Influence of Crisscross Fiberglass Strip on Axial Compressive Strength of Lightweight Foamed Concrete

Concrete use as a building component is already associated with the global construction sector. Since extensive research on concrete has been conducted for many years, there is a growing interest among researchers to conduct studies to increase the capacity of concrete for use in the building secto...

Full description

Bibliographic Details
Main Authors: Othuman Mydin, Md Azree, Khalid, Mohamad Sukeri, Omar, Roshartini, Mohammed Najm, Hadee, Mahmood Abdal Qaidi, Shaker, Awoyera, Paul Oluwaseun
Format: Article
Language:English
Published: Semarak Ilmu 2023
Subjects:
Online Access:http://eprints.uthm.edu.my/8764/1/J15724_965cc04ee96c1c5d8c46d808537e5ae5.pdf
_version_ 1825710635105648640
author Othuman Mydin, Md Azree
Khalid, Mohamad Sukeri
Omar, Roshartini
Mohammed Najm, Hadee
Mahmood Abdal Qaidi, Shaker
Awoyera, Paul Oluwaseun
author_facet Othuman Mydin, Md Azree
Khalid, Mohamad Sukeri
Omar, Roshartini
Mohammed Najm, Hadee
Mahmood Abdal Qaidi, Shaker
Awoyera, Paul Oluwaseun
author_sort Othuman Mydin, Md Azree
collection UTHM
description Concrete use as a building component is already associated with the global construction sector. Since extensive research on concrete has been conducted for many years, there is a growing interest among researchers to conduct studies to increase the capacity of concrete for use in the building sector. Lightweight foamed concrete is one of the cutting-edge solutions developed for lighter and more sustainable buildings. Although this type of concrete has several benefits, its strength is still viewed as being inferior to that of regular concrete. By limiting the LFC with a crisscross fiberglass strip, the authors of this work will demonstrate improvements in LFC behaviour in terms of its compressive strength (CFS). To examine its improvements, 3 different LFC densities were cast and contained with 1 to 3 layers of 160 g/m2 CFS. For this test, the cementto-sand ratio was fixed at 1.1:5, and the water content was set at 0.45. The results revealed that the compressive strength of LFC confined with 1 to 3 layers of CFS increased by 153%, 97% and 102% were acquired for 600, 1100 and 1600 kg/m3 densities respectively. This demonstrates that the number of layers used affects how positively the confinement of CFS affects the compressive behaviour of LFC.
first_indexed 2024-03-05T22:00:36Z
format Article
id uthm.eprints-8764
institution Universiti Tun Hussein Onn Malaysia
language English
last_indexed 2024-03-05T22:00:36Z
publishDate 2023
publisher Semarak Ilmu
record_format dspace
spelling uthm.eprints-87642023-05-16T02:48:10Z http://eprints.uthm.edu.my/8764/ Influence of Crisscross Fiberglass Strip on Axial Compressive Strength of Lightweight Foamed Concrete Othuman Mydin, Md Azree Khalid, Mohamad Sukeri Omar, Roshartini Mohammed Najm, Hadee Mahmood Abdal Qaidi, Shaker Awoyera, Paul Oluwaseun TA Engineering (General). Civil engineering (General) Concrete use as a building component is already associated with the global construction sector. Since extensive research on concrete has been conducted for many years, there is a growing interest among researchers to conduct studies to increase the capacity of concrete for use in the building sector. Lightweight foamed concrete is one of the cutting-edge solutions developed for lighter and more sustainable buildings. Although this type of concrete has several benefits, its strength is still viewed as being inferior to that of regular concrete. By limiting the LFC with a crisscross fiberglass strip, the authors of this work will demonstrate improvements in LFC behaviour in terms of its compressive strength (CFS). To examine its improvements, 3 different LFC densities were cast and contained with 1 to 3 layers of 160 g/m2 CFS. For this test, the cementto-sand ratio was fixed at 1.1:5, and the water content was set at 0.45. The results revealed that the compressive strength of LFC confined with 1 to 3 layers of CFS increased by 153%, 97% and 102% were acquired for 600, 1100 and 1600 kg/m3 densities respectively. This demonstrates that the number of layers used affects how positively the confinement of CFS affects the compressive behaviour of LFC. Semarak Ilmu 2023 Article PeerReviewed text en http://eprints.uthm.edu.my/8764/1/J15724_965cc04ee96c1c5d8c46d808537e5ae5.pdf Othuman Mydin, Md Azree and Khalid, Mohamad Sukeri and Omar, Roshartini and Mohammed Najm, Hadee and Mahmood Abdal Qaidi, Shaker and Awoyera, Paul Oluwaseun (2023) Influence of Crisscross Fiberglass Strip on Axial Compressive Strength of Lightweight Foamed Concrete. Journal of Advanced Research in Applied Sciences and Engineering Technology, 29 (2). pp. 35-144. ISSN 2462-1943 https://doi.org/10.37934/araset.29.2.135144
spellingShingle TA Engineering (General). Civil engineering (General)
Othuman Mydin, Md Azree
Khalid, Mohamad Sukeri
Omar, Roshartini
Mohammed Najm, Hadee
Mahmood Abdal Qaidi, Shaker
Awoyera, Paul Oluwaseun
Influence of Crisscross Fiberglass Strip on Axial Compressive Strength of Lightweight Foamed Concrete
title Influence of Crisscross Fiberglass Strip on Axial Compressive Strength of Lightweight Foamed Concrete
title_full Influence of Crisscross Fiberglass Strip on Axial Compressive Strength of Lightweight Foamed Concrete
title_fullStr Influence of Crisscross Fiberglass Strip on Axial Compressive Strength of Lightweight Foamed Concrete
title_full_unstemmed Influence of Crisscross Fiberglass Strip on Axial Compressive Strength of Lightweight Foamed Concrete
title_short Influence of Crisscross Fiberglass Strip on Axial Compressive Strength of Lightweight Foamed Concrete
title_sort influence of crisscross fiberglass strip on axial compressive strength of lightweight foamed concrete
topic TA Engineering (General). Civil engineering (General)
url http://eprints.uthm.edu.my/8764/1/J15724_965cc04ee96c1c5d8c46d808537e5ae5.pdf
work_keys_str_mv AT othumanmydinmdazree influenceofcrisscrossfiberglassstriponaxialcompressivestrengthoflightweightfoamedconcrete
AT khalidmohamadsukeri influenceofcrisscrossfiberglassstriponaxialcompressivestrengthoflightweightfoamedconcrete
AT omarroshartini influenceofcrisscrossfiberglassstriponaxialcompressivestrengthoflightweightfoamedconcrete
AT mohammednajmhadee influenceofcrisscrossfiberglassstriponaxialcompressivestrengthoflightweightfoamedconcrete
AT mahmoodabdalqaidishaker influenceofcrisscrossfiberglassstriponaxialcompressivestrengthoflightweightfoamedconcrete
AT awoyerapauloluwaseun influenceofcrisscrossfiberglassstriponaxialcompressivestrengthoflightweightfoamedconcrete