Dosimetric verification of monaco treatment planning system (TPS) in heterogeneous medium for 6 mv linac

The Monaco TPS, employing the Monte Carlo dose calculation algorithm, offers high precision in radiotherapy planning. Accurate dose calculation in heterogeneous tissues necessitates comprehensive commissioning and verification due to its impact on patient outcomes. This study evaluates the dose calc...

Full description

Bibliographic Details
Main Author: Azlan, Adriana Batrisyia Noor Mohd
Format: Thesis
Language:English
Published: 2024
Subjects:
Online Access:http://eprints.usm.my/61084/1/Adriana%20Batrisyia%20Noor%20Mohd%20Azlan-E.pdf
_version_ 1817928311391649792
author Azlan, Adriana Batrisyia Noor Mohd
author_facet Azlan, Adriana Batrisyia Noor Mohd
author_sort Azlan, Adriana Batrisyia Noor Mohd
collection USM
description The Monaco TPS, employing the Monte Carlo dose calculation algorithm, offers high precision in radiotherapy planning. Accurate dose calculation in heterogeneous tissues necessitates comprehensive commissioning and verification due to its impact on patient outcomes. This study evaluates the dose calculation accuracy of Monaco TPS using Rando phantoms, thermoluminescence dosimeters (TLD-100) dosimeters, EBT3 Gafchromic films, and clinical patient data through patient-specific quality assurance (PSQA). Methods : Dosimetric verification of Monaco TPS was conducted on a head and neck Rando phantom for 3D conformal radiotherapy (3DCRT) whole brain radiotherapy (WBRT) and volumetric modulated arc therapy (VMAT) meningioma planning in heterogeneous environments, using 12 TLD-100s and EBT3 Gafchromic films. Additionally, six Eclipse TPS patient plans were replicated on Monaco TPS, and PSQA was performed using gamma criteria of 3% dose difference (DD) and 3 mm distance-to-agreement (DTA). Results :Monaco TPS demonstrated consistent percentage deviations within ±10% (ranging from 1.8% to 9.1%) between TPS calculated and TLD-measured doses for 3DCRT, with no significant difference (p > 0.05). EBT3 Gafchromic film dosimetry showed good agreement with TPS dose distributions, achieving a 97.3% gamma passing rate. However, VMAT planning revealed significant deviations (3.06% to 67.88%) between calculated and measured doses, with a significant difference (p < 0.01) and a 52.5% gamma passing rate for film dosimetry. PSQA for six patient plans yielded high gamma passing rates (97.5% to 100%) and absolute dose deviations ranging from 0.29% to 3.48%.Conclusion : Monaco TPS is reliable and accurately commissioned for 3DCRT planning but shows significant deviations in VMAT planning. Future efforts should aim to improve verification methods, address challenges in gamma index analysis, and enhance VMAT dose calculation accuracy for consistent treatment planning.
first_indexed 2024-12-09T02:32:19Z
format Thesis
id usm.eprints-61084
institution Universiti Sains Malaysia
language English
last_indexed 2024-12-09T02:32:19Z
publishDate 2024
record_format dspace
spelling usm.eprints-610842024-10-17T05:17:39Z http://eprints.usm.my/61084/ Dosimetric verification of monaco treatment planning system (TPS) in heterogeneous medium for 6 mv linac Azlan, Adriana Batrisyia Noor Mohd R Medicine RA440-440.87 Study and teaching. Research The Monaco TPS, employing the Monte Carlo dose calculation algorithm, offers high precision in radiotherapy planning. Accurate dose calculation in heterogeneous tissues necessitates comprehensive commissioning and verification due to its impact on patient outcomes. This study evaluates the dose calculation accuracy of Monaco TPS using Rando phantoms, thermoluminescence dosimeters (TLD-100) dosimeters, EBT3 Gafchromic films, and clinical patient data through patient-specific quality assurance (PSQA). Methods : Dosimetric verification of Monaco TPS was conducted on a head and neck Rando phantom for 3D conformal radiotherapy (3DCRT) whole brain radiotherapy (WBRT) and volumetric modulated arc therapy (VMAT) meningioma planning in heterogeneous environments, using 12 TLD-100s and EBT3 Gafchromic films. Additionally, six Eclipse TPS patient plans were replicated on Monaco TPS, and PSQA was performed using gamma criteria of 3% dose difference (DD) and 3 mm distance-to-agreement (DTA). Results :Monaco TPS demonstrated consistent percentage deviations within ±10% (ranging from 1.8% to 9.1%) between TPS calculated and TLD-measured doses for 3DCRT, with no significant difference (p > 0.05). EBT3 Gafchromic film dosimetry showed good agreement with TPS dose distributions, achieving a 97.3% gamma passing rate. However, VMAT planning revealed significant deviations (3.06% to 67.88%) between calculated and measured doses, with a significant difference (p < 0.01) and a 52.5% gamma passing rate for film dosimetry. PSQA for six patient plans yielded high gamma passing rates (97.5% to 100%) and absolute dose deviations ranging from 0.29% to 3.48%.Conclusion : Monaco TPS is reliable and accurately commissioned for 3DCRT planning but shows significant deviations in VMAT planning. Future efforts should aim to improve verification methods, address challenges in gamma index analysis, and enhance VMAT dose calculation accuracy for consistent treatment planning. 2024-07 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/61084/1/Adriana%20Batrisyia%20Noor%20Mohd%20Azlan-E.pdf Azlan, Adriana Batrisyia Noor Mohd (2024) Dosimetric verification of monaco treatment planning system (TPS) in heterogeneous medium for 6 mv linac. Other thesis, Universiti Sains Malaysia.
spellingShingle R Medicine
RA440-440.87 Study and teaching. Research
Azlan, Adriana Batrisyia Noor Mohd
Dosimetric verification of monaco treatment planning system (TPS) in heterogeneous medium for 6 mv linac
title Dosimetric verification of monaco treatment planning system (TPS) in heterogeneous medium for 6 mv linac
title_full Dosimetric verification of monaco treatment planning system (TPS) in heterogeneous medium for 6 mv linac
title_fullStr Dosimetric verification of monaco treatment planning system (TPS) in heterogeneous medium for 6 mv linac
title_full_unstemmed Dosimetric verification of monaco treatment planning system (TPS) in heterogeneous medium for 6 mv linac
title_short Dosimetric verification of monaco treatment planning system (TPS) in heterogeneous medium for 6 mv linac
title_sort dosimetric verification of monaco treatment planning system tps in heterogeneous medium for 6 mv linac
topic R Medicine
RA440-440.87 Study and teaching. Research
url http://eprints.usm.my/61084/1/Adriana%20Batrisyia%20Noor%20Mohd%20Azlan-E.pdf
work_keys_str_mv AT azlanadrianabatrisyianoormohd dosimetricverificationofmonacotreatmentplanningsystemtpsinheterogeneousmediumfor6mvlinac