Single phase inverter system using proportional resonant current control

This paper presents the harmonic reduction performance of proportional resonant (PR) current controller in single phase inverter system connected to nonlinear load. In the study, proportional resonant current controller and low pass filter is discussed to eliminate low order harmonics injection in s...

Full description

Bibliographic Details
Main Authors: Chen, K.C., Salimin, Suriana, Zulkifli, S. A., Aziz, Rebaz
Format: Article
Published: Institute of Advanced Engineering and Science (IAES) 2017
Subjects:
_version_ 1825637178326122496
author Chen, K.C.
Salimin, Suriana
Zulkifli, S. A.
Aziz, Rebaz
author_facet Chen, K.C.
Salimin, Suriana
Zulkifli, S. A.
Aziz, Rebaz
author_sort Chen, K.C.
collection UTHM
description This paper presents the harmonic reduction performance of proportional resonant (PR) current controller in single phase inverter system connected to nonlinear load. In the study, proportional resonant current controller and low pass filter is discussed to eliminate low order harmonics injection in single phase inverter system. The potential of nonlinear load in producing harmonics is showed and identified by developing a nonlinear load model using a full bridge rectifier circuit. The modelling and simulation is done in MATLAB Simulink while harmonic spectrum results are obtained using Fast Fourier Transfor. End result show PR current controller capability to overcome the injection of current harmonic problems thus improved the overall total harmonic distortion (THD).
first_indexed 2024-03-05T21:47:16Z
format Article
id uthm.eprints-3975
institution Universiti Tun Hussein Onn Malaysia
last_indexed 2024-03-05T21:47:16Z
publishDate 2017
publisher Institute of Advanced Engineering and Science (IAES)
record_format dspace
spelling uthm.eprints-39752021-11-23T05:46:40Z http://eprints.uthm.edu.my/3975/ Single phase inverter system using proportional resonant current control Chen, K.C. Salimin, Suriana Zulkifli, S. A. Aziz, Rebaz TK1001-1841 Production of electric energy or power. Powerplants. Central stations This paper presents the harmonic reduction performance of proportional resonant (PR) current controller in single phase inverter system connected to nonlinear load. In the study, proportional resonant current controller and low pass filter is discussed to eliminate low order harmonics injection in single phase inverter system. The potential of nonlinear load in producing harmonics is showed and identified by developing a nonlinear load model using a full bridge rectifier circuit. The modelling and simulation is done in MATLAB Simulink while harmonic spectrum results are obtained using Fast Fourier Transfor. End result show PR current controller capability to overcome the injection of current harmonic problems thus improved the overall total harmonic distortion (THD). Institute of Advanced Engineering and Science (IAES) 2017 Article PeerReviewed Chen, K.C. and Salimin, Suriana and Zulkifli, S. A. and Aziz, Rebaz (2017) Single phase inverter system using proportional resonant current control. International Journal of Power Electronics and Drive System (IJPEDS), 8 (4). pp. 1913-1918. ISSN 2088-8694 https://dx.doi.org/10.11591/ijpeds.v8.i4.pp1913-1918
spellingShingle TK1001-1841 Production of electric energy or power. Powerplants. Central stations
Chen, K.C.
Salimin, Suriana
Zulkifli, S. A.
Aziz, Rebaz
Single phase inverter system using proportional resonant current control
title Single phase inverter system using proportional resonant current control
title_full Single phase inverter system using proportional resonant current control
title_fullStr Single phase inverter system using proportional resonant current control
title_full_unstemmed Single phase inverter system using proportional resonant current control
title_short Single phase inverter system using proportional resonant current control
title_sort single phase inverter system using proportional resonant current control
topic TK1001-1841 Production of electric energy or power. Powerplants. Central stations
work_keys_str_mv AT chenkc singlephaseinvertersystemusingproportionalresonantcurrentcontrol
AT saliminsuriana singlephaseinvertersystemusingproportionalresonantcurrentcontrol
AT zulkiflisa singlephaseinvertersystemusingproportionalresonantcurrentcontrol
AT azizrebaz singlephaseinvertersystemusingproportionalresonantcurrentcontrol