Strength behaviour of column studs in prefabricated wall panels using cold-formed steel
A full-scale experimental study on the strength behaviour of individual studs and column studs in a prefabricated wall panel is presented in this report. The individual stud and the panel are made of cold-formed steel sections with a dimension of 3 m height, and 3.15 m height and 1.5 m width respect...
Main Author: | Jaffar, Siti Rahayu |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2010
|
Subjects: | |
Online Access: | http://eprints.utm.my/11230/1/SitiRahayuJaffarMFKA2010.pdf |
Similar Items
-
Strength and behaviour of thin-walled cold-formed structural steel box columns
by: Chiew, Sing Ping., et al.
Published: (2008) -
Experimental study of cold-formed steel columns with openings
by: Mohd Aizat Herman, Mohd Rosdi
Published: (2019) -
Axially loaded of cold-formed steel columns with opening
by: Nurul Atikah, Zulkipli
Published: (2017) -
Seismic Performance Of A Double-Storey Prefabricated Cold-Formed Steel Structure As Post-Disaster Temporary Housing
by: Wong, Jia Hui
Published: (2021) -
Axial compression behaviour of full-scale prefabricated wood-wool wall panel
by: Md Noh, Mohammad Soffi, et al.
Published: (2020)