Electromagnetic performances and main parameter sensitivity effect on unbalance magnetic flux in a New Single‑Phase FEFSM with segmental rotor
Three-phase field excitation flux switching motor (FEFSM) with salient rotor structure has been introduced with their advantages of rotor easy temperature elimination and controllable FEC magnetic flux. Yet, the salient rotor structure is found to lead a longer magnetic flux path between stator an...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Springer
2019
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/709/1/DNJ9733_c1d0c59a133346506ccb3c47f0e43f06.pdf |
_version_ | 1825636527019917312 |
---|---|
author | Omar, Mohd Fairoz Sulaiman, Erwan Ahmad, Md. Zarafi |
author_facet | Omar, Mohd Fairoz Sulaiman, Erwan Ahmad, Md. Zarafi |
author_sort | Omar, Mohd Fairoz |
collection | UTHM |
description | Three-phase field excitation flux switching motor (FEFSM) with salient rotor structure has been introduced with their advantages
of rotor easy temperature elimination and controllable FEC magnetic flux. Yet, the salient rotor structure is found to
lead a longer magnetic flux path between stator and rotor parts, producing a weak flux linkage along with low torque performances.
Hence, a new structure of single-phase FEFSM using segmental rotor with non-overlap windings is proposed with
advantages of shorter magnetic flux path, light weight and robust rotor structure. Analysis on fundamental magnetic flux
characteristics, armature and FEC magnetic flux linkages, cogging torque, back-Emf, various torque capabilities, refinement
of unbalance magnetic flux, and torque-power versus speed characteristics are conducted using 2D FEA through JMAG
Designer version 15. The results show that magnetic flux amplitude ratio has been improved by 41.2% while the highest
torque and power achieved are 1.45 Nm and 343.8 W, respectively. |
first_indexed | 2024-03-05T21:38:08Z |
format | Article |
id | uthm.eprints-709 |
institution | Universiti Tun Hussein Onn Malaysia |
language | English |
last_indexed | 2024-03-05T21:38:08Z |
publishDate | 2019 |
publisher | Springer |
record_format | dspace |
spelling | uthm.eprints-7092021-10-17T06:13:22Z http://eprints.uthm.edu.my/709/ Electromagnetic performances and main parameter sensitivity effect on unbalance magnetic flux in a New Single‑Phase FEFSM with segmental rotor Omar, Mohd Fairoz Sulaiman, Erwan Ahmad, Md. Zarafi TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers Three-phase field excitation flux switching motor (FEFSM) with salient rotor structure has been introduced with their advantages of rotor easy temperature elimination and controllable FEC magnetic flux. Yet, the salient rotor structure is found to lead a longer magnetic flux path between stator and rotor parts, producing a weak flux linkage along with low torque performances. Hence, a new structure of single-phase FEFSM using segmental rotor with non-overlap windings is proposed with advantages of shorter magnetic flux path, light weight and robust rotor structure. Analysis on fundamental magnetic flux characteristics, armature and FEC magnetic flux linkages, cogging torque, back-Emf, various torque capabilities, refinement of unbalance magnetic flux, and torque-power versus speed characteristics are conducted using 2D FEA through JMAG Designer version 15. The results show that magnetic flux amplitude ratio has been improved by 41.2% while the highest torque and power achieved are 1.45 Nm and 343.8 W, respectively. Springer 2019 Article PeerReviewed text en http://eprints.uthm.edu.my/709/1/DNJ9733_c1d0c59a133346506ccb3c47f0e43f06.pdf Omar, Mohd Fairoz and Sulaiman, Erwan and Ahmad, Md. Zarafi (2019) Electromagnetic performances and main parameter sensitivity effect on unbalance magnetic flux in a New Single‑Phase FEFSM with segmental rotor. Journal of Electrical Engineering & Technology, 14 (6). pp. 2333-2340. https://doi.org/10.1007/s42835-019-00254-2 |
spellingShingle | TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers Omar, Mohd Fairoz Sulaiman, Erwan Ahmad, Md. Zarafi Electromagnetic performances and main parameter sensitivity effect on unbalance magnetic flux in a New Single‑Phase FEFSM with segmental rotor |
title | Electromagnetic performances and main parameter sensitivity
effect on unbalance magnetic flux in a New Single‑Phase FEFSM
with segmental rotor |
title_full | Electromagnetic performances and main parameter sensitivity
effect on unbalance magnetic flux in a New Single‑Phase FEFSM
with segmental rotor |
title_fullStr | Electromagnetic performances and main parameter sensitivity
effect on unbalance magnetic flux in a New Single‑Phase FEFSM
with segmental rotor |
title_full_unstemmed | Electromagnetic performances and main parameter sensitivity
effect on unbalance magnetic flux in a New Single‑Phase FEFSM
with segmental rotor |
title_short | Electromagnetic performances and main parameter sensitivity
effect on unbalance magnetic flux in a New Single‑Phase FEFSM
with segmental rotor |
title_sort | electromagnetic performances and main parameter sensitivity effect on unbalance magnetic flux in a new single phase fefsm with segmental rotor |
topic | TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers |
url | http://eprints.uthm.edu.my/709/1/DNJ9733_c1d0c59a133346506ccb3c47f0e43f06.pdf |
work_keys_str_mv | AT omarmohdfairoz electromagneticperformancesandmainparametersensitivityeffectonunbalancemagneticfluxinanewsinglephasefefsmwithsegmentalrotor AT sulaimanerwan electromagneticperformancesandmainparametersensitivityeffectonunbalancemagneticfluxinanewsinglephasefefsmwithsegmentalrotor AT ahmadmdzarafi electromagneticperformancesandmainparametersensitivityeffectonunbalancemagneticfluxinanewsinglephasefefsmwithsegmentalrotor |