Single phase inverter system using proportional resonant current control
This paper presents the harmonic reduction performance of proportional resonant (PR) current controller in single phase inverter system connected to nonlinear load. In the study, proportional resonant current controller and low pass filter is discussed to eliminate low order harmonics injection in s...
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
Institute of Advanced Engineering and Science (IAES)
2017
|
Subjects: |
_version_ | 1825637178326122496 |
---|---|
author | Chen, K.C. Salimin, Suriana Zulkifli, S. A. Aziz, Rebaz |
author_facet | Chen, K.C. Salimin, Suriana Zulkifli, S. A. Aziz, Rebaz |
author_sort | Chen, K.C. |
collection | UTHM |
description | This paper presents the harmonic reduction performance of proportional resonant (PR) current controller in single phase inverter system connected to nonlinear load. In the study, proportional resonant current controller and low pass filter is discussed to eliminate low order harmonics injection in single phase inverter system. The potential of nonlinear load in producing harmonics is showed and identified by developing a nonlinear load model using a full bridge rectifier circuit. The modelling and simulation is done in MATLAB Simulink while harmonic spectrum results are obtained using Fast Fourier Transfor. End result show PR current controller capability to overcome the injection of current harmonic problems thus improved the overall total harmonic distortion (THD). |
first_indexed | 2024-03-05T21:47:16Z |
format | Article |
id | uthm.eprints-3975 |
institution | Universiti Tun Hussein Onn Malaysia |
last_indexed | 2024-03-05T21:47:16Z |
publishDate | 2017 |
publisher | Institute of Advanced Engineering and Science (IAES) |
record_format | dspace |
spelling | uthm.eprints-39752021-11-23T05:46:40Z http://eprints.uthm.edu.my/3975/ Single phase inverter system using proportional resonant current control Chen, K.C. Salimin, Suriana Zulkifli, S. A. Aziz, Rebaz TK1001-1841 Production of electric energy or power. Powerplants. Central stations This paper presents the harmonic reduction performance of proportional resonant (PR) current controller in single phase inverter system connected to nonlinear load. In the study, proportional resonant current controller and low pass filter is discussed to eliminate low order harmonics injection in single phase inverter system. The potential of nonlinear load in producing harmonics is showed and identified by developing a nonlinear load model using a full bridge rectifier circuit. The modelling and simulation is done in MATLAB Simulink while harmonic spectrum results are obtained using Fast Fourier Transfor. End result show PR current controller capability to overcome the injection of current harmonic problems thus improved the overall total harmonic distortion (THD). Institute of Advanced Engineering and Science (IAES) 2017 Article PeerReviewed Chen, K.C. and Salimin, Suriana and Zulkifli, S. A. and Aziz, Rebaz (2017) Single phase inverter system using proportional resonant current control. International Journal of Power Electronics and Drive System (IJPEDS), 8 (4). pp. 1913-1918. ISSN 2088-8694 https://dx.doi.org/10.11591/ijpeds.v8.i4.pp1913-1918 |
spellingShingle | TK1001-1841 Production of electric energy or power. Powerplants. Central stations Chen, K.C. Salimin, Suriana Zulkifli, S. A. Aziz, Rebaz Single phase inverter system using proportional resonant current control |
title | Single phase inverter system using proportional resonant current control |
title_full | Single phase inverter system using proportional resonant current control |
title_fullStr | Single phase inverter system using proportional resonant current control |
title_full_unstemmed | Single phase inverter system using proportional resonant current control |
title_short | Single phase inverter system using proportional resonant current control |
title_sort | single phase inverter system using proportional resonant current control |
topic | TK1001-1841 Production of electric energy or power. Powerplants. Central stations |
work_keys_str_mv | AT chenkc singlephaseinvertersystemusingproportionalresonantcurrentcontrol AT saliminsuriana singlephaseinvertersystemusingproportionalresonantcurrentcontrol AT zulkiflisa singlephaseinvertersystemusingproportionalresonantcurrentcontrol AT azizrebaz singlephaseinvertersystemusingproportionalresonantcurrentcontrol |