Comparing cooling energy between existing air-conditioning system and proposed design system

Air-conditioning (AC) system is typically used to remove the sensible and latent heat loads in buildings. It provides cool and dehumidified air to meet the occupants comfort and good indoor air quality (IAQ). Improper design and analysis of AC process resulted in high cooling energy and unsatisfied...

Full description

Bibliographic Details
Main Authors: Syazwan, M. M. Syafiq, Yusof, M. Z. M., Chang, C.K., Abdullah, M. D Amir
Format: Article
Language:English
Published: Trans Tech Publications 2015
Subjects:
Online Access:http://eprints.uthm.edu.my/6025/1/AJ%202018%20%28975%29%20Comparing%20cooling%20energy%20between%20existing%20air-conditioning%20system%20and%20proposed%20design%20system.pdf
_version_ 1796869294277001216
author Syazwan, M. M. Syafiq
Yusof, M. Z. M.
Chang, C.K.
Abdullah, M. D Amir
author_facet Syazwan, M. M. Syafiq
Yusof, M. Z. M.
Chang, C.K.
Abdullah, M. D Amir
author_sort Syazwan, M. M. Syafiq
collection UTHM
description Air-conditioning (AC) system is typically used to remove the sensible and latent heat loads in buildings. It provides cool and dehumidified air to meet the occupants comfort and good indoor air quality (IAQ). Improper design and analysis of AC process resulted in high cooling energy and unsatisfied indoor humidity level in tropical climate. The objective of this study is to identify the cooling energy in hotel restaurant by comparing the design with proper fresh air ventilation design. The hotel restaurant was designed with primary air unit (PAU) and air handling unit (AHU) as to remove sensible and latent loads. The performance of the AC system has been monitored and analysed using psychrometric chart. For the AC air side system, 296.2 kW of cooling energy was used in standard operation. An alternative design was proposed for the said hotel restaurant employing only one AHU, with a cooling capacity of 165.9 kW which was 43 % lower than the existing system. The difference in temperature, humidity ratio and air flow rate influenced the cooling energy for AC system.
first_indexed 2024-03-05T21:52:43Z
format Article
id uthm.eprints-6025
institution Universiti Tun Hussein Onn Malaysia
language English
last_indexed 2024-03-05T21:52:43Z
publishDate 2015
publisher Trans Tech Publications
record_format dspace
spelling uthm.eprints-60252022-01-26T02:33:22Z http://eprints.uthm.edu.my/6025/ Comparing cooling energy between existing air-conditioning system and proposed design system Syazwan, M. M. Syafiq Yusof, M. Z. M. Chang, C.K. Abdullah, M. D Amir TA170-171 Environmental engineering Air-conditioning (AC) system is typically used to remove the sensible and latent heat loads in buildings. It provides cool and dehumidified air to meet the occupants comfort and good indoor air quality (IAQ). Improper design and analysis of AC process resulted in high cooling energy and unsatisfied indoor humidity level in tropical climate. The objective of this study is to identify the cooling energy in hotel restaurant by comparing the design with proper fresh air ventilation design. The hotel restaurant was designed with primary air unit (PAU) and air handling unit (AHU) as to remove sensible and latent loads. The performance of the AC system has been monitored and analysed using psychrometric chart. For the AC air side system, 296.2 kW of cooling energy was used in standard operation. An alternative design was proposed for the said hotel restaurant employing only one AHU, with a cooling capacity of 165.9 kW which was 43 % lower than the existing system. The difference in temperature, humidity ratio and air flow rate influenced the cooling energy for AC system. Trans Tech Publications 2015 Article PeerReviewed text en http://eprints.uthm.edu.my/6025/1/AJ%202018%20%28975%29%20Comparing%20cooling%20energy%20between%20existing%20air-conditioning%20system%20and%20proposed%20design%20system.pdf Syazwan, M. M. Syafiq and Yusof, M. Z. M. and Chang, C.K. and Abdullah, M. D Amir (2015) Comparing cooling energy between existing air-conditioning system and proposed design system. Applied Mechanics and Materials, 699. pp. 834-839. ISSN 1662-7482
spellingShingle TA170-171 Environmental engineering
Syazwan, M. M. Syafiq
Yusof, M. Z. M.
Chang, C.K.
Abdullah, M. D Amir
Comparing cooling energy between existing air-conditioning system and proposed design system
title Comparing cooling energy between existing air-conditioning system and proposed design system
title_full Comparing cooling energy between existing air-conditioning system and proposed design system
title_fullStr Comparing cooling energy between existing air-conditioning system and proposed design system
title_full_unstemmed Comparing cooling energy between existing air-conditioning system and proposed design system
title_short Comparing cooling energy between existing air-conditioning system and proposed design system
title_sort comparing cooling energy between existing air conditioning system and proposed design system
topic TA170-171 Environmental engineering
url http://eprints.uthm.edu.my/6025/1/AJ%202018%20%28975%29%20Comparing%20cooling%20energy%20between%20existing%20air-conditioning%20system%20and%20proposed%20design%20system.pdf
work_keys_str_mv AT syazwanmmsyafiq comparingcoolingenergybetweenexistingairconditioningsystemandproposeddesignsystem
AT yusofmzm comparingcoolingenergybetweenexistingairconditioningsystemandproposeddesignsystem
AT changck comparingcoolingenergybetweenexistingairconditioningsystemandproposeddesignsystem
AT abdullahmdamir comparingcoolingenergybetweenexistingairconditioningsystemandproposeddesignsystem