Simultaneous determination of methanol and ethanol in local and foreign alcoholic drinks by GC-FID

Intoxication with methanol resulting from the consumption of alcoholic beverages is a worldwide issue that is growing. Methanol can cause severe health issues and lead to fatality. Due to these reasons, numerous methods for measuring methanol concentrations in alcoholic beverages had been developed....

Full description

Bibliographic Details
Main Author: Kalid, Manja Murni Che
Format: Thesis
Language:English
Published: 2022
Subjects:
Online Access:http://eprints.usm.my/58462/1/MANJA%20MURNI%20CHE%20KALID-24%20pages.pdf
_version_ 1797014074460995584
author Kalid, Manja Murni Che
author_facet Kalid, Manja Murni Che
author_sort Kalid, Manja Murni Che
collection USM
description Intoxication with methanol resulting from the consumption of alcoholic beverages is a worldwide issue that is growing. Methanol can cause severe health issues and lead to fatality. Due to these reasons, numerous methods for measuring methanol concentrations in alcoholic beverages had been developed. The aim of this study was to develop an accurate, sensitive and simple method by using GC-FID for simultaneous determination of methanol and ethanol in local and foreign brands of alcoholic beverages. The method was developed by optimisation of the GC parameters. Optimised parameters included an initial oven temperature of 40°C held for 2 minutes, ramping at 25 °C/min until an oven temperature of 100°C was reached, a carrier gas flow rate of 4.5 mL/min, a split ratio of 2:1 with injection volume of 10 μL. The optimised method was validated in accordance with UNODC guidelines in terms of specificity, linearity, detection and quantification limits, precision and accuracy. Both methanol and ethanol calibration curves offered good linearity, with r2 > 0.99 throughout ranges of 0.001-0.625% for methanol and 5-25% for ethanol. The respective LOQs for methanol and ethanol were 1.72 mg/L and 1.76 mg/L with good precision and recoveries. This method required 5.40 minutes to yield results. This established method was then applied by analysing 19 different alcoholic beverages by injecting them directly into the GC-FID after acetonitrile was added as an internal standard. This study revealed that 36.8% of the samples examined contained methanol concentrations ranging from 0-0.0198%, whereas ethanol was present in every sample. The proposed method was sensitive, straightforward, and did not require any pre-treatment, making it suitable for routine toxicological forensic sample analysis. Importantly, trace amounts of methanol were reliably detected without interference from significantly higher concentrations of ethanol. In conclusion, this research had demonstrated that the DB ALC 1 column capillary in GC-FID with optimised parameters is very selective and highly sensitive in the simultaneous detection and measurement of methanol and ethanol in alcoholic beverages.
first_indexed 2024-03-06T16:11:01Z
format Thesis
id usm.eprints-58462
institution Universiti Sains Malaysia
language English
last_indexed 2024-03-06T16:11:01Z
publishDate 2022
record_format dspace
spelling usm.eprints-584622023-05-15T04:12:59Z http://eprints.usm.my/58462/ Simultaneous determination of methanol and ethanol in local and foreign alcoholic drinks by GC-FID Kalid, Manja Murni Che TP315-360 Fuel Intoxication with methanol resulting from the consumption of alcoholic beverages is a worldwide issue that is growing. Methanol can cause severe health issues and lead to fatality. Due to these reasons, numerous methods for measuring methanol concentrations in alcoholic beverages had been developed. The aim of this study was to develop an accurate, sensitive and simple method by using GC-FID for simultaneous determination of methanol and ethanol in local and foreign brands of alcoholic beverages. The method was developed by optimisation of the GC parameters. Optimised parameters included an initial oven temperature of 40°C held for 2 minutes, ramping at 25 °C/min until an oven temperature of 100°C was reached, a carrier gas flow rate of 4.5 mL/min, a split ratio of 2:1 with injection volume of 10 μL. The optimised method was validated in accordance with UNODC guidelines in terms of specificity, linearity, detection and quantification limits, precision and accuracy. Both methanol and ethanol calibration curves offered good linearity, with r2 > 0.99 throughout ranges of 0.001-0.625% for methanol and 5-25% for ethanol. The respective LOQs for methanol and ethanol were 1.72 mg/L and 1.76 mg/L with good precision and recoveries. This method required 5.40 minutes to yield results. This established method was then applied by analysing 19 different alcoholic beverages by injecting them directly into the GC-FID after acetonitrile was added as an internal standard. This study revealed that 36.8% of the samples examined contained methanol concentrations ranging from 0-0.0198%, whereas ethanol was present in every sample. The proposed method was sensitive, straightforward, and did not require any pre-treatment, making it suitable for routine toxicological forensic sample analysis. Importantly, trace amounts of methanol were reliably detected without interference from significantly higher concentrations of ethanol. In conclusion, this research had demonstrated that the DB ALC 1 column capillary in GC-FID with optimised parameters is very selective and highly sensitive in the simultaneous detection and measurement of methanol and ethanol in alcoholic beverages. 2022-09 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/58462/1/MANJA%20MURNI%20CHE%20KALID-24%20pages.pdf Kalid, Manja Murni Che (2022) Simultaneous determination of methanol and ethanol in local and foreign alcoholic drinks by GC-FID. Masters thesis, Universiti Sains Malaysia.
spellingShingle TP315-360 Fuel
Kalid, Manja Murni Che
Simultaneous determination of methanol and ethanol in local and foreign alcoholic drinks by GC-FID
title Simultaneous determination of methanol and ethanol in local and foreign alcoholic drinks by GC-FID
title_full Simultaneous determination of methanol and ethanol in local and foreign alcoholic drinks by GC-FID
title_fullStr Simultaneous determination of methanol and ethanol in local and foreign alcoholic drinks by GC-FID
title_full_unstemmed Simultaneous determination of methanol and ethanol in local and foreign alcoholic drinks by GC-FID
title_short Simultaneous determination of methanol and ethanol in local and foreign alcoholic drinks by GC-FID
title_sort simultaneous determination of methanol and ethanol in local and foreign alcoholic drinks by gc fid
topic TP315-360 Fuel
url http://eprints.usm.my/58462/1/MANJA%20MURNI%20CHE%20KALID-24%20pages.pdf
work_keys_str_mv AT kalidmanjamurniche simultaneousdeterminationofmethanolandethanolinlocalandforeignalcoholicdrinksbygcfid