Performance evaluation of a split unit air-conditioner retrofitted with Hydrocarbon Refrigerant (HC22)

The performance evaluation of a small capacity split unit air-conditioner when retrofitted with hydrocarbon refrigerant (HC22) was presented in this paper. Unlike traditional hydrofluorocarbon refrigerant (HCFC22) which possess ozone depletion potential (ODP) and high global warming potential (GW...

Full description

Bibliographic Details
Main Authors: Sabudin, Sulastri, Mohamad Noor, Mohamad Syafiq, Abdullah, Mohammad Kamil, Mohideen Batcha, Mohd Faizal, Taweekun, Juntakan
Format: Article
Language:English
Published: Penerbit Akademia Baru 2021
Subjects:
Online Access:http://eprints.uthm.edu.my/2949/1/J12666_a7676dff9a4180b2a43bc2a44bf3740a.pdf
_version_ 1796868746272309248
author Sabudin, Sulastri
Mohamad Noor, Mohamad Syafiq
Abdullah, Mohammad Kamil
Mohideen Batcha, Mohd Faizal
Taweekun, Juntakan
author_facet Sabudin, Sulastri
Mohamad Noor, Mohamad Syafiq
Abdullah, Mohammad Kamil
Mohideen Batcha, Mohd Faizal
Taweekun, Juntakan
author_sort Sabudin, Sulastri
collection UTHM
description The performance evaluation of a small capacity split unit air-conditioner when retrofitted with hydrocarbon refrigerant (HC22) was presented in this paper. Unlike traditional hydrofluorocarbon refrigerant (HCFC22) which possess ozone depletion potential (ODP) and high global warming potential (GWP), the HC22 refrigerant has zero ODP and a GWP value less than 3. Experimental work was carried out in a controlled environment which mimics an office room, with surrounding temperature varied from 25°C, 30°C and 35°C to simulate the typical cooling loads in Malaysia. The performance of HC22 refrigerant was compared with that of HCFC22 at these temperatures. The results show that the coefficient of performance (COP) of HC22 is higher, ranging from 3.5% to about 11% in comparison to HC22. The observation during experiments also shows that a typical HCFC22 can be retrofitted without any issue. The COP values obtained were 6.03, 6.35 and 6.15 for HC22 and 5.71, 5.66 and 5.63 for HCFC22 respectively. It can be concluded from this study that HC22 can be retrofitted directly to a HCFC system but other issues such as refrigerant flammability and safety issues shall be taken into account.
first_indexed 2024-03-05T21:44:25Z
format Article
id uthm.eprints-2949
institution Universiti Tun Hussein Onn Malaysia
language English
last_indexed 2024-03-05T21:44:25Z
publishDate 2021
publisher Penerbit Akademia Baru
record_format dspace
spelling uthm.eprints-29492021-11-16T04:30:37Z http://eprints.uthm.edu.my/2949/ Performance evaluation of a split unit air-conditioner retrofitted with Hydrocarbon Refrigerant (HC22) Sabudin, Sulastri Mohamad Noor, Mohamad Syafiq Abdullah, Mohammad Kamil Mohideen Batcha, Mohd Faizal Taweekun, Juntakan TH7005-7699 Heating and ventilation. Air conditioning The performance evaluation of a small capacity split unit air-conditioner when retrofitted with hydrocarbon refrigerant (HC22) was presented in this paper. Unlike traditional hydrofluorocarbon refrigerant (HCFC22) which possess ozone depletion potential (ODP) and high global warming potential (GWP), the HC22 refrigerant has zero ODP and a GWP value less than 3. Experimental work was carried out in a controlled environment which mimics an office room, with surrounding temperature varied from 25°C, 30°C and 35°C to simulate the typical cooling loads in Malaysia. The performance of HC22 refrigerant was compared with that of HCFC22 at these temperatures. The results show that the coefficient of performance (COP) of HC22 is higher, ranging from 3.5% to about 11% in comparison to HC22. The observation during experiments also shows that a typical HCFC22 can be retrofitted without any issue. The COP values obtained were 6.03, 6.35 and 6.15 for HC22 and 5.71, 5.66 and 5.63 for HCFC22 respectively. It can be concluded from this study that HC22 can be retrofitted directly to a HCFC system but other issues such as refrigerant flammability and safety issues shall be taken into account. Penerbit Akademia Baru 2021 Article PeerReviewed text en http://eprints.uthm.edu.my/2949/1/J12666_a7676dff9a4180b2a43bc2a44bf3740a.pdf Sabudin, Sulastri and Mohamad Noor, Mohamad Syafiq and Abdullah, Mohammad Kamil and Mohideen Batcha, Mohd Faizal and Taweekun, Juntakan (2021) Performance evaluation of a split unit air-conditioner retrofitted with Hydrocarbon Refrigerant (HC22). Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 81 (1). pp. 126-132. ISSN 2289-7879 https://doi.org/10.37934/arfmts.82.1.126132
spellingShingle TH7005-7699 Heating and ventilation. Air conditioning
Sabudin, Sulastri
Mohamad Noor, Mohamad Syafiq
Abdullah, Mohammad Kamil
Mohideen Batcha, Mohd Faizal
Taweekun, Juntakan
Performance evaluation of a split unit air-conditioner retrofitted with Hydrocarbon Refrigerant (HC22)
title Performance evaluation of a split unit air-conditioner retrofitted with Hydrocarbon Refrigerant (HC22)
title_full Performance evaluation of a split unit air-conditioner retrofitted with Hydrocarbon Refrigerant (HC22)
title_fullStr Performance evaluation of a split unit air-conditioner retrofitted with Hydrocarbon Refrigerant (HC22)
title_full_unstemmed Performance evaluation of a split unit air-conditioner retrofitted with Hydrocarbon Refrigerant (HC22)
title_short Performance evaluation of a split unit air-conditioner retrofitted with Hydrocarbon Refrigerant (HC22)
title_sort performance evaluation of a split unit air conditioner retrofitted with hydrocarbon refrigerant hc22
topic TH7005-7699 Heating and ventilation. Air conditioning
url http://eprints.uthm.edu.my/2949/1/J12666_a7676dff9a4180b2a43bc2a44bf3740a.pdf
work_keys_str_mv AT sabudinsulastri performanceevaluationofasplitunitairconditionerretrofittedwithhydrocarbonrefrigeranthc22
AT mohamadnoormohamadsyafiq performanceevaluationofasplitunitairconditionerretrofittedwithhydrocarbonrefrigeranthc22
AT abdullahmohammadkamil performanceevaluationofasplitunitairconditionerretrofittedwithhydrocarbonrefrigeranthc22
AT mohideenbatchamohdfaizal performanceevaluationofasplitunitairconditionerretrofittedwithhydrocarbonrefrigeranthc22
AT taweekunjuntakan performanceevaluationofasplitunitairconditionerretrofittedwithhydrocarbonrefrigeranthc22