Analysis and observation of grid connected single phase inverter integration
A single-phase grid connected with a photovoltaic (PV) power system that will provide high voltage gain with state model analysis for the control of the system has been presented. In addition to the solar panels, the system is equipped with a dc–dc converter, which allows the panels’ maximum powe...
Main Author: | |
---|---|
Format: | Thesis |
Language: | English English English |
Published: |
2020
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/381/1/24p%20ALI%20MOHAMED%20ALI%20ATEYA.pdf http://eprints.uthm.edu.my/381/2/ALI%20MOHAMED%20ALI%20ATEYA%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/381/3/ALI%20MOHAMED%20ALI%20ATEYA%20WATERMARK.pdf |
_version_ | 1825636459226333184 |
---|---|
author | Ali Ateya, Ali Mohamed |
author_facet | Ali Ateya, Ali Mohamed |
author_sort | Ali Ateya, Ali Mohamed |
collection | UTHM |
description | A single-phase grid connected with a photovoltaic (PV) power system that will provide
high voltage gain with state model analysis for the control of the system has been
presented. In addition to the solar panels, the system is equipped with a dc–dc
converter, which allows the panels’ maximum power point to be tracked, a singlephase
inverter and PI controller, all connected to a single-phase utility grid. The
maximum power point is maintained with a perturb and observe method. A PI
controller is used to control the power injected into the grid. The controller is used to
generate PWM and also controlling extra power. The maximum power delivered, and
it is synchronized with help of PWM to improve the power quality and system
efficiency. In this project the design separated in closed loop and open loop designs.
The result in both designs are different where is the voltage will be increase up to
3.214% more in closed loop design. Also, the power will increase up to 27.78% in
closed loop design. |
first_indexed | 2024-03-05T21:37:10Z |
format | Thesis |
id | uthm.eprints-381 |
institution | Universiti Tun Hussein Onn Malaysia |
language | English English English |
last_indexed | 2024-03-05T21:37:10Z |
publishDate | 2020 |
record_format | dspace |
spelling | uthm.eprints-3812021-07-25T01:27:10Z http://eprints.uthm.edu.my/381/ Analysis and observation of grid connected single phase inverter integration Ali Ateya, Ali Mohamed TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers A single-phase grid connected with a photovoltaic (PV) power system that will provide high voltage gain with state model analysis for the control of the system has been presented. In addition to the solar panels, the system is equipped with a dc–dc converter, which allows the panels’ maximum power point to be tracked, a singlephase inverter and PI controller, all connected to a single-phase utility grid. The maximum power point is maintained with a perturb and observe method. A PI controller is used to control the power injected into the grid. The controller is used to generate PWM and also controlling extra power. The maximum power delivered, and it is synchronized with help of PWM to improve the power quality and system efficiency. In this project the design separated in closed loop and open loop designs. The result in both designs are different where is the voltage will be increase up to 3.214% more in closed loop design. Also, the power will increase up to 27.78% in closed loop design. 2020-01 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/381/1/24p%20ALI%20MOHAMED%20ALI%20ATEYA.pdf text en http://eprints.uthm.edu.my/381/2/ALI%20MOHAMED%20ALI%20ATEYA%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/381/3/ALI%20MOHAMED%20ALI%20ATEYA%20WATERMARK.pdf Ali Ateya, Ali Mohamed (2020) Analysis and observation of grid connected single phase inverter integration. Masters thesis, Universiti Tun Hussein Onn Malaysia. |
spellingShingle | TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers Ali Ateya, Ali Mohamed Analysis and observation of grid connected single phase inverter integration |
title | Analysis and observation of grid connected single phase inverter integration |
title_full | Analysis and observation of grid connected single phase inverter integration |
title_fullStr | Analysis and observation of grid connected single phase inverter integration |
title_full_unstemmed | Analysis and observation of grid connected single phase inverter integration |
title_short | Analysis and observation of grid connected single phase inverter integration |
title_sort | analysis and observation of grid connected single phase inverter integration |
topic | TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers |
url | http://eprints.uthm.edu.my/381/1/24p%20ALI%20MOHAMED%20ALI%20ATEYA.pdf http://eprints.uthm.edu.my/381/2/ALI%20MOHAMED%20ALI%20ATEYA%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/381/3/ALI%20MOHAMED%20ALI%20ATEYA%20WATERMARK.pdf |
work_keys_str_mv | AT aliateyaalimohamed analysisandobservationofgridconnectedsinglephaseinverterintegration |