Measurement of entrance surface air kerma by using direct method: a comparison study

Dosimetry has increasing its importance in the radiation safety culture and protection purpose. Assessment of entrance skin doses in conventional diagnostic radiology should be evaluated in order minimizing hazard in delivering optimum radiation dose amount. The entrance surface air kerma was det...

Full description

Bibliographic Details
Main Author: Roslan, Nur Amanina Izzati Mohd
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2016
Subjects:
Online Access:http://eprints.usm.my/61244/1/NUR%20AMANINA%20IZZATI%20BINTI%20MOHD%20ROSLAN-%20e.pdf
_version_ 1825908437035253760
author Roslan, Nur Amanina Izzati Mohd
author_facet Roslan, Nur Amanina Izzati Mohd
author_sort Roslan, Nur Amanina Izzati Mohd
collection USM
description Dosimetry has increasing its importance in the radiation safety culture and protection purpose. Assessment of entrance skin doses in conventional diagnostic radiology should be evaluated in order minimizing hazard in delivering optimum radiation dose amount. The entrance surface air kerma was determined by directly measured using TLDs in two common radiography examination PA chest and abdomen. Results were analyzed in variable objectives according to this study. Measurement using direct method done with selected parameter from the previous study by Taha et al., 2014. For parameter 81 kVp with 12.5mAs for anterioposterior (AP) projection of the abdomen, mean dose obtained was 1.96 mGy compared to previous study which value 2.50 mGy. were For chest radiograph procedure, parameter of were 125 kVp, 1.6 mAs, for posterioanterior (PA) projection give the mean dose of 0.21 mGy than the previous study at 0.14mGy. Eventhough the values does not achieved in similar, ESAK was still below the reference level suggested by IAEA (2004), 0.3 mGy for chest PA, and 10 mGy for abdomen AP. The result of this study showed that the ESAK values were still in acceptable range doses from common radiological examinations. Method of calculation can be used if the TED was available for ESAK measurement if its deviation quite small.
first_indexed 2024-12-09T02:32:29Z
format Monograph
id usm.eprints-61244
institution Universiti Sains Malaysia
language English
last_indexed 2024-12-09T02:32:29Z
publishDate 2016
publisher Universiti Sains Malaysia
record_format dspace
spelling usm.eprints-612442024-11-21T01:17:36Z http://eprints.usm.my/61244/ Measurement of entrance surface air kerma by using direct method: a comparison study Roslan, Nur Amanina Izzati Mohd RA0421 Public health. Hygiene. Preventive Medicine Dosimetry has increasing its importance in the radiation safety culture and protection purpose. Assessment of entrance skin doses in conventional diagnostic radiology should be evaluated in order minimizing hazard in delivering optimum radiation dose amount. The entrance surface air kerma was determined by directly measured using TLDs in two common radiography examination PA chest and abdomen. Results were analyzed in variable objectives according to this study. Measurement using direct method done with selected parameter from the previous study by Taha et al., 2014. For parameter 81 kVp with 12.5mAs for anterioposterior (AP) projection of the abdomen, mean dose obtained was 1.96 mGy compared to previous study which value 2.50 mGy. were For chest radiograph procedure, parameter of were 125 kVp, 1.6 mAs, for posterioanterior (PA) projection give the mean dose of 0.21 mGy than the previous study at 0.14mGy. Eventhough the values does not achieved in similar, ESAK was still below the reference level suggested by IAEA (2004), 0.3 mGy for chest PA, and 10 mGy for abdomen AP. The result of this study showed that the ESAK values were still in acceptable range doses from common radiological examinations. Method of calculation can be used if the TED was available for ESAK measurement if its deviation quite small. Universiti Sains Malaysia 2016 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/61244/1/NUR%20AMANINA%20IZZATI%20BINTI%20MOHD%20ROSLAN-%20e.pdf Roslan, Nur Amanina Izzati Mohd (2016) Measurement of entrance surface air kerma by using direct method: a comparison study. Project Report. Universiti Sains Malaysia. (Submitted)
spellingShingle RA0421 Public health. Hygiene. Preventive Medicine
Roslan, Nur Amanina Izzati Mohd
Measurement of entrance surface air kerma by using direct method: a comparison study
title Measurement of entrance surface air kerma by using direct method: a comparison study
title_full Measurement of entrance surface air kerma by using direct method: a comparison study
title_fullStr Measurement of entrance surface air kerma by using direct method: a comparison study
title_full_unstemmed Measurement of entrance surface air kerma by using direct method: a comparison study
title_short Measurement of entrance surface air kerma by using direct method: a comparison study
title_sort measurement of entrance surface air kerma by using direct method a comparison study
topic RA0421 Public health. Hygiene. Preventive Medicine
url http://eprints.usm.my/61244/1/NUR%20AMANINA%20IZZATI%20BINTI%20MOHD%20ROSLAN-%20e.pdf
work_keys_str_mv AT roslannuramaninaizzatimohd measurementofentrancesurfaceairkermabyusingdirectmethodacomparisonstudy