In Malaysia, almost all houses in rural area are non-engineered structures. The roof of these houses is susceptible to failure and many types if roofing failure can be expected. This study examines the pull-out capacity of several simple connections meant for tying the timber purlin to rafter. The t...

Full description

Bibliographic Details
Main Author: Humayunkabir, Sheikh Hazwan
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2017
Subjects:
Online Access:http://eprints.usm.my/52119/1/Experimental%20Investigation%20On%20The%20Load%20Carrying%20Capacity%20Of%20Modified%20Purlin%20To%20Rafter%20Connection_Sheikh%20Hazwan%20Humayunkabir_A9_2017.pdf
_version_ 1825906622165155840
author Humayunkabir, Sheikh Hazwan
author_facet Humayunkabir, Sheikh Hazwan
author_sort Humayunkabir, Sheikh Hazwan
collection USM
description In Malaysia, almost all houses in rural area are non-engineered structures. The roof of these houses is susceptible to failure and many types if roofing failure can be expected. This study examines the pull-out capacity of several simple connections meant for tying the timber purlin to rafter. The types of connections are single nail, double nail, nail plus metal strap and nail plus rope. The tests were conducted on timber type Damar Minyak and Dark Red Meranti, both are classified under strength group 5 and 6. The wind load was applied in the form of pull-out force generated via in-house frame and Universal Testing Machine. The results showed that, for single nail connection, two phases of response were observed. Other types of connections showed three distinct phases from beginning until failure. This phenomenon is particularly true for both types of timber. In the case of timber type Damar Minyak, the maximum pull-out capacity exhibited by the nail and metal strap connection (1.55 kN) followed by nail and rope (1.485 kN), double nail (0.825 kN) and single nail (0.445 kN). However, for timber type Dark Red Meranti, the use of double nail spaced at 30 mm apart exhibited the highest pull-out capacity (2.5 kN) followed by nail and metal strap (1.8 kN), nail and rope (1.53 kN) and single nail (1.22 kN). It was also noted that stronger timber grade developed higher nail to timber connection compared to lower timber grade. The most efficient connection for timber type Damar Minyak and Dark Red Meranti was found to be nail plus rope and double nail, respectively.
first_indexed 2024-03-06T15:52:18Z
format Monograph
id usm.eprints-52119
institution Universiti Sains Malaysia
language English
last_indexed 2024-03-06T15:52:18Z
publishDate 2017
publisher Universiti Sains Malaysia
record_format dspace
spelling usm.eprints-521192022-03-31T04:40:30Z http://eprints.usm.my/52119/ Experimental Investigation On The Load Carrying Capacity Of Modified Purlin To Rafter Connection Humayunkabir, Sheikh Hazwan T Technology TA Engineering (General). Civil engineering (General) In Malaysia, almost all houses in rural area are non-engineered structures. The roof of these houses is susceptible to failure and many types if roofing failure can be expected. This study examines the pull-out capacity of several simple connections meant for tying the timber purlin to rafter. The types of connections are single nail, double nail, nail plus metal strap and nail plus rope. The tests were conducted on timber type Damar Minyak and Dark Red Meranti, both are classified under strength group 5 and 6. The wind load was applied in the form of pull-out force generated via in-house frame and Universal Testing Machine. The results showed that, for single nail connection, two phases of response were observed. Other types of connections showed three distinct phases from beginning until failure. This phenomenon is particularly true for both types of timber. In the case of timber type Damar Minyak, the maximum pull-out capacity exhibited by the nail and metal strap connection (1.55 kN) followed by nail and rope (1.485 kN), double nail (0.825 kN) and single nail (0.445 kN). However, for timber type Dark Red Meranti, the use of double nail spaced at 30 mm apart exhibited the highest pull-out capacity (2.5 kN) followed by nail and metal strap (1.8 kN), nail and rope (1.53 kN) and single nail (1.22 kN). It was also noted that stronger timber grade developed higher nail to timber connection compared to lower timber grade. The most efficient connection for timber type Damar Minyak and Dark Red Meranti was found to be nail plus rope and double nail, respectively. Universiti Sains Malaysia 2017-06-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/52119/1/Experimental%20Investigation%20On%20The%20Load%20Carrying%20Capacity%20Of%20Modified%20Purlin%20To%20Rafter%20Connection_Sheikh%20Hazwan%20Humayunkabir_A9_2017.pdf Humayunkabir, Sheikh Hazwan (2017) Experimental Investigation On The Load Carrying Capacity Of Modified Purlin To Rafter Connection. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Awam. (Submitted)
spellingShingle T Technology
TA Engineering (General). Civil engineering (General)
Humayunkabir, Sheikh Hazwan
Experimental Investigation On The Load Carrying Capacity Of Modified Purlin To Rafter Connection
title Experimental Investigation On The Load Carrying Capacity Of Modified Purlin To Rafter Connection
title_full Experimental Investigation On The Load Carrying Capacity Of Modified Purlin To Rafter Connection
title_fullStr Experimental Investigation On The Load Carrying Capacity Of Modified Purlin To Rafter Connection
title_full_unstemmed Experimental Investigation On The Load Carrying Capacity Of Modified Purlin To Rafter Connection
title_short Experimental Investigation On The Load Carrying Capacity Of Modified Purlin To Rafter Connection
title_sort experimental investigation on the load carrying capacity of modified purlin to rafter connection
topic T Technology
TA Engineering (General). Civil engineering (General)
url http://eprints.usm.my/52119/1/Experimental%20Investigation%20On%20The%20Load%20Carrying%20Capacity%20Of%20Modified%20Purlin%20To%20Rafter%20Connection_Sheikh%20Hazwan%20Humayunkabir_A9_2017.pdf
work_keys_str_mv AT humayunkabirsheikhhazwan experimentalinvestigationontheloadcarryingcapacityofmodifiedpurlintorafterconnection