Combustion of refuse derived fuel (RDF) in a fluidized bed combustor

The combustion characteristics of refuse derived fuel (RDF) in a fluidized bed have been studied. The gross heating value (GHV) of the RDF was 14.43 MJ/kg with moisture content of 25% by weight. Parameters of interest for sustainable bed combustion were the fluidization number and primary air factor...

Full description

Bibliographic Details
Main Authors: Johari, Anwar, Hashim, Haslenda, Rozainee, M., Mutahharah, M. M.
Format: Conference or Workshop Item
Published: 2009
Subjects:
_version_ 1796855473156128768
author Johari, Anwar
Hashim, Haslenda
Rozainee, M.
Mutahharah, M. M.
author_facet Johari, Anwar
Hashim, Haslenda
Rozainee, M.
Mutahharah, M. M.
author_sort Johari, Anwar
collection ePrints
description The combustion characteristics of refuse derived fuel (RDF) in a fluidized bed have been studied. The gross heating value (GHV) of the RDF was 14.43 MJ/kg with moisture content of 25% by weight. Parameters of interest for sustainable bed combustion were the fluidization number and primary air factor. The study was performed in a rectangular fluidized bed combustor with dimensions of 0.3 m in width, 0.7 m in length and 2 m in height. Sand with mean particle size of 0.34 mm was used as a fluidization medium. The sand bed height was at 0.3 m above the standpipes air distributor. The range of fluidization number under investigation was 5-7 Umf in which 5 Umf was found to be the optimum. The study was continued for the determination of the optimum primary air factor with the selected range of primary air factors being 0.6, 0.8, 1.0 and 1.2 in experiments conducted at 5 Umf. The final results showed that the optimum primary air factor was at 0.8. An energy balance was also performed to determine the thermal efficiency of the combustion. It was concluded that the thermal efficiency depended on the bed temperature and the primary air factor being used.
first_indexed 2024-03-05T18:29:00Z
format Conference or Workshop Item
id utm.eprints-14988
institution Universiti Teknologi Malaysia - ePrints
last_indexed 2024-03-05T18:29:00Z
publishDate 2009
record_format dspace
spelling utm.eprints-149882020-07-07T04:59:44Z http://eprints.utm.my/14988/ Combustion of refuse derived fuel (RDF) in a fluidized bed combustor Johari, Anwar Hashim, Haslenda Rozainee, M. Mutahharah, M. M. QD Chemistry The combustion characteristics of refuse derived fuel (RDF) in a fluidized bed have been studied. The gross heating value (GHV) of the RDF was 14.43 MJ/kg with moisture content of 25% by weight. Parameters of interest for sustainable bed combustion were the fluidization number and primary air factor. The study was performed in a rectangular fluidized bed combustor with dimensions of 0.3 m in width, 0.7 m in length and 2 m in height. Sand with mean particle size of 0.34 mm was used as a fluidization medium. The sand bed height was at 0.3 m above the standpipes air distributor. The range of fluidization number under investigation was 5-7 Umf in which 5 Umf was found to be the optimum. The study was continued for the determination of the optimum primary air factor with the selected range of primary air factors being 0.6, 0.8, 1.0 and 1.2 in experiments conducted at 5 Umf. The final results showed that the optimum primary air factor was at 0.8. An energy balance was also performed to determine the thermal efficiency of the combustion. It was concluded that the thermal efficiency depended on the bed temperature and the primary air factor being used. 2009 Conference or Workshop Item PeerReviewed Johari, Anwar and Hashim, Haslenda and Rozainee, M. and Mutahharah, M. M. (2009) Combustion of refuse derived fuel (RDF) in a fluidized bed combustor. In: International Seminar on Advances in Renewable Energy Technology, 2009, Uniten, Kajang. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:79095
spellingShingle QD Chemistry
Johari, Anwar
Hashim, Haslenda
Rozainee, M.
Mutahharah, M. M.
Combustion of refuse derived fuel (RDF) in a fluidized bed combustor
title Combustion of refuse derived fuel (RDF) in a fluidized bed combustor
title_full Combustion of refuse derived fuel (RDF) in a fluidized bed combustor
title_fullStr Combustion of refuse derived fuel (RDF) in a fluidized bed combustor
title_full_unstemmed Combustion of refuse derived fuel (RDF) in a fluidized bed combustor
title_short Combustion of refuse derived fuel (RDF) in a fluidized bed combustor
title_sort combustion of refuse derived fuel rdf in a fluidized bed combustor
topic QD Chemistry
work_keys_str_mv AT joharianwar combustionofrefusederivedfuelrdfinafluidizedbedcombustor
AT hashimhaslenda combustionofrefusederivedfuelrdfinafluidizedbedcombustor
AT rozaineem combustionofrefusederivedfuelrdfinafluidizedbedcombustor
AT mutahharahmm combustionofrefusederivedfuelrdfinafluidizedbedcombustor