Analysis and evaluation of uncertainty for conducted and radiated emissions tests

Whenever an EMC measurement is made, there are numerous uncertainties in different parts of the measurement system and even in the EMC performance of the equipment under test (EUT) which is being measured. It is important to be able to estimate the overall uncertainty, in particular, the test set...

Full description

Bibliographic Details
Main Author: Abdurrahim, Mohamed Emhemed
Format: Thesis
Language:English
English
English
Published: 2013
Subjects:
Online Access:http://eprints.uthm.edu.my/1963/1/24p%20MOHAMED%20EMHEMED%20ABDURRAHIM.pdf
http://eprints.uthm.edu.my/1963/2/MOHAMED%20EMHEMED%20ABDURRAHIM%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1963/3/MOHAMED%20EMHEMED%20ABDURRAHIM%20WATERMARK.pdf
_version_ 1825709635385950208
author Abdurrahim, Mohamed Emhemed
author_facet Abdurrahim, Mohamed Emhemed
author_sort Abdurrahim, Mohamed Emhemed
collection UTHM
description Whenever an EMC measurement is made, there are numerous uncertainties in different parts of the measurement system and even in the EMC performance of the equipment under test (EUT) which is being measured. It is important to be able to estimate the overall uncertainty, in particular, the test setup and measurement equipment uncertainty. However, making repetitive measurements can reduce the measurement uncertainty, but often economics of time do not permit that. Therefore, a practical process, which is used to evaluate uncertainty in EMC measurement a, according to the principle of uncertainty and conditions in EMC measurement is presented. In this study, an efficient analysis of uncertainty for both radiated and conducted emissions tests is performed. The uncertainty of each contributor had been calculated and evaluating the reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement. This standard uncertainty is multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%. The result of calculating the uncertainty for both conducted and radiated emission tests showed that the overall uncertainty of the system is high and it must be lowered by reducing the expanded uncertainty for the dominant contributors for both tests. In addition, the result of applying the concept of CISPR uncertainty for both conducted and radiated emission tests showed that non-compliance is deemed to occur for both EUT of both tests. This is due to the result that the measured disturbances increased by ( ), above the disturbance limit.
first_indexed 2024-03-05T21:41:34Z
format Thesis
id uthm.eprints-1963
institution Universiti Tun Hussein Onn Malaysia
language English
English
English
last_indexed 2024-03-05T21:41:34Z
publishDate 2013
record_format dspace
spelling uthm.eprints-19632021-10-14T05:45:00Z http://eprints.uthm.edu.my/1963/ Analysis and evaluation of uncertainty for conducted and radiated emissions tests Abdurrahim, Mohamed Emhemed TK Electrical engineering. Electronics Nuclear engineering TK5101-6720 Telecommunication. Including telegraphy, telephone, radio, radar, television Whenever an EMC measurement is made, there are numerous uncertainties in different parts of the measurement system and even in the EMC performance of the equipment under test (EUT) which is being measured. It is important to be able to estimate the overall uncertainty, in particular, the test setup and measurement equipment uncertainty. However, making repetitive measurements can reduce the measurement uncertainty, but often economics of time do not permit that. Therefore, a practical process, which is used to evaluate uncertainty in EMC measurement a, according to the principle of uncertainty and conditions in EMC measurement is presented. In this study, an efficient analysis of uncertainty for both radiated and conducted emissions tests is performed. The uncertainty of each contributor had been calculated and evaluating the reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement. This standard uncertainty is multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%. The result of calculating the uncertainty for both conducted and radiated emission tests showed that the overall uncertainty of the system is high and it must be lowered by reducing the expanded uncertainty for the dominant contributors for both tests. In addition, the result of applying the concept of CISPR uncertainty for both conducted and radiated emission tests showed that non-compliance is deemed to occur for both EUT of both tests. This is due to the result that the measured disturbances increased by ( ), above the disturbance limit. 2013-01 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/1963/1/24p%20MOHAMED%20EMHEMED%20ABDURRAHIM.pdf text en http://eprints.uthm.edu.my/1963/2/MOHAMED%20EMHEMED%20ABDURRAHIM%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/1963/3/MOHAMED%20EMHEMED%20ABDURRAHIM%20WATERMARK.pdf Abdurrahim, Mohamed Emhemed (2013) Analysis and evaluation of uncertainty for conducted and radiated emissions tests. Masters thesis, Universiti Tun Hussein Malaysia.
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
TK5101-6720 Telecommunication. Including telegraphy, telephone, radio, radar, television
Abdurrahim, Mohamed Emhemed
Analysis and evaluation of uncertainty for conducted and radiated emissions tests
title Analysis and evaluation of uncertainty for conducted and radiated emissions tests
title_full Analysis and evaluation of uncertainty for conducted and radiated emissions tests
title_fullStr Analysis and evaluation of uncertainty for conducted and radiated emissions tests
title_full_unstemmed Analysis and evaluation of uncertainty for conducted and radiated emissions tests
title_short Analysis and evaluation of uncertainty for conducted and radiated emissions tests
title_sort analysis and evaluation of uncertainty for conducted and radiated emissions tests
topic TK Electrical engineering. Electronics Nuclear engineering
TK5101-6720 Telecommunication. Including telegraphy, telephone, radio, radar, television
url http://eprints.uthm.edu.my/1963/1/24p%20MOHAMED%20EMHEMED%20ABDURRAHIM.pdf
http://eprints.uthm.edu.my/1963/2/MOHAMED%20EMHEMED%20ABDURRAHIM%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1963/3/MOHAMED%20EMHEMED%20ABDURRAHIM%20WATERMARK.pdf
work_keys_str_mv AT abdurrahimmohamedemhemed analysisandevaluationofuncertaintyforconductedandradiatedemissionstests