Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination
There are two types of tomography systems, medical tomography and process tomography. ECT is one of the branches of process tomography. ECT or Electrical Capacitance Tomography is one of the techniques to measure the internal spatial distribution of materials. This new and very detailed knowle...
Main Author: | |
---|---|
Format: | Monograph |
Language: | English |
Published: |
Universiti Sains Malaysia
2005
|
Subjects: | |
Online Access: | http://eprints.usm.my/57793/1/Optimum%20Electrical%20Capacitance%20Tomography%20Sensor%20For%20Oil-Height%20Determination_Muhamed%20Sufian%20Hamzah.pdf |
_version_ | 1825907765572272128 |
---|---|
author | Hamzah, Muhamed Sufian |
author_facet | Hamzah, Muhamed Sufian |
author_sort | Hamzah, Muhamed Sufian |
collection | USM |
description | There are two types of tomography systems, medical tomography and process
tomography. ECT is one of the branches of process tomography. ECT or Electrical
Capacitance Tomography is one of the techniques to measure the internal spatial
distribution of materials. This new and very detailed knowledge allows improved
design of process equipment. ECT process is based on the electromagnet properties of
components in the volume measurement. In this thesis, MATLAB is used to generate
raw ECT dataset with using an ECT simulator. The variable value of an ECT design
parameters affect the sensitivity of raw ECT dataset. In this project, the range of pipe
thickness, R2 is uses 1.02 to 1.38 units and the range of electrode angle, θ is 5' to 24'.
The mean of absolute error with comparison between oil height target and oil height
ANN measurement is plot in two graphs, mean absolute error versus parameter R2
and mean absolute error versus parameter θ. The graphs show the changes in oil
height estimation that occur when the ECT system parameters are changed. |
first_indexed | 2024-03-06T16:09:01Z |
format | Monograph |
id | usm.eprints-57793 |
institution | Universiti Sains Malaysia |
language | English |
last_indexed | 2024-03-06T16:09:01Z |
publishDate | 2005 |
publisher | Universiti Sains Malaysia |
record_format | dspace |
spelling | usm.eprints-577932023-04-04T09:30:50Z http://eprints.usm.my/57793/ Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination Hamzah, Muhamed Sufian T Technology TK Electrical Engineering. Electronics. Nuclear Engineering There are two types of tomography systems, medical tomography and process tomography. ECT is one of the branches of process tomography. ECT or Electrical Capacitance Tomography is one of the techniques to measure the internal spatial distribution of materials. This new and very detailed knowledge allows improved design of process equipment. ECT process is based on the electromagnet properties of components in the volume measurement. In this thesis, MATLAB is used to generate raw ECT dataset with using an ECT simulator. The variable value of an ECT design parameters affect the sensitivity of raw ECT dataset. In this project, the range of pipe thickness, R2 is uses 1.02 to 1.38 units and the range of electrode angle, θ is 5' to 24'. The mean of absolute error with comparison between oil height target and oil height ANN measurement is plot in two graphs, mean absolute error versus parameter R2 and mean absolute error versus parameter θ. The graphs show the changes in oil height estimation that occur when the ECT system parameters are changed. Universiti Sains Malaysia 2005-03-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/57793/1/Optimum%20Electrical%20Capacitance%20Tomography%20Sensor%20For%20Oil-Height%20Determination_Muhamed%20Sufian%20Hamzah.pdf Hamzah, Muhamed Sufian (2005) Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Elektrik dan Elektronik. (Submitted) |
spellingShingle | T Technology TK Electrical Engineering. Electronics. Nuclear Engineering Hamzah, Muhamed Sufian Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination |
title | Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination |
title_full | Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination |
title_fullStr | Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination |
title_full_unstemmed | Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination |
title_short | Optimum Electrical Capacitance Tomography Sensor For Oil-Height Determination |
title_sort | optimum electrical capacitance tomography sensor for oil height determination |
topic | T Technology TK Electrical Engineering. Electronics. Nuclear Engineering |
url | http://eprints.usm.my/57793/1/Optimum%20Electrical%20Capacitance%20Tomography%20Sensor%20For%20Oil-Height%20Determination_Muhamed%20Sufian%20Hamzah.pdf |
work_keys_str_mv | AT hamzahmuhamedsufian optimumelectricalcapacitancetomographysensorforoilheightdetermination |