Cuff-less continuous blood pressure monitoring system using pulse transit time techniques

This paper describes the development of a continuous cuff-less blood pressure system based on the pulse transit time (PTT) technique. In this study, PTT is defined by two different approaches denoted as PTT1 and PTT2. PTT1 is the time difference between the R-wave peak of the Electrocardiogram (ECG)...

Full description

Bibliographic Details
Main Authors: Wan Zaki, Wan Suhaimizan, Correia, Ricardo, Korposh, Serhiy, Hayes-Gill, Barrie R., Morgan, Stephen P
Format: Article
Language:English
Published: Penerbit UTHM 2016
Subjects:
Online Access:http://eprints.uthm.edu.my/4723/1/AJ%202020%20%2811%29.pdf
_version_ 1796869073059971072
author Wan Zaki, Wan Suhaimizan
Correia, Ricardo
Korposh, Serhiy
Hayes-Gill, Barrie R.
Morgan, Stephen P
author_facet Wan Zaki, Wan Suhaimizan
Correia, Ricardo
Korposh, Serhiy
Hayes-Gill, Barrie R.
Morgan, Stephen P
author_sort Wan Zaki, Wan Suhaimizan
collection UTHM
description This paper describes the development of a continuous cuff-less blood pressure system based on the pulse transit time (PTT) technique. In this study, PTT is defined by two different approaches denoted as PTT1 and PTT2. PTT1 is the time difference between the R-wave peak of the Electrocardiogram (ECG) and the peak of the Photoplethysmogram (PPG). PTT2 is the time difference between two peak PPG signals on same cardiac cycle at different positions on the body. The ECG is acquired on the chest using 3 lead electrodes and a reflection mode optical sensor is deployed on brachial artery and fingertip to monitor the PPGs. These data were synchronized using a National Instruments data acquisition card along with Matlab software for subsequent analysis. A wrist-type cuff-based blood pressure device was used to measure blood pressure on the right hand. Brachial blood pressure was measured on the upper left arm using oscillometric blood pressure monitor. Experiments were conducted by elevating the right hand at different position to investigate variability of PTT under the effects of hydrostatic pressure. Next the variability of PTT due to blood pressure changes during a Valsalva maneuver was investigated. The result shows that the PTT1 is inversely proportional to blood pressure in both experiments. Meanwhile, there is weak correlation between PTT2 and blood pressure measurement which suggests that by excluding the pre-ejection period (PEP) time in PTT calculation may reduce the accuracy of PTT for blood pressure measurement. In conclusion, PTT measurement between ECG and PPG signals has potential to be a reliable technique for cuff-less blood pressure measurement.
first_indexed 2024-03-05T21:49:21Z
format Article
id uthm.eprints-4723
institution Universiti Tun Hussein Onn Malaysia
language English
last_indexed 2024-03-05T21:49:21Z
publishDate 2016
publisher Penerbit UTHM
record_format dspace
spelling uthm.eprints-47232021-12-16T01:33:42Z http://eprints.uthm.edu.my/4723/ Cuff-less continuous blood pressure monitoring system using pulse transit time techniques Wan Zaki, Wan Suhaimizan Correia, Ricardo Korposh, Serhiy Hayes-Gill, Barrie R. Morgan, Stephen P TK7800-8360 Electronics This paper describes the development of a continuous cuff-less blood pressure system based on the pulse transit time (PTT) technique. In this study, PTT is defined by two different approaches denoted as PTT1 and PTT2. PTT1 is the time difference between the R-wave peak of the Electrocardiogram (ECG) and the peak of the Photoplethysmogram (PPG). PTT2 is the time difference between two peak PPG signals on same cardiac cycle at different positions on the body. The ECG is acquired on the chest using 3 lead electrodes and a reflection mode optical sensor is deployed on brachial artery and fingertip to monitor the PPGs. These data were synchronized using a National Instruments data acquisition card along with Matlab software for subsequent analysis. A wrist-type cuff-based blood pressure device was used to measure blood pressure on the right hand. Brachial blood pressure was measured on the upper left arm using oscillometric blood pressure monitor. Experiments were conducted by elevating the right hand at different position to investigate variability of PTT under the effects of hydrostatic pressure. Next the variability of PTT due to blood pressure changes during a Valsalva maneuver was investigated. The result shows that the PTT1 is inversely proportional to blood pressure in both experiments. Meanwhile, there is weak correlation between PTT2 and blood pressure measurement which suggests that by excluding the pre-ejection period (PEP) time in PTT calculation may reduce the accuracy of PTT for blood pressure measurement. In conclusion, PTT measurement between ECG and PPG signals has potential to be a reliable technique for cuff-less blood pressure measurement. Penerbit UTHM 2016 Article PeerReviewed text en http://eprints.uthm.edu.my/4723/1/AJ%202020%20%2811%29.pdf Wan Zaki, Wan Suhaimizan and Correia, Ricardo and Korposh, Serhiy and Hayes-Gill, Barrie R. and Morgan, Stephen P (2016) Cuff-less continuous blood pressure monitoring system using pulse transit time techniques. International Journal of Integrated Engineering, 8 (1). pp. 51-57. ISSN 2229-838X
spellingShingle TK7800-8360 Electronics
Wan Zaki, Wan Suhaimizan
Correia, Ricardo
Korposh, Serhiy
Hayes-Gill, Barrie R.
Morgan, Stephen P
Cuff-less continuous blood pressure monitoring system using pulse transit time techniques
title Cuff-less continuous blood pressure monitoring system using pulse transit time techniques
title_full Cuff-less continuous blood pressure monitoring system using pulse transit time techniques
title_fullStr Cuff-less continuous blood pressure monitoring system using pulse transit time techniques
title_full_unstemmed Cuff-less continuous blood pressure monitoring system using pulse transit time techniques
title_short Cuff-less continuous blood pressure monitoring system using pulse transit time techniques
title_sort cuff less continuous blood pressure monitoring system using pulse transit time techniques
topic TK7800-8360 Electronics
url http://eprints.uthm.edu.my/4723/1/AJ%202020%20%2811%29.pdf
work_keys_str_mv AT wanzakiwansuhaimizan cufflesscontinuousbloodpressuremonitoringsystemusingpulsetransittimetechniques
AT correiaricardo cufflesscontinuousbloodpressuremonitoringsystemusingpulsetransittimetechniques
AT korposhserhiy cufflesscontinuousbloodpressuremonitoringsystemusingpulsetransittimetechniques
AT hayesgillbarrier cufflesscontinuousbloodpressuremonitoringsystemusingpulsetransittimetechniques
AT morganstephenp cufflesscontinuousbloodpressuremonitoringsystemusingpulsetransittimetechniques