Field Measurement of Air Velocity and Temperature Factors that Influence the Thermal Comfort in Shuttle Bus

Good public transportation that can offer a pleasant peaceful and relaxing environment is necessary for improving people's interest in using it. Thermal comfort is determined in this study by measuring the air velocity and temperature of the air-conditioning from the outlet. Both data are take...

Full description

Bibliographic Details
Main Authors: Nur Yunus, Faizal Amin, Mohd Salleh, Zuan Azhary, Rahim, Mohd Bekri, Mohd Affand, Haryanti, Kamis, Arasinah, Syazwan Mustafa, Mohd Syafiq
Format: Article
Language:English
Published: Semarak Ilmu
Subjects:
Online Access:http://eprints.uthm.edu.my/8782/1/J15767_8fd8c0d906e8ceac85a5101d4452de91.pdf
_version_ 1825710638652981248
author Nur Yunus, Faizal Amin
Mohd Salleh, Zuan Azhary
Rahim, Mohd Bekri
Mohd Affand, Haryanti
Kamis, Arasinah
Syazwan Mustafa, Mohd Syafiq
author_facet Nur Yunus, Faizal Amin
Mohd Salleh, Zuan Azhary
Rahim, Mohd Bekri
Mohd Affand, Haryanti
Kamis, Arasinah
Syazwan Mustafa, Mohd Syafiq
author_sort Nur Yunus, Faizal Amin
collection UTHM
description Good public transportation that can offer a pleasant peaceful and relaxing environment is necessary for improving people's interest in using it. Thermal comfort is determined in this study by measuring the air velocity and temperature of the air-conditioning from the outlet. Both data are taken using a digital anemometer and thermocouple with three replications for reproducibility. For data collection, a 10-row shuttle bus was held immobile for 30 minutes. According to the data, outlet 5 received the highest air velocity and the lowest temperature, at 9.12 ms-1 and 13.6 °C, respectively. It was also discovered that the design of the air-conditioning ducting impacts the reachability of cooled air to the farthest outlets, adversely affecting the target cool temperature and passenger comfortability. It is suggested that in order to promote the attractiveness of public transportation, the inner bus compartment and air-conditioning system in hot countries should prioritise thermal comfort.
first_indexed 2024-03-05T22:00:39Z
format Article
id uthm.eprints-8782
institution Universiti Tun Hussein Onn Malaysia
language English
last_indexed 2024-03-05T22:00:39Z
publisher Semarak Ilmu
record_format dspace
spelling uthm.eprints-87822023-06-12T07:17:05Z http://eprints.uthm.edu.my/8782/ Field Measurement of Air Velocity and Temperature Factors that Influence the Thermal Comfort in Shuttle Bus Nur Yunus, Faizal Amin Mohd Salleh, Zuan Azhary Rahim, Mohd Bekri Mohd Affand, Haryanti Kamis, Arasinah Syazwan Mustafa, Mohd Syafiq TJ Mechanical engineering and machinery Good public transportation that can offer a pleasant peaceful and relaxing environment is necessary for improving people's interest in using it. Thermal comfort is determined in this study by measuring the air velocity and temperature of the air-conditioning from the outlet. Both data are taken using a digital anemometer and thermocouple with three replications for reproducibility. For data collection, a 10-row shuttle bus was held immobile for 30 minutes. According to the data, outlet 5 received the highest air velocity and the lowest temperature, at 9.12 ms-1 and 13.6 °C, respectively. It was also discovered that the design of the air-conditioning ducting impacts the reachability of cooled air to the farthest outlets, adversely affecting the target cool temperature and passenger comfortability. It is suggested that in order to promote the attractiveness of public transportation, the inner bus compartment and air-conditioning system in hot countries should prioritise thermal comfort. Semarak Ilmu Article PeerReviewed text en http://eprints.uthm.edu.my/8782/1/J15767_8fd8c0d906e8ceac85a5101d4452de91.pdf Nur Yunus, Faizal Amin and Mohd Salleh, Zuan Azhary and Rahim, Mohd Bekri and Mohd Affand, Haryanti and Kamis, Arasinah and Syazwan Mustafa, Mohd Syafiq Field Measurement of Air Velocity and Temperature Factors that Influence the Thermal Comfort in Shuttle Bus. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 101 (3). pp. 164-171. ISSN 2289-7879 https://doi.org/10.37934/arfmts.101.2.164171
spellingShingle TJ Mechanical engineering and machinery
Nur Yunus, Faizal Amin
Mohd Salleh, Zuan Azhary
Rahim, Mohd Bekri
Mohd Affand, Haryanti
Kamis, Arasinah
Syazwan Mustafa, Mohd Syafiq
Field Measurement of Air Velocity and Temperature Factors that Influence the Thermal Comfort in Shuttle Bus
title Field Measurement of Air Velocity and Temperature Factors that Influence the Thermal Comfort in Shuttle Bus
title_full Field Measurement of Air Velocity and Temperature Factors that Influence the Thermal Comfort in Shuttle Bus
title_fullStr Field Measurement of Air Velocity and Temperature Factors that Influence the Thermal Comfort in Shuttle Bus
title_full_unstemmed Field Measurement of Air Velocity and Temperature Factors that Influence the Thermal Comfort in Shuttle Bus
title_short Field Measurement of Air Velocity and Temperature Factors that Influence the Thermal Comfort in Shuttle Bus
title_sort field measurement of air velocity and temperature factors that influence the thermal comfort in shuttle bus
topic TJ Mechanical engineering and machinery
url http://eprints.uthm.edu.my/8782/1/J15767_8fd8c0d906e8ceac85a5101d4452de91.pdf
work_keys_str_mv AT nuryunusfaizalamin fieldmeasurementofairvelocityandtemperaturefactorsthatinfluencethethermalcomfortinshuttlebus
AT mohdsallehzuanazhary fieldmeasurementofairvelocityandtemperaturefactorsthatinfluencethethermalcomfortinshuttlebus
AT rahimmohdbekri fieldmeasurementofairvelocityandtemperaturefactorsthatinfluencethethermalcomfortinshuttlebus
AT mohdaffandharyanti fieldmeasurementofairvelocityandtemperaturefactorsthatinfluencethethermalcomfortinshuttlebus
AT kamisarasinah fieldmeasurementofairvelocityandtemperaturefactorsthatinfluencethethermalcomfortinshuttlebus
AT syazwanmustafamohdsyafiq fieldmeasurementofairvelocityandtemperaturefactorsthatinfluencethethermalcomfortinshuttlebus