Improvement of speed response in four-phase DC–DC converter switching using two shunt voltage-source

This study proposes a technique that is able to improve the speed response of a four-phase DC–DC converter switching. The basic concept of the proposed technique is the inclusion of two shunt-connected voltage sources in series to the converter system. Using a higher input voltage to drive the load,...

Full description

Bibliographic Details
Main Authors: A. Yahaya, Jabbar, Mansor, Muhamad, Sulaiman, Suhaila
Format: Article
Language:English
Published: Institution of Engineering and Technology (IET) 2018
Subjects:
Online Access:http://eprints.uthm.edu.my/2847/1/AJ%202019%20%2842%29.pdf
_version_ 1825709745629036544
author A. Yahaya, Jabbar
Mansor, Muhamad
Sulaiman, Suhaila
author_facet A. Yahaya, Jabbar
Mansor, Muhamad
Sulaiman, Suhaila
author_sort A. Yahaya, Jabbar
collection UTHM
description This study proposes a technique that is able to improve the speed response of a four-phase DC–DC converter switching. The basic concept of the proposed technique is the inclusion of two shunt-connected voltage sources in series to the converter system. Using a higher input voltage to drive the load, a higher current per microsecond output system will be obtained and reverts to its nominal input upon obtaining desired references. Thus, the transient response observed when using this proposed technique is found to be much faster when compared to the conventional converter. Moreover, this technique is easily implemented as it requires only an additional voltage source, power switch, and power diode. The integrated model of the two shunt voltage-source in a four-phase DC–DC converter was simulated in MATLAB/Simulink and validated against the experimental results of a laboratory prototype, 600 W four-phase DC–DC converter. The novelty of this proposed technique is its ability to provide faster operations for critical loads applications, lower output capacitor and lower operating frequency.
first_indexed 2024-03-05T21:44:07Z
format Article
id uthm.eprints-2847
institution Universiti Tun Hussein Onn Malaysia
language English
last_indexed 2024-03-05T21:44:07Z
publishDate 2018
publisher Institution of Engineering and Technology (IET)
record_format dspace
spelling uthm.eprints-28472021-11-15T06:45:11Z http://eprints.uthm.edu.my/2847/ Improvement of speed response in four-phase DC–DC converter switching using two shunt voltage-source A. Yahaya, Jabbar Mansor, Muhamad Sulaiman, Suhaila TK1001-1841 Production of electric energy or power. Powerplants. Central stations This study proposes a technique that is able to improve the speed response of a four-phase DC–DC converter switching. The basic concept of the proposed technique is the inclusion of two shunt-connected voltage sources in series to the converter system. Using a higher input voltage to drive the load, a higher current per microsecond output system will be obtained and reverts to its nominal input upon obtaining desired references. Thus, the transient response observed when using this proposed technique is found to be much faster when compared to the conventional converter. Moreover, this technique is easily implemented as it requires only an additional voltage source, power switch, and power diode. The integrated model of the two shunt voltage-source in a four-phase DC–DC converter was simulated in MATLAB/Simulink and validated against the experimental results of a laboratory prototype, 600 W four-phase DC–DC converter. The novelty of this proposed technique is its ability to provide faster operations for critical loads applications, lower output capacitor and lower operating frequency. Institution of Engineering and Technology (IET) 2018 Article PeerReviewed text en http://eprints.uthm.edu.my/2847/1/AJ%202019%20%2842%29.pdf A. Yahaya, Jabbar and Mansor, Muhamad and Sulaiman, Suhaila (2018) Improvement of speed response in four-phase DC–DC converter switching using two shunt voltage-source. IET Power Electronics, 11 (2). p. 1. ISSN 1755-4543 http://dspace.uniten.edu.my/jspui/handle/123456789/10475
spellingShingle TK1001-1841 Production of electric energy or power. Powerplants. Central stations
A. Yahaya, Jabbar
Mansor, Muhamad
Sulaiman, Suhaila
Improvement of speed response in four-phase DC–DC converter switching using two shunt voltage-source
title Improvement of speed response in four-phase DC–DC converter switching using two shunt voltage-source
title_full Improvement of speed response in four-phase DC–DC converter switching using two shunt voltage-source
title_fullStr Improvement of speed response in four-phase DC–DC converter switching using two shunt voltage-source
title_full_unstemmed Improvement of speed response in four-phase DC–DC converter switching using two shunt voltage-source
title_short Improvement of speed response in four-phase DC–DC converter switching using two shunt voltage-source
title_sort improvement of speed response in four phase dc dc converter switching using two shunt voltage source
topic TK1001-1841 Production of electric energy or power. Powerplants. Central stations
url http://eprints.uthm.edu.my/2847/1/AJ%202019%20%2842%29.pdf
work_keys_str_mv AT ayahayajabbar improvementofspeedresponseinfourphasedcdcconverterswitchingusingtwoshuntvoltagesource
AT mansormuhamad improvementofspeedresponseinfourphasedcdcconverterswitchingusingtwoshuntvoltagesource
AT sulaimansuhaila improvementofspeedresponseinfourphasedcdcconverterswitchingusingtwoshuntvoltagesource