Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr

This paper describes the source of voltage sag occurring in the power system. Voltage sag can occur in the system by means of having line faulty, inrush current drawn by loads and switching operation. However, the unbalanced load in the system causing voltage sag is studied here. In this paper,...

Full description

Bibliographic Details
Main Authors: Soomro, Dur Muhammad, Wei Keat, Yew, Baloch, Mazhar Hussain, Abdullah, Mohd Noor, Mohammad Radzi, Nur Hanis, Ahmed Memon, Zubair
Format: Conference or Workshop Item
Language:English
Subjects:
Online Access:http://eprints.uthm.edu.my/4501/1/KP%202020%20%2890%29.pdf
_version_ 1825709857303429120
author Soomro, Dur Muhammad
Wei Keat, Yew
Baloch, Mazhar Hussain
Abdullah, Mohd Noor
Mohammad Radzi, Nur Hanis
Ahmed Memon, Zubair
author_facet Soomro, Dur Muhammad
Wei Keat, Yew
Baloch, Mazhar Hussain
Abdullah, Mohd Noor
Mohammad Radzi, Nur Hanis
Ahmed Memon, Zubair
author_sort Soomro, Dur Muhammad
collection UTHM
description This paper describes the source of voltage sag occurring in the power system. Voltage sag can occur in the system by means of having line faulty, inrush current drawn by loads and switching operation. However, the unbalanced load in the system causing voltage sag is studied here. In this paper, the pattern of voltage sag caused by balanced three phase (3Ø) and unbalanced single phase (1Ø) loads are studied and compared. The percentage of voltage sag caused by both cases are calculated using voltage sag calculation formulae by keeping definition values of sag between 10% - 90% as stated in IEEE Std. 1159-2009. While the percentage of voltage unbalance in the system caused by 1Ø unbalanced loads is calculated by using voltage unbalance formulae. The philosophy of voltage sag mitigation is studied by using a proposed mitigation device after studied the causes of voltage sag. There are several researches that have been done by proposing different kind of devices. The Dynamic Voltage Restorer (DVR) is one of the most cost-effective methods to protect the sensitive loads in the system for mitigating the voltage sag. The voltage sag is mitigated by injecting voltage dynamically to compensate the voltage differences between normal input supply and disturbed output supply. In order to achieve the voltage injection into the system dynamically to mitigate voltage sag, a control technique has to be applied on the DVR. There are many control techniques which are applied on the DVR to mitigate the voltage sag, such as the Direct-Quadrature-Zero (dq0), Fuzzy Logic (FL) and Space Vector Pulse Width Modulation (SVPWM). The Discrete Fourier Transform (DFT) is one of the control techniques which is implemented on the DVR in this paper. The modeling and simulation results of the DFT controlled DVR were carried out by using MATLAB/Simulink to validity the performance of the sag mitigation. As a result, the DFT controlled DVR was successfully designed and 100% mitigated the voltage sag both with balanced and unbalanced loads in the system.
first_indexed 2024-03-05T21:48:45Z
format Conference or Workshop Item
id uthm.eprints-4501
institution Universiti Tun Hussein Onn Malaysia
language English
last_indexed 2024-03-05T21:48:45Z
record_format dspace
spelling uthm.eprints-45012022-01-23T07:55:23Z http://eprints.uthm.edu.my/4501/ Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr Soomro, Dur Muhammad Wei Keat, Yew Baloch, Mazhar Hussain Abdullah, Mohd Noor Mohammad Radzi, Nur Hanis Ahmed Memon, Zubair TK3001-3521 Distribution or transmission of electric power This paper describes the source of voltage sag occurring in the power system. Voltage sag can occur in the system by means of having line faulty, inrush current drawn by loads and switching operation. However, the unbalanced load in the system causing voltage sag is studied here. In this paper, the pattern of voltage sag caused by balanced three phase (3Ø) and unbalanced single phase (1Ø) loads are studied and compared. The percentage of voltage sag caused by both cases are calculated using voltage sag calculation formulae by keeping definition values of sag between 10% - 90% as stated in IEEE Std. 1159-2009. While the percentage of voltage unbalance in the system caused by 1Ø unbalanced loads is calculated by using voltage unbalance formulae. The philosophy of voltage sag mitigation is studied by using a proposed mitigation device after studied the causes of voltage sag. There are several researches that have been done by proposing different kind of devices. The Dynamic Voltage Restorer (DVR) is one of the most cost-effective methods to protect the sensitive loads in the system for mitigating the voltage sag. The voltage sag is mitigated by injecting voltage dynamically to compensate the voltage differences between normal input supply and disturbed output supply. In order to achieve the voltage injection into the system dynamically to mitigate voltage sag, a control technique has to be applied on the DVR. There are many control techniques which are applied on the DVR to mitigate the voltage sag, such as the Direct-Quadrature-Zero (dq0), Fuzzy Logic (FL) and Space Vector Pulse Width Modulation (SVPWM). The Discrete Fourier Transform (DFT) is one of the control techniques which is implemented on the DVR in this paper. The modeling and simulation results of the DFT controlled DVR were carried out by using MATLAB/Simulink to validity the performance of the sag mitigation. As a result, the DFT controlled DVR was successfully designed and 100% mitigated the voltage sag both with balanced and unbalanced loads in the system. Conference or Workshop Item PeerReviewed text en http://eprints.uthm.edu.my/4501/1/KP%202020%20%2890%29.pdf Soomro, Dur Muhammad and Wei Keat, Yew and Baloch, Mazhar Hussain and Abdullah, Mohd Noor and Mohammad Radzi, Nur Hanis and Ahmed Memon, Zubair Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr. In: 2019 IEEE International Conference on Innovative Research and Development (ICIRD), 28-30 June 2019, Jakarta, Indonesia. http://DOI:10.1109/ICIRD47319.2019.9074727
spellingShingle TK3001-3521 Distribution or transmission of electric power
Soomro, Dur Muhammad
Wei Keat, Yew
Baloch, Mazhar Hussain
Abdullah, Mohd Noor
Mohammad Radzi, Nur Hanis
Ahmed Memon, Zubair
Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr
title Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr
title_full Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr
title_fullStr Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr
title_full_unstemmed Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr
title_short Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr
title_sort mitigation of voltage sag caused by unbalanced load by using dft controlled dvr
topic TK3001-3521 Distribution or transmission of electric power
url http://eprints.uthm.edu.my/4501/1/KP%202020%20%2890%29.pdf
work_keys_str_mv AT soomrodurmuhammad mitigationofvoltagesagcausedbyunbalancedloadbyusingdftcontrolleddvr
AT weikeatyew mitigationofvoltagesagcausedbyunbalancedloadbyusingdftcontrolleddvr
AT balochmazharhussain mitigationofvoltagesagcausedbyunbalancedloadbyusingdftcontrolleddvr
AT abdullahmohdnoor mitigationofvoltagesagcausedbyunbalancedloadbyusingdftcontrolleddvr
AT mohammadradzinurhanis mitigationofvoltagesagcausedbyunbalancedloadbyusingdftcontrolleddvr
AT ahmedmemonzubair mitigationofvoltagesagcausedbyunbalancedloadbyusingdftcontrolleddvr