Simulation Of Blood Flow Through Transcatheter Heart Valve (Thv) Using Ansys Fluid Structure Interaction
As transcatheter heart valve replacement (THVR) progressively became an alternative to surgical heart valve (SHV) from it first implantation in 2000, numerous research and lots of improvement has been made and still on going until now. However, does the effectiveness of the transcatheter heart valve...
Main Author: | |
---|---|
Format: | Monograph |
Language: | English |
Published: |
Universiti Sains Malaysia
2019
|
Subjects: | |
Online Access: | http://eprints.usm.my/58467/1/Simulation%20Of%20Blood%20Flow%20Through%20Transcatheter%20Heart%20Valve%20%28Thv%29%20Using%20Ansys%20Fluid%20Structure%20Interaction.pdf |
_version_ | 1825907903333138432 |
---|---|
author | Juma’at, Mohamad Haziq |
author_facet | Juma’at, Mohamad Haziq |
author_sort | Juma’at, Mohamad Haziq |
collection | USM |
description | As transcatheter heart valve replacement (THVR) progressively became an alternative to surgical heart valve (SHV) from it first implantation in 2000, numerous research and lots of improvement has been made and still on going until now. However, does the effectiveness of the transcatheter heart valve (THV) is on par with the mechanical heart valve and other prosthetic heart valves.
In this research project, the three-dimensional 29 mm SAPIEN XT inside the left side heart is designed and simulated using computational fluid dynamics software. The simulation is carried out by using ANSYS Fluid Structural Interaction (FSI) to analyse the fluid field, velocity, pressure, vortices and wall shear stress obtained. The simulation is validated by Particle Image Velocimetry (PIV) experiment by comparing the prosthetic mitral valve inlet velocity, outlet velocity and Doppler Velocity Index (DVI) of the THV. |
first_indexed | 2024-03-06T16:11:02Z |
format | Monograph |
id | usm.eprints-58467 |
institution | Universiti Sains Malaysia |
language | English |
last_indexed | 2024-03-06T16:11:02Z |
publishDate | 2019 |
publisher | Universiti Sains Malaysia |
record_format | dspace |
spelling | usm.eprints-584672023-05-11T07:48:10Z http://eprints.usm.my/58467/ Simulation Of Blood Flow Through Transcatheter Heart Valve (Thv) Using Ansys Fluid Structure Interaction Juma’at, Mohamad Haziq T Technology TJ Mechanical engineering and machinery As transcatheter heart valve replacement (THVR) progressively became an alternative to surgical heart valve (SHV) from it first implantation in 2000, numerous research and lots of improvement has been made and still on going until now. However, does the effectiveness of the transcatheter heart valve (THV) is on par with the mechanical heart valve and other prosthetic heart valves. In this research project, the three-dimensional 29 mm SAPIEN XT inside the left side heart is designed and simulated using computational fluid dynamics software. The simulation is carried out by using ANSYS Fluid Structural Interaction (FSI) to analyse the fluid field, velocity, pressure, vortices and wall shear stress obtained. The simulation is validated by Particle Image Velocimetry (PIV) experiment by comparing the prosthetic mitral valve inlet velocity, outlet velocity and Doppler Velocity Index (DVI) of the THV. Universiti Sains Malaysia 2019-05-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/58467/1/Simulation%20Of%20Blood%20Flow%20Through%20Transcatheter%20Heart%20Valve%20%28Thv%29%20Using%20Ansys%20Fluid%20Structure%20Interaction.pdf Juma’at, Mohamad Haziq (2019) Simulation Of Blood Flow Through Transcatheter Heart Valve (Thv) Using Ansys Fluid Structure Interaction. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Mekanik. (Submitted) |
spellingShingle | T Technology TJ Mechanical engineering and machinery Juma’at, Mohamad Haziq Simulation Of Blood Flow Through Transcatheter Heart Valve (Thv) Using Ansys Fluid Structure Interaction |
title | Simulation Of Blood Flow Through Transcatheter Heart Valve (Thv) Using Ansys Fluid Structure Interaction |
title_full | Simulation Of Blood Flow Through Transcatheter Heart Valve (Thv) Using Ansys Fluid Structure Interaction |
title_fullStr | Simulation Of Blood Flow Through Transcatheter Heart Valve (Thv) Using Ansys Fluid Structure Interaction |
title_full_unstemmed | Simulation Of Blood Flow Through Transcatheter Heart Valve (Thv) Using Ansys Fluid Structure Interaction |
title_short | Simulation Of Blood Flow Through Transcatheter Heart Valve (Thv) Using Ansys Fluid Structure Interaction |
title_sort | simulation of blood flow through transcatheter heart valve thv using ansys fluid structure interaction |
topic | T Technology TJ Mechanical engineering and machinery |
url | http://eprints.usm.my/58467/1/Simulation%20Of%20Blood%20Flow%20Through%20Transcatheter%20Heart%20Valve%20%28Thv%29%20Using%20Ansys%20Fluid%20Structure%20Interaction.pdf |
work_keys_str_mv | AT jumaatmohamadhaziq simulationofbloodflowthroughtranscatheterheartvalvethvusingansysfluidstructureinteraction |