Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface

Myocardial infarction (MI) is highly related to cardiac arrest leading to death and organ damage. Radiological techniques and electrocardiography have been used as preliminary tests to diagnose MI, however, these techniques are not sensitive enough for early-stage detection. A blood biomarker-based...

Full description

Bibliographic Details
Main Authors: Hu, Hui, Gopinath, Subash C. B., Ismail, Zool H., Chen, Yeng, Pandian, K., Velusamy, Palaniyandi
Format: Article
Published: John Wiley and Sons Inc 2023
Subjects:
_version_ 1811132159313838080
author Hu, Hui
Gopinath, Subash C. B.
Ismail, Zool H.
Chen, Yeng
Pandian, K.
Velusamy, Palaniyandi
author_facet Hu, Hui
Gopinath, Subash C. B.
Ismail, Zool H.
Chen, Yeng
Pandian, K.
Velusamy, Palaniyandi
author_sort Hu, Hui
collection ePrints
description Myocardial infarction (MI) is highly related to cardiac arrest leading to death and organ damage. Radiological techniques and electrocardiography have been used as preliminary tests to diagnose MI, however, these techniques are not sensitive enough for early-stage detection. A blood biomarker-based diagnosis is an immediate solution, and due to the high correlation of troponin with MI, it has been considered to be a gold-standard biomarker. In the present research, the cardiac biomarker troponin I (cTnI) was detected on an interdigitated electrode sensor with various surface interfaces. To detect cTnI, a capture aptamer-conjugated gold nanoparticle probe and detection antibody probe were utilized and compared through an alternating sandwich pattern. The surface metal oxide morphology of the developed sensor was proven by microscopic assessments. The limit of detection with the aptamer-gold-cTnI-antibody sandwich pattern was 100 aM, while it was 1 fM with antibody-gold-cTnI-aptamer, representing 10-fold differences. Further, the high performance of the sensor was confirmed by selective cTnI determination in serum, exhibiting superior nonfouling. These methods of determination provide options for generating novel assays for diagnosing MI.
first_indexed 2024-09-23T23:58:23Z
format Article
id utm.eprints-105565
institution Universiti Teknologi Malaysia - ePrints
last_indexed 2024-09-23T23:58:23Z
publishDate 2023
publisher John Wiley and Sons Inc
record_format dspace
spelling utm.eprints-1055652024-05-06T06:24:40Z http://eprints.utm.my/105565/ Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface Hu, Hui Gopinath, Subash C. B. Ismail, Zool H. Chen, Yeng Pandian, K. Velusamy, Palaniyandi T Technology (General) Myocardial infarction (MI) is highly related to cardiac arrest leading to death and organ damage. Radiological techniques and electrocardiography have been used as preliminary tests to diagnose MI, however, these techniques are not sensitive enough for early-stage detection. A blood biomarker-based diagnosis is an immediate solution, and due to the high correlation of troponin with MI, it has been considered to be a gold-standard biomarker. In the present research, the cardiac biomarker troponin I (cTnI) was detected on an interdigitated electrode sensor with various surface interfaces. To detect cTnI, a capture aptamer-conjugated gold nanoparticle probe and detection antibody probe were utilized and compared through an alternating sandwich pattern. The surface metal oxide morphology of the developed sensor was proven by microscopic assessments. The limit of detection with the aptamer-gold-cTnI-antibody sandwich pattern was 100 aM, while it was 1 fM with antibody-gold-cTnI-aptamer, representing 10-fold differences. Further, the high performance of the sensor was confirmed by selective cTnI determination in serum, exhibiting superior nonfouling. These methods of determination provide options for generating novel assays for diagnosing MI. John Wiley and Sons Inc 2023 Article PeerReviewed Hu, Hui and Gopinath, Subash C. B. and Ismail, Zool H. and Chen, Yeng and Pandian, K. and Velusamy, Palaniyandi (2023) Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface. Biotechnology and Applied Biochemistry, 70 (2). pp. 581-591. ISSN 0885-4513 http://dx.doi.org/10.1002/bab.2380 DOI : 10.1002/bab.2380
spellingShingle T Technology (General)
Hu, Hui
Gopinath, Subash C. B.
Ismail, Zool H.
Chen, Yeng
Pandian, K.
Velusamy, Palaniyandi
Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface
title Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface
title_full Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface
title_fullStr Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface
title_full_unstemmed Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface
title_short Cardiovascular biomarker troponin I biosensor: Aptamer-gold-antibody hybrid on a metal oxide surface
title_sort cardiovascular biomarker troponin i biosensor aptamer gold antibody hybrid on a metal oxide surface
topic T Technology (General)
work_keys_str_mv AT huhui cardiovascularbiomarkertroponinibiosensoraptamergoldantibodyhybridonametaloxidesurface
AT gopinathsubashcb cardiovascularbiomarkertroponinibiosensoraptamergoldantibodyhybridonametaloxidesurface
AT ismailzoolh cardiovascularbiomarkertroponinibiosensoraptamergoldantibodyhybridonametaloxidesurface
AT chenyeng cardiovascularbiomarkertroponinibiosensoraptamergoldantibodyhybridonametaloxidesurface
AT pandiank cardiovascularbiomarkertroponinibiosensoraptamergoldantibodyhybridonametaloxidesurface
AT velusamypalaniyandi cardiovascularbiomarkertroponinibiosensoraptamergoldantibodyhybridonametaloxidesurface