2024-03-06T15:51:04Z
format Thesis
id usm.eprints-51679
institution Universiti Sains Malaysia
language English
last_indexed 2024-03-06T15:51:04Z
publishDate 2020
record_format dspace
spelling usm.eprints-516792022-02-27T05:04:31Z http://eprints.usm.my/51679/ Evaluation Of Virtual Bolus For Tomotherapy Dose Optimization In Superficial Cancers Ooi, Gim Chee QC1 Physics (General) This study evaluates the radiation dosimetry effects of using virtual-bolus (VB) in TomoTherapy Treatment Planning System (TPS) for Planning-Target-Volume (PTV) that extends to skin or body-surface. PTV was contoured on phantom that extended to the phantom surface. Virtual bolus of various thickness (0.2 cm / 0.4 cm / 0.6 cm) and densities (0.5 g/cm3 or 1.0 g/cm3) combinations were drawn to provide “virtual” build-up region for the TPS and then optimized with TomoTherapy TPS. EBT3 Gafchromic Film was calibrated and used to analyze the dose profiles across PTV and the phantom surface, and gamma analysis was peformed for the photon fluence with Distance-to-Agreement (DTA) 3 mm and Dose Difference 3% criteria. TomoTherapy Planned-Adaptive software was used to analyze the delivered Dose-Volume-Histograms (DVHs) reconstructed from the mega-voltage computed tomography (MVCT) acquisition. Without VB used, the control set optimization showed maximum dose close to 110% at the phantom edge or the surface due to lack of build-up region. VB of 0.2 cm was shown to be unable to provide adequate build-up area. The use of VBs of 0.4 cm and 0.6 cm for dose optimization were able to control the maximum dose in the TPS and also in the actual radiation delivery. However, VB of 0.6 cm exhibited large reduction in dose coverage (95%) in the actual radiation delivery. 2020-06 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/51679/1/OOI%20GIM%20CHEE%20-%20TESIS%20cut.pdf Ooi, Gim Chee (2020) Evaluation Of Virtual Bolus For Tomotherapy Dose Optimization In Superficial Cancers. Masters thesis, Universiti Sains Malaysia.
spellingShingle QC1 Physics (General)
Ooi, Gim Chee
Evaluation Of Virtual Bolus For Tomotherapy Dose Optimization In Superficial Cancers
title Evaluation Of Virtual Bolus For Tomotherapy Dose Optimization In Superficial Cancers
title_full Evaluation Of Virtual Bolus For Tomotherapy Dose Optimization In Superficial Cancers
title_fullStr Evaluation Of Virtual Bolus For Tomotherapy Dose Optimization In Superficial Cancers
title_full_unstemmed Evaluation Of Virtual Bolus For Tomotherapy Dose Optimization In Superficial Cancers
title_short Evaluation Of Virtual Bolus For Tomotherapy Dose Optimization In Superficial Cancers
title_sort evaluation of virtual bolus for tomotherapy dose optimization in superficial cancers
topic QC1 Physics (General)
url http://eprints.usm.my/51679/1/OOI%20GIM%20CHEE%20-%20TESIS%20cut.pdf
work_keys_str_mv AT ooigimchee evaluationofvirtualbolusfortomotherapydoseoptimizationinsuperficialcancers