Wide range analysis of ozone gas concentration in ultraviolet region

The purpose of this research is to investigate the development of optical gas sensor employing absorption spectroscopy technique for ozone concentration measurement. Additionally, wide range analysis has been conducted to improve range of ozone concentration measurement using ultraviolet light absor...

Full description

Bibliographic Details
Main Author: Yaacob, Maslina
Format: Thesis
Language:English
English
Published: 2016
Subjects:
Online Access:http://eprints.uthm.edu.my/647/1/24p%20MASLINA%20BINTI%20YAACOB.pdf
http://eprints.uthm.edu.my/647/2/MASLINA%20BINTI%20YAACOB%20COPYRIGHT%20DECLARATION.pdf
_version_ 1825636513851899904
author Yaacob, Maslina
author_facet Yaacob, Maslina
author_sort Yaacob, Maslina
collection UTHM
description The purpose of this research is to investigate the development of optical gas sensor employing absorption spectroscopy technique for ozone concentration measurement. Additionally, wide range analysis has been conducted to improve range of ozone concentration measurement using ultraviolet light absorption. Simulation of ozone absorption cross section in ultraviolet region was conducted via Spectralcalc.com® simulator. Simulation result for ozone absorption cross section was then verified by comparison with result from previous studies, showing small percentage of difference less than 3.05 %. In addition, the simulator was also used to investigate the effect of pressure and temperature on ozone absorption cross section. Simulation result showed ozone absorption cross section to exhibit negligible effect of pressure and temperature from 0.1 atm until 2.0 atm and from 293 K until 305 K, respectively. Next, path length of gas cell that suits with detection range of ozone monitor was determined through Spectralcalc.com® simulator. Finally, transmissive type gas cell is fabricated at optimum length of 10 cm. Based on the experiment results wide range analysis was conducted at 10 cm gas cell by consideration of less relative error of concentration. It was observed that wavelengths at 232 nm, 233 nm, 234 nm, 235 nm, 236 nm, 284 nm, 285 nm, 286 nm and 287 nm exhibit capability to measure ozone concentration using ultraviolet light absorption at high concentration value with wide range of concentration measurement from 619 ppm until 932 ppm. Of this, 285 nm was chosen due to its high resolution value at 17 ppm. The sensor exhibits fast response time and recovery time, both at 20 s. Peak of ozone absorption cross sections were observed in both experiment and simulation, located at 260.45 nm and 255.44 nm, respectively. Meanwhile, the values of peak of ozone absorption cross section were observed in experiment and simulation at 164.37 × 10-23 m2 molecule-1 and 114.86 × 10-23 m2 molecule-1, respectively. Significantly, this research has successfully demonstrated possibility of conducting wide-range analysis employing consideration of less relative error concentration. Particularly, vast improvement range of ozone concentration measurement has been achieved by wavelength selection which is far from the peak of ozone absorption cross section.
first_indexed 2024-03-05T21:37:56Z
format Thesis
id uthm.eprints-647
institution Universiti Tun Hussein Onn Malaysia
language English
English
last_indexed 2024-03-05T21:37:56Z
publishDate 2016
record_format dspace
spelling uthm.eprints-6472021-08-17T06:26:31Z http://eprints.uthm.edu.my/647/ Wide range analysis of ozone gas concentration in ultraviolet region Yaacob, Maslina QC350-467 Optics. Light The purpose of this research is to investigate the development of optical gas sensor employing absorption spectroscopy technique for ozone concentration measurement. Additionally, wide range analysis has been conducted to improve range of ozone concentration measurement using ultraviolet light absorption. Simulation of ozone absorption cross section in ultraviolet region was conducted via Spectralcalc.com® simulator. Simulation result for ozone absorption cross section was then verified by comparison with result from previous studies, showing small percentage of difference less than 3.05 %. In addition, the simulator was also used to investigate the effect of pressure and temperature on ozone absorption cross section. Simulation result showed ozone absorption cross section to exhibit negligible effect of pressure and temperature from 0.1 atm until 2.0 atm and from 293 K until 305 K, respectively. Next, path length of gas cell that suits with detection range of ozone monitor was determined through Spectralcalc.com® simulator. Finally, transmissive type gas cell is fabricated at optimum length of 10 cm. Based on the experiment results wide range analysis was conducted at 10 cm gas cell by consideration of less relative error of concentration. It was observed that wavelengths at 232 nm, 233 nm, 234 nm, 235 nm, 236 nm, 284 nm, 285 nm, 286 nm and 287 nm exhibit capability to measure ozone concentration using ultraviolet light absorption at high concentration value with wide range of concentration measurement from 619 ppm until 932 ppm. Of this, 285 nm was chosen due to its high resolution value at 17 ppm. The sensor exhibits fast response time and recovery time, both at 20 s. Peak of ozone absorption cross sections were observed in both experiment and simulation, located at 260.45 nm and 255.44 nm, respectively. Meanwhile, the values of peak of ozone absorption cross section were observed in experiment and simulation at 164.37 × 10-23 m2 molecule-1 and 114.86 × 10-23 m2 molecule-1, respectively. Significantly, this research has successfully demonstrated possibility of conducting wide-range analysis employing consideration of less relative error concentration. Particularly, vast improvement range of ozone concentration measurement has been achieved by wavelength selection which is far from the peak of ozone absorption cross section. 2016-06 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/647/1/24p%20MASLINA%20BINTI%20YAACOB.pdf text en http://eprints.uthm.edu.my/647/2/MASLINA%20BINTI%20YAACOB%20COPYRIGHT%20DECLARATION.pdf Yaacob, Maslina (2016) Wide range analysis of ozone gas concentration in ultraviolet region. Doctoral thesis, Universiti Teknologi Malaysia.
spellingShingle QC350-467 Optics. Light
Yaacob, Maslina
Wide range analysis of ozone gas concentration in ultraviolet region
title Wide range analysis of ozone gas concentration in ultraviolet region
title_full Wide range analysis of ozone gas concentration in ultraviolet region
title_fullStr Wide range analysis of ozone gas concentration in ultraviolet region
title_full_unstemmed Wide range analysis of ozone gas concentration in ultraviolet region
title_short Wide range analysis of ozone gas concentration in ultraviolet region
title_sort wide range analysis of ozone gas concentration in ultraviolet region
topic QC350-467 Optics. Light
url http://eprints.uthm.edu.my/647/1/24p%20MASLINA%20BINTI%20YAACOB.pdf
http://eprints.uthm.edu.my/647/2/MASLINA%20BINTI%20YAACOB%20COPYRIGHT%20DECLARATION.pdf
work_keys_str_mv AT yaacobmaslina widerangeanalysisofozonegasconcentrationinultravioletregion