An implementation of regional descriptor and line roi in development of semi-automated strabismus detection system

The strabismus (squint) is one of children's most common vision disorders. It can cause discomfort and have a significant detrimental effect on daily life. A timely diagnosis is needed to prevent it from getting worse. However, the traditional diagnosis screening is usually done manually and re...

Full description

Bibliographic Details
Main Author: Zolkifli, Nur Syazlin
Format: Thesis
Language:English
English
English
Published: 2022
Subjects:
Online Access:http://eprints.uthm.edu.my/10966/1/24p%20NUR%20SYAZLIN%20%20ZOLKIFLI.pdf
http://eprints.uthm.edu.my/10966/2/NUR%20SYAZLIN%20%20ZOLKIFLI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/10966/3/NUR%20SYAZLIN%20%20ZOLKIFLI%20WATERMARK.pdf
_version_ 1825638449646927872
author Zolkifli, Nur Syazlin
author_facet Zolkifli, Nur Syazlin
author_sort Zolkifli, Nur Syazlin
collection UTHM
description The strabismus (squint) is one of children's most common vision disorders. It can cause discomfort and have a significant detrimental effect on daily life. A timely diagnosis is needed to prevent it from getting worse. However, the traditional diagnosis screening is usually done manually and requires expertise, time and high cost due to the equipment. Thus, the proposed semi-automated strabismus detection using computer-aided diagnosis can help to reduce the time for the ophthalmologist to diagnose the strabismus and the misalignment measurement. This research aims to propose the image processing approach for detection and diagnosis of strabismus. This research proposes three phases: pre-processing, feature extraction, and classification. Initially, the image in pre-processing undergoes Viola Jones algorithm, red channel extraction, contrast adjustment and median filtering to reduce the noise and enhance the image. In feature extraction, binarization and morphological operations are implemented to identify the location of the iris and the misalignment measurement. Finally, the classification is divided into two, where the coordinates of the iris and misalignment measurement are carried out using regional descriptor and line ROI, while the strabismus and non-strabismus are classified using Convolutional Neural Network (CNN). The experimental results have proven that the proposed method has successfully detected the strabismus and the misalignment measurement with an average accuracy for the Eye Disease dataset (0.9167), Google Images (0.9217), CAVE (0.9167), and SiblingsDB (0.9167). In conclusion, by utilizing the image processing approach, this system will be able to assist the ophthalmologist and health care practitioners as strabismus pre-screening tools
first_indexed 2024-09-24T00:09:00Z
format Thesis
id uthm.eprints-10966
institution Universiti Tun Hussein Onn Malaysia
language English
English
English
last_indexed 2024-09-24T00:09:00Z
publishDate 2022
record_format dspace
spelling uthm.eprints-109662024-05-15T07:19:17Z http://eprints.uthm.edu.my/10966/ An implementation of regional descriptor and line roi in development of semi-automated strabismus detection system Zolkifli, Nur Syazlin TJ Mechanical engineering and machinery The strabismus (squint) is one of children's most common vision disorders. It can cause discomfort and have a significant detrimental effect on daily life. A timely diagnosis is needed to prevent it from getting worse. However, the traditional diagnosis screening is usually done manually and requires expertise, time and high cost due to the equipment. Thus, the proposed semi-automated strabismus detection using computer-aided diagnosis can help to reduce the time for the ophthalmologist to diagnose the strabismus and the misalignment measurement. This research aims to propose the image processing approach for detection and diagnosis of strabismus. This research proposes three phases: pre-processing, feature extraction, and classification. Initially, the image in pre-processing undergoes Viola Jones algorithm, red channel extraction, contrast adjustment and median filtering to reduce the noise and enhance the image. In feature extraction, binarization and morphological operations are implemented to identify the location of the iris and the misalignment measurement. Finally, the classification is divided into two, where the coordinates of the iris and misalignment measurement are carried out using regional descriptor and line ROI, while the strabismus and non-strabismus are classified using Convolutional Neural Network (CNN). The experimental results have proven that the proposed method has successfully detected the strabismus and the misalignment measurement with an average accuracy for the Eye Disease dataset (0.9167), Google Images (0.9217), CAVE (0.9167), and SiblingsDB (0.9167). In conclusion, by utilizing the image processing approach, this system will be able to assist the ophthalmologist and health care practitioners as strabismus pre-screening tools 2022-11 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/10966/1/24p%20NUR%20SYAZLIN%20%20ZOLKIFLI.pdf text en http://eprints.uthm.edu.my/10966/2/NUR%20SYAZLIN%20%20ZOLKIFLI%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/10966/3/NUR%20SYAZLIN%20%20ZOLKIFLI%20WATERMARK.pdf Zolkifli, Nur Syazlin (2022) An implementation of regional descriptor and line roi in development of semi-automated strabismus detection system. Masters thesis, Universiti Tun Hussein Onn Malaysia.
spellingShingle TJ Mechanical engineering and machinery
Zolkifli, Nur Syazlin
An implementation of regional descriptor and line roi in development of semi-automated strabismus detection system
title An implementation of regional descriptor and line roi in development of semi-automated strabismus detection system
title_full An implementation of regional descriptor and line roi in development of semi-automated strabismus detection system
title_fullStr An implementation of regional descriptor and line roi in development of semi-automated strabismus detection system
title_full_unstemmed An implementation of regional descriptor and line roi in development of semi-automated strabismus detection system
title_short An implementation of regional descriptor and line roi in development of semi-automated strabismus detection system
title_sort implementation of regional descriptor and line roi in development of semi automated strabismus detection system
topic TJ Mechanical engineering and machinery
url http://eprints.uthm.edu.my/10966/1/24p%20NUR%20SYAZLIN%20%20ZOLKIFLI.pdf
http://eprints.uthm.edu.my/10966/2/NUR%20SYAZLIN%20%20ZOLKIFLI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/10966/3/NUR%20SYAZLIN%20%20ZOLKIFLI%20WATERMARK.pdf
work_keys_str_mv AT zolkiflinursyazlin animplementationofregionaldescriptorandlineroiindevelopmentofsemiautomatedstrabismusdetectionsystem
AT zolkiflinursyazlin implementationofregionaldescriptorandlineroiindevelopmentofsemiautomatedstrabismusdetectionsystem