Testbed on MANET (ToM): private testbed facility for MANET Experiment
This article aims to share how to create a minimum MANET testbed facility as a requirement for evaluation of MANET research. Testbed facility that we have developed is called as Testbed on MANET or abbreviation ToM. We chose to use single board computer (SBC) to represent mobile devices in MANET...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Springer
2019
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/1767/1/P12538_32837a97651a7e3deb479811e60e9d8d.pdf |
_version_ | 1825709601305133056 |
---|---|
author | Muchtar, Farkhana Al-Adhaileh, Mosleh Mohd Nordin, Ili Najaa Aimi Mohd Hanif, Asyikin Sasha Singh, Pradeep Kumar Zubair, Ajoze Abdulraheem Saheed, Ajibade Lukuman |
author_facet | Muchtar, Farkhana Al-Adhaileh, Mosleh Mohd Nordin, Ili Najaa Aimi Mohd Hanif, Asyikin Sasha Singh, Pradeep Kumar Zubair, Ajoze Abdulraheem Saheed, Ajibade Lukuman |
author_sort | Muchtar, Farkhana |
collection | UTHM |
description | This article aims to share how to create a minimum MANET testbed
facility as a requirement for evaluation of MANET research. Testbed facility
that we have developed is called as Testbed on MANET or abbreviation ToM.
We chose to use single board computer (SBC) to represent mobile devices in
MANET. ToM facility and can be used either in a static mesh network or in a
dynamic network topology, where each node in the testbed can move according
to the needs of the researcher. To realize a real world node mobility in ToM, we
use mobile robot technology and mobile robot that we have develop, where we
named it as ToMRobot. Our experience in developing a ToM facility proves that
with today’s technological developments, the private MANET testbed facility
can be developed more easily at low cost. |
first_indexed | 2024-03-05T21:41:03Z |
format | Article |
id | uthm.eprints-1767 |
institution | Universiti Tun Hussein Onn Malaysia |
language | English |
last_indexed | 2024-03-05T21:41:03Z |
publishDate | 2019 |
publisher | Springer |
record_format | dspace |
spelling | uthm.eprints-17672021-10-18T02:54:44Z http://eprints.uthm.edu.my/1767/ Testbed on MANET (ToM): private testbed facility for MANET Experiment Muchtar, Farkhana Al-Adhaileh, Mosleh Mohd Nordin, Ili Najaa Aimi Mohd Hanif, Asyikin Sasha Singh, Pradeep Kumar Zubair, Ajoze Abdulraheem Saheed, Ajibade Lukuman TK5101-6720 Telecommunication. Including telegraphy, telephone, radio, radar, television This article aims to share how to create a minimum MANET testbed facility as a requirement for evaluation of MANET research. Testbed facility that we have developed is called as Testbed on MANET or abbreviation ToM. We chose to use single board computer (SBC) to represent mobile devices in MANET. ToM facility and can be used either in a static mesh network or in a dynamic network topology, where each node in the testbed can move according to the needs of the researcher. To realize a real world node mobility in ToM, we use mobile robot technology and mobile robot that we have develop, where we named it as ToMRobot. Our experience in developing a ToM facility proves that with today’s technological developments, the private MANET testbed facility can be developed more easily at low cost. Springer 2019 Article PeerReviewed text en http://eprints.uthm.edu.my/1767/1/P12538_32837a97651a7e3deb479811e60e9d8d.pdf Muchtar, Farkhana and Al-Adhaileh, Mosleh and Mohd Nordin, Ili Najaa Aimi and Mohd Hanif, Asyikin Sasha and Singh, Pradeep Kumar and Zubair, Ajoze Abdulraheem and Saheed, Ajibade Lukuman (2019) Testbed on MANET (ToM): private testbed facility for MANET Experiment. International Conference on Futuristic Trends in Networks and Computing Technologies. pp. 129-145. https://doi.org/10.1007/978-981-15-4451-4_12 |
spellingShingle | TK5101-6720 Telecommunication. Including telegraphy, telephone, radio, radar, television Muchtar, Farkhana Al-Adhaileh, Mosleh Mohd Nordin, Ili Najaa Aimi Mohd Hanif, Asyikin Sasha Singh, Pradeep Kumar Zubair, Ajoze Abdulraheem Saheed, Ajibade Lukuman Testbed on MANET (ToM): private testbed facility for MANET Experiment |
title | Testbed on MANET (ToM): private testbed
facility for MANET Experiment |
title_full | Testbed on MANET (ToM): private testbed
facility for MANET Experiment |
title_fullStr | Testbed on MANET (ToM): private testbed
facility for MANET Experiment |
title_full_unstemmed | Testbed on MANET (ToM): private testbed
facility for MANET Experiment |
title_short | Testbed on MANET (ToM): private testbed
facility for MANET Experiment |
title_sort | testbed on manet tom private testbed facility for manet experiment |
topic | TK5101-6720 Telecommunication. Including telegraphy, telephone, radio, radar, television |
url | http://eprints.uthm.edu.my/1767/1/P12538_32837a97651a7e3deb479811e60e9d8d.pdf |
work_keys_str_mv | AT muchtarfarkhana testbedonmanettomprivatetestbedfacilityformanetexperiment AT aladhailehmosleh testbedonmanettomprivatetestbedfacilityformanetexperiment AT mohdnordinilinajaaaimi testbedonmanettomprivatetestbedfacilityformanetexperiment AT mohdhanifasyikinsasha testbedonmanettomprivatetestbedfacilityformanetexperiment AT singhpradeepkumar testbedonmanettomprivatetestbedfacilityformanetexperiment AT zubairajozeabdulraheem testbedonmanettomprivatetestbedfacilityformanetexperiment AT saheedajibadelukuman testbedonmanettomprivatetestbedfacilityformanetexperiment |