Water permeability of foamed concrete

This study focused on the compressive strength and water permeability of foamed concrete. Two types of foamed concrete mix with density 1500 kg/m3 and 1700 >5 kg/m were experimented Timber industrial ash (HA) were used as the partial cement replacement material, replacing 10% of Ordinary Port...

Full description

Bibliographic Details
Main Author: Wan Ibrahim, Mohd Haziman
Format: Thesis
Language:English
English
English
Published: 2004
Subjects:
Online Access:http://eprints.uthm.edu.my/8652/1/24p%20MOHD%20HAZIMAN%20WAN%20IBRAHIM.pdf
http://eprints.uthm.edu.my/8652/2/MOHD%20HAZIMAN%20WAN%20IBRAHIM%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/8652/3/MOHD%20HAZIMAN%20WAN%20IBRAHIM%20WATERMARK.pdf
_version_ 1796869806962507776
author Wan Ibrahim, Mohd Haziman
author_facet Wan Ibrahim, Mohd Haziman
author_sort Wan Ibrahim, Mohd Haziman
collection UTHM
description This study focused on the compressive strength and water permeability of foamed concrete. Two types of foamed concrete mix with density 1500 kg/m3 and 1700 >5 kg/m were experimented Timber industrial ash (HA) were used as the partial cement replacement material, replacing 10% of Ordinary Portland cement (OPC) in the mix design. The test cubes were 150 mm X 150 mm X150 mm size subjected to wet-cured and air cured for up to 28 days. The density, compressive strength development and water permeability of the TIA foamed concrete were determined to compare with the control mix (without TIA). The test method adopted based on DIN 1048 was used to determine the water permeability of foamed concrete at 28 days. Compressive strength was determined at 3 days, 7 days and 28 days. It was found that the air-cured specimens achieved a higher compressive strength and lower water permeability compared with the wet-cured specimens. Foamed concrete with 10% HA reduced the water permeability with a lower compressive strength at 28 days. The preliminary result indicated that HA has potential to reduce the water permeability of foamed concrete.
first_indexed 2024-03-05T22:00:16Z
format Thesis
id uthm.eprints-8652
institution Universiti Tun Hussein Onn Malaysia
language English
English
English
last_indexed 2024-03-05T22:00:16Z
publishDate 2004
record_format dspace
spelling uthm.eprints-86522023-05-02T02:13:07Z http://eprints.uthm.edu.my/8652/ Water permeability of foamed concrete Wan Ibrahim, Mohd Haziman TA Engineering (General). Civil engineering (General) TA401-492 Materials of engineering and construction. Mechanics of materials This study focused on the compressive strength and water permeability of foamed concrete. Two types of foamed concrete mix with density 1500 kg/m3 and 1700 >5 kg/m were experimented Timber industrial ash (HA) were used as the partial cement replacement material, replacing 10% of Ordinary Portland cement (OPC) in the mix design. The test cubes were 150 mm X 150 mm X150 mm size subjected to wet-cured and air cured for up to 28 days. The density, compressive strength development and water permeability of the TIA foamed concrete were determined to compare with the control mix (without TIA). The test method adopted based on DIN 1048 was used to determine the water permeability of foamed concrete at 28 days. Compressive strength was determined at 3 days, 7 days and 28 days. It was found that the air-cured specimens achieved a higher compressive strength and lower water permeability compared with the wet-cured specimens. Foamed concrete with 10% HA reduced the water permeability with a lower compressive strength at 28 days. The preliminary result indicated that HA has potential to reduce the water permeability of foamed concrete. 2004-04 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/8652/1/24p%20MOHD%20HAZIMAN%20WAN%20IBRAHIM.pdf text en http://eprints.uthm.edu.my/8652/2/MOHD%20HAZIMAN%20WAN%20IBRAHIM%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/8652/3/MOHD%20HAZIMAN%20WAN%20IBRAHIM%20WATERMARK.pdf Wan Ibrahim, Mohd Haziman (2004) Water permeability of foamed concrete. Masters thesis, Kolej Universiti Teknologi Tun Hussein Onn.
spellingShingle TA Engineering (General). Civil engineering (General)
TA401-492 Materials of engineering and construction. Mechanics of materials
Wan Ibrahim, Mohd Haziman
Water permeability of foamed concrete
title Water permeability of foamed concrete
title_full Water permeability of foamed concrete
title_fullStr Water permeability of foamed concrete
title_full_unstemmed Water permeability of foamed concrete
title_short Water permeability of foamed concrete
title_sort water permeability of foamed concrete
topic TA Engineering (General). Civil engineering (General)
TA401-492 Materials of engineering and construction. Mechanics of materials
url http://eprints.uthm.edu.my/8652/1/24p%20MOHD%20HAZIMAN%20WAN%20IBRAHIM.pdf
http://eprints.uthm.edu.my/8652/2/MOHD%20HAZIMAN%20WAN%20IBRAHIM%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/8652/3/MOHD%20HAZIMAN%20WAN%20IBRAHIM%20WATERMARK.pdf
work_keys_str_mv AT wanibrahimmohdhaziman waterpermeabilityoffoamedconcrete