Thermal Comfort & Its Relation To Ventilation Approaches In The Main Prayer Hall Of Mosque & Hostel Room, USM Engineering Campus

This study was conducted to determine users' satisfaction with the building's indoor environment. This study was performed at the main prayer hall of Pusat Islam Engineering Campus, USM and the hostel room in Desasiswa Lembaran (SH2). It involved determining whether the thermal comfort...

Full description

Bibliographic Details
Main Author: Husain, Sharmira
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2022
Subjects:
Online Access:http://eprints.usm.my/58190/1/Thermal%20Comfort%20%26%20Its%20Relation%20To%20Ventilation%20Approaches%20In%20The%20Main%20Prayer%20Hall%20Of%20Mosque%20%26%20Hostel%20Room%2C%20USM%20Engineering%20Campus.pdf
_version_ 1825907848734834688
author Husain, Sharmira
author_facet Husain, Sharmira
author_sort Husain, Sharmira
collection USM
description This study was conducted to determine users' satisfaction with the building's indoor environment. This study was performed at the main prayer hall of Pusat Islam Engineering Campus, USM and the hostel room in Desasiswa Lembaran (SH2). It involved determining whether the thermal comfort standards were being met, which included the air temperature and relative humidity. The data were measured using Temperature- Relative Humidity (T-Rh) Data Logger, and the result was downloaded using T-Rh software. The Center for the Built Environment (CBE) Thermal Comfort Tool is then used to input the parameters to calculate the Predicted Mean Value (PMV) and Predicted Percentage Dissatisfied (PPD) for ASHRAE Standard-55. The parameters inserted are air temperature, relative humidity, air velocity, metabolic rate and clothing level. The PPD value shows the percentage of dissatisfaction. The PMV and PPD value results were compared with the Industry Code of Practice (ICOP) 2010 standard limit. The monitoring for this study was conducted for two sessions on a day, 1 P.M – 2 P.M. and 5 P.M. -6 P.M. for both locations with minute intervals. The highest temperature recorded in the mosque is 33.7°C, monitoring at 1 P.M -2 P.M. (Day 1). For monitoring in the hostel room, the highest PMV and PPD values obtained were 1.6 and 57%, respectively. Overall, the results indicate that most thermal comfort parameters measured do not comply with the ICOP standard limit, whereby the PMV is not within the range of -0.5 <PMV< +0.5 and PPD is >10%. This is due to poor façade design and inadequate building ventilation systems.
first_indexed 2024-03-06T16:10:12Z
format Monograph
id usm.eprints-58190
institution Universiti Sains Malaysia
language English
last_indexed 2024-03-06T16:10:12Z
publishDate 2022
publisher Universiti Sains Malaysia
record_format dspace
spelling usm.eprints-581902023-04-25T07:49:42Z http://eprints.usm.my/58190/ Thermal Comfort & Its Relation To Ventilation Approaches In The Main Prayer Hall Of Mosque & Hostel Room, USM Engineering Campus Husain, Sharmira T Technology TA Engineering (General). Civil engineering (General) This study was conducted to determine users' satisfaction with the building's indoor environment. This study was performed at the main prayer hall of Pusat Islam Engineering Campus, USM and the hostel room in Desasiswa Lembaran (SH2). It involved determining whether the thermal comfort standards were being met, which included the air temperature and relative humidity. The data were measured using Temperature- Relative Humidity (T-Rh) Data Logger, and the result was downloaded using T-Rh software. The Center for the Built Environment (CBE) Thermal Comfort Tool is then used to input the parameters to calculate the Predicted Mean Value (PMV) and Predicted Percentage Dissatisfied (PPD) for ASHRAE Standard-55. The parameters inserted are air temperature, relative humidity, air velocity, metabolic rate and clothing level. The PPD value shows the percentage of dissatisfaction. The PMV and PPD value results were compared with the Industry Code of Practice (ICOP) 2010 standard limit. The monitoring for this study was conducted for two sessions on a day, 1 P.M – 2 P.M. and 5 P.M. -6 P.M. for both locations with minute intervals. The highest temperature recorded in the mosque is 33.7°C, monitoring at 1 P.M -2 P.M. (Day 1). For monitoring in the hostel room, the highest PMV and PPD values obtained were 1.6 and 57%, respectively. Overall, the results indicate that most thermal comfort parameters measured do not comply with the ICOP standard limit, whereby the PMV is not within the range of -0.5 <PMV< +0.5 and PPD is >10%. This is due to poor façade design and inadequate building ventilation systems. Universiti Sains Malaysia 2022-07-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/58190/1/Thermal%20Comfort%20%26%20Its%20Relation%20To%20Ventilation%20Approaches%20In%20The%20Main%20Prayer%20Hall%20Of%20Mosque%20%26%20Hostel%20Room%2C%20USM%20Engineering%20Campus.pdf Husain, Sharmira (2022) Thermal Comfort & Its Relation To Ventilation Approaches In The Main Prayer Hall Of Mosque & Hostel Room, USM Engineering Campus. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Awam. (Submitted)
spellingShingle T Technology
TA Engineering (General). Civil engineering (General)
Husain, Sharmira
Thermal Comfort & Its Relation To Ventilation Approaches In The Main Prayer Hall Of Mosque & Hostel Room, USM Engineering Campus
title Thermal Comfort & Its Relation To Ventilation Approaches In The Main Prayer Hall Of Mosque & Hostel Room, USM Engineering Campus
title_full Thermal Comfort & Its Relation To Ventilation Approaches In The Main Prayer Hall Of Mosque & Hostel Room, USM Engineering Campus
title_fullStr Thermal Comfort & Its Relation To Ventilation Approaches In The Main Prayer Hall Of Mosque & Hostel Room, USM Engineering Campus
title_full_unstemmed Thermal Comfort & Its Relation To Ventilation Approaches In The Main Prayer Hall Of Mosque & Hostel Room, USM Engineering Campus
title_short Thermal Comfort & Its Relation To Ventilation Approaches In The Main Prayer Hall Of Mosque & Hostel Room, USM Engineering Campus
title_sort thermal comfort its relation to ventilation approaches in the main prayer hall of mosque hostel room usm engineering campus
topic T Technology
TA Engineering (General). Civil engineering (General)
url http://eprints.usm.my/58190/1/Thermal%20Comfort%20%26%20Its%20Relation%20To%20Ventilation%20Approaches%20In%20The%20Main%20Prayer%20Hall%20Of%20Mosque%20%26%20Hostel%20Room%2C%20USM%20Engineering%20Campus.pdf
work_keys_str_mv AT husainsharmira thermalcomfortitsrelationtoventilationapproachesinthemainprayerhallofmosquehostelroomusmengineeringcampus